Sanyo Denki 9RA1224P4G0011 combines a 120 × 120 × 25 mm DC axial fan platform with a 24 VDC rating for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Its listed airflow of 221 m³/h is the standout performance value. Selection focus: airflow path balancing ventilation capacity.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120*120*25 |
| Max.Air Flow(m³/h) | 221 |
| Max.Pressure(Pa) | 119.6 |
| Input Power(W) | 6.72 |
| Speed(rpm) | 4500 |
| Noise(db) | 47 |
9RA1224P4G0011 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
The rated peak airflow of 221 m3/h combines with 119.6 Pa pressure capability to support useful flow after installation losses are considered. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Check exhaust separation from the intake zone. It helps maintenance teams plan compatible replacements. Confirm the final fan curve in the assembled equipment.
For server chassis and computing nodes, 9RA1224P4G0011 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
SANYO DENKI 9RA1224P4G0011 serves storage arrays and data appliances that operate with sustained internal heat. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It provides a practical cooling path for OEM integration.
9RA1224P4G0011 is suitable for network and other ICT hardware. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
Use rated voltage, 120 × 120 × 25 mm dimensions, 221 m³/h airflow, 4500 rpm, and 6.72 W input for preliminary comparison.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
The worksheet lists 221 m³/h. Compare the operating point with system resistance and the official performance curve.