The 24 VDC Sanyo Denki 9RA0924S40011 is a DC axial fan sized 92 × 92 × 25 mm for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. A listed input of 2.4 W is the notable efficiency-related parameter. Check equipment integration review power demand.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92*92*25 |
| Max.Air Flow(m³/h) | 98.77 |
| Max.Pressure(Pa) | 62.3 |
| Input Power(W) | 2.4 |
| Speed(rpm) | 3850 |
| Noise(db) | 35 |
SANYO DENKI positions 9RA0924S40011 as a DC axial fan for servers, storage systems and ICT equipment. It helps equipment designers manage local hot spots where natural convection is insufficient.
A listed maximum airflow of 98.77 m3/h and maximum pressure of 62.3 Pa give engineers a clear basis for matching the fan to enclosure resistance. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Qualify performance with the production guard. It supports stable operation across the intended load cycle. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9RA0924S40011 is suitable for server chassis and computing nodes. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 9RA0924S40011 supports thermal management in storage arrays and data appliances. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
For network and other ICT hardware, 9RA0924S40011 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.
The worksheet lists 62.3 Pa. Use the official curve to match it to system resistance.
Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.