9LG0612P4S001 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 299.9 Pa maximum pressure stated for this model. It also lists a 60*60*25 mm size specified in the upload data. Review housing geometry for project specification.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60*60*25 |
| Max.Air Flow(m³/h) | 83.98 |
| Max.Pressure(Pa) | 299.9 |
| Input Power(W) | 8.04 |
| Speed(rpm) | 11000 |
| Noise(db) | 53 |
Designed around the cooling needs of data centers and communication assembly, the SANYO DENKI 9LG0612P4S001 provides a DC axial fan format for OEM assembly integration.
The listed 12 V supply and 8.04 W input give electrical designers a defined basis for power and interface planning.
Its axial-flow arrangement carries a relatively large air volume along the motor axis, making it suitable for low-to-moderate system resistance.
This helps system developers translate ventilation flow into lower component temperature, steadier duty and a more repeatable assembly design. Preserve the specified ventilation flow direction during assembly. Review the approved electrical interface for the complete suffix. Validate sound and temperature in the finished enclosure.
For assembly in servers and data-communication hardware, SANYO DENKI 9LG0612P4S001 acts as a heat removal component that cools computing and network assemblies. Forced-air heat removal contributes to assembly availability during long duty cycles and repeated load changes.
Installation serving power supplies, inverters and control cabinets can integrate SANYO DENKI 9LG0612P4S001; the unit cools power modules and controls. Forced-air thermal management helps maintain installation availability during long duty cycles and repeated load changes.
As part of industrial automation installation, SANYO DENKI 9LG0612P4S001 performs a defined thermal control task and ventilates drives and production electronics. Maintaining clear inlet and outlet space helps the installed unit realize the expected thermal control benefit.
The 9LG0612P4S001 is positioned for medical and laboratory instruments, helping the completed assembly cools enclosed instrument electronics. Forced-air forced-air cooling enables assembly availability during long duty cycles and repeated load changes.
The upload row lists 53 dB. Confirm the measurement condition and compare noise at the intended operating point.
No guaranteed lead time is provided in the supplied sources. Confirm current stock, required quantity, production schedule, and shipping date with the supplier.
The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.
It may be evaluated for high-reliability cooling using the supplied parameters, but duty cycle, redundancy, ambient limits, and protection must be confirmed at system level.
Check electrical supply, mounting clearance, fasteners, airflow direction, guards, wiring, and access for service before installation.
No quantified cost-saving claim is supplied for this exact item. Compare energy use, controls, service needs, and purchase cost using the required duty point.