For servers, UPS systems, and telecom equipment, 9RA1212P1K001 combines 12 VDC operation with a 120 × 120 × 38 mm DC axial fan design. Series focus: high airflow and pressure. Its listed airflow of 270 m³/h is the standout performance value. Check duty point matching thermal-duty record. Focus: duty point matching thermal-duty record.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 270 |
| Max.Pressure(Pa) | 170 |
| Input Power(W) | 11.5 |
| Speed(rpm) | 4700 |
| Noise(db) | 50 |
For servers, storage systems and ICT equipment, the SANYO DENKI 9RA1212P1K001 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.
Its 270 m3/h maximum airflow supports rapid air exchange, while 170 Pa pressure capability helps overcome resistance within the finished equipment. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Confirm inlet clearance around nearby cables. The result supports repeatable OEM assembly. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
SANYO DENKI 9RA1212P1K001 serves server chassis and computing nodes that operate with sustained internal heat. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
9RA1212P1K001 is suitable for storage arrays and data appliances. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
The San Ace 9RA1212P1K001 supports thermal management in network and other ICT hardware. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration.
Use rated voltage, 120 × 120 × 38 mm dimensions, 270 m³/h airflow, 4700 rpm, and 11.5 W input for preliminary comparison.
Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.
No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.
The worksheet lists 270 m³/h. Compare the operating point with system resistance and the official performance curve.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 12 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.