Sanyo Denki 9RA0924F40011 is a 24 VDC DC axial fan in a 92 × 92 × 25 mm format for servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. A listed noise figure of 27 dB is the key differentiating parameter. Check duty point matching dimensional envelope. Focus: duty point matching dimensional envelope.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92*92*25 |
| Max.Air Flow(m³/h) | 73.27 |
| Max.Pressure(Pa) | 34.9 |
| Input Power(W) | 1.44 |
| Speed(rpm) | 2850 |
| Noise(db) | 27 |
The SANYO DENKI 9RA0924F40011 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.
The rated peak airflow of 73.27 m3/h combines with 34.9 Pa pressure capability to support useful flow after installation losses are considered. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Measure installed sound in the final cabinet. The review links cooling performance to the approved BOM. Confirm the final fan curve in the assembled equipment.
For server chassis and computing nodes, 9RA0924F40011 provides a dedicated forced-air cooling path. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
SANYO DENKI 9RA0924F40011 serves storage arrays and data appliances that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. This helps maintain dependable equipment operation.
9RA0924F40011 is suitable for network and other ICT hardware. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. This helps maintain dependable equipment operation. Selection should follow the approved full model code.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
The worksheet lists 73.27 m³/h. Compare the operating point with system resistance and the official performance curve.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.
The worksheet lists 27 dB. Enclosure acoustics, system resistance, and distance can change the installed result.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.