Sanyo Denki configures 9RA0824P4G001 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 80 × 80 × 25 mm dimensions. A listed input of 2.64 W is the notable efficiency-related parameter. Review its thermal-duty record during system-resistance review. Validate mounting and wiring from the model drawing.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80*80*25 |
| Max.Air Flow(m³/h) | 84 |
| Max.Pressure(Pa) | 83 |
| Input Power(W) | 2.64 |
| Speed(rpm) | 5000 |
| Noise(db) | 37 |
SANYO DENKI positions 9RA0824P4G001 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.
Its 84 m3/h maximum airflow supports rapid air exchange, while 83 Pa pressure capability helps overcome resistance within the finished equipment. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.
Review grille loss at the required duty point. It supports a clear fan specification for future servicing. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
SANYO DENKI 9RA0824P4G001 serves server chassis and computing nodes that operate with sustained internal heat. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. The application supports stable equipment service.
9RA0824P4G001 is suitable for storage arrays and data appliances. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 9RA0824P4G001 supports thermal management in network and other ICT hardware. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Its 24 VDC rating and documented a listed input of 2.64 w is the notable efficiency-related parameter. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 2.64 W. Check supply capacity and operating conditions before commissioning.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
Check its 80 × 80 × 25 mm size, 84 m³/h airflow, 83 Pa pressure, mounting points, airflow direction, and system resistance.