Sanyo Denki configures 9LG0824P4G001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 80 × 80 × 25 mm dimensions. A listed input of 3.36 W is the notable efficiency-related parameter. The recorded motor input should guide thermal validation. Confirm environmental protection for the ordered version.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80*80*25 |
| Max.Air Flow(m³/h) | 92.31 |
| Max.Pressure(Pa) | 97.1 |
| Input Power(W) | 3.36 |
| Speed(rpm) | 5500 |
| Noise(db) | 43 |
9LG0824P4G001 brings San Ace DC axial fan cooling to telecom cabinets and network equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
Its 92.31 m3/h maximum airflow supports rapid air exchange, while 97.1 Pa pressure capability helps overcome resistance within the finished equipment. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Qualify performance with the production guard. It also creates a clearer thermal approval record. Confirm the final fan curve in the assembled equipment.
SANYO DENKI 9LG0824P4G001 serves telecom cabinets and radio-access equipment that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It supports reliable OEM equipment cooling.
9LG0824P4G001 is suitable for routers, switches and edge-network hardware. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It supports reliable OEM equipment cooling. Selection should follow the approved full model code.
Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.
The worksheet lists 97.1 Pa. Use the official curve to match it to system resistance.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.
The reference lists IP20. Confirm that the exact ordered suffix carries the required environmental rating.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.