Within servers, UPS systems, and telecom equipment, 9S0812M4011 provides a 80×80×25 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed input of 0.96 W is the notable efficiency-related parameter. Check procurement data comparison cooling specification.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 80×80×25 |
| Max.Air Flow(m³/h) | 49.8 |
| Max.Pressure(Pa) | 27.5 |
| Input Power(W) | 0.96 |
| Speed(rpm) | 2500 |
| Noise(db) | 22 |
9S0812M4011 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
With up to 49.8 m3/h airflow and 27.5 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Test component temperatures at peak load. The review links cooling performance to the approved BOM. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
The San Ace 9S0812M4011 supports thermal management in server chassis and computing nodes. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
For storage arrays and data appliances, 9S0812M4011 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
SANYO DENKI 9S0812M4011 serves network and other ICT hardware that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
The worksheet lists 27.5 Pa. Use the official curve to match it to system resistance.
It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.

Selected for Refrigeration Cooling, ebm-papst S4D450-AU01-01 is a 400 V AC axial fan, with a focus on a documented 205 W input rating. It gives engineers a clear comparison point. Its documented data supports integration planning.
Read More
Suited to Refrigeration Cooling, the ebm-papst S4D350-AP08-30 is a 230 V AC axial fan, whose supplied data highlights a documented 115 W input rating. The rating aids system-fit checks.
Read More
Selected for Refrigeration Cooling, ebm-papst S4D560-AM03-01 is a 400 V AC axial fan, noted for a listed airflow of 11,245 m³/h. This supports duty-point selection. Its documented data supports integration planning.
Read More
Specified for Refrigeration Cooling, the ebm-papst S4D500-AM03-02 is a 400 V AC axial fan, distinguished by a listed pressure capability of 140 Pa. It provides a practical sizing reference.
Read More
Applied in Refrigeration Cooling, ebm-papst S4D450-AO14-01 is a 400 V AC axial fan, offering a listed acoustic value of 56 dB. This assists electrical and mechanical review. Its documented data supports integration planning.
Read More
Suited to Refrigeration Cooling, ebm-papst S4D450-AU01-02 is a 400 V AC axial fan, distinguished by a listed acoustic value of 73 dB. The rating aids system-fit checks. Its documented data supports integration planning.
Read More