For thermal management in servers, UPS systems, and telecom equipment, the 9LG0624P4S001 provides a 24 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 11000 rpm is the model's most prominent operating value. Review its supply requirement during controller selection. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60*60*25 |
| Max.Air Flow(m³/h) | 84 |
| Max.Pressure(Pa) | 300 |
| Input Power(W) | 8.16 |
| Speed(rpm) | 11000 |
| Noise(db) | 53 |
SANYO DENKI positions 9LG0624P4S001 as a DC axial fan for telecom cabinets and network equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.
With up to 84 m3/h airflow and 300 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.
Check startup demand against the power supply. It supports stable operation across the intended load cycle. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
The San Ace 9LG0624P4S001 supports thermal management in telecom cabinets and radio-access equipment. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
For routers, switches and edge-network hardware, 9LG0624P4S001 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.