Get Quote
Home > Products > By type > Axial Fans > 9S0812M4011 | Sanyo Denki 12VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling

9S0812M4011 Sanyo Axial Fan

Brand :
Sanyo
Model:
9S0812M4011 | Sanyo Denki 12VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

Within servers, UPS systems, and telecom equipment, 9S0812M4011 provides a 80×80×25 mm, 12 VDC DC axial fan configuration. High airflow is highlighted together with a high-static-pressure design. A listed input of 0.96 W is the notable efficiency-related parameter. Check procurement data comparison cooling specification.

Datasheet:
9S0812M4011 | Sanyo Denki 12VDC 0.96W DC Axial Fan for UPS, server and telecom equipment cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)12
Size(mm)80×80×25
Max.Air Flow(m³/h)49.8
Max.Pressure(Pa)27.5
Input Power(W)0.96
Speed(rpm)2500
Noise(db)22

Product Features

High Airflow Design

9S0812M4011 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.

With up to 49.8 m3/h airflow and 27.5 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Test component temperatures at peak load. The review links cooling performance to the approved BOM. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

Application Industry

Frequently Asked Questions

What should procurement confirm for 9S0812M4011?

Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.

Does 9S0812M4011 have a pressure rating?

The worksheet lists 27.5 Pa. Use the official curve to match it to system resistance.

What equipment is 9S0812M4011 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.

Which application details matter most for 9S0812M4011?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What maintenance does 9S0812M4011 require?

Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.

What is the lead time for 9S0812M4011?

Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.

Message Form