For renewable-energy power electronics, 9WP0824S401 combines 24 VDC operation with a 80 × 80 × 25 mm DC axial fan design. No exact entry appears in the supplied feature table, so bearing, control, and protection details require datasheet confirmation. 48.1 Pa maximum pressure is the most distinctive duty-point parameter.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80*80*25 |
| Max.Air Flow(m³/h) | 72.08 |
| Max.Pressure(Pa) | 48.1 |
| Input Power(W) | 2.4 |
| Speed(rpm) | 3400 |
| Noise(db) | 34 |
9WP0824S401 brings San Ace DC axial fan cooling to energy storage, photovoltaic inverters and charging equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
The rated peak airflow of 72.08 m3/h combines with 48.1 Pa pressure capability to support useful flow after installation losses are considered. Procurement teams should match the entire part number to the approved specification. Thermal testing in a representative chassis confirms cooling margin before volume release.
Confirm the operating environment for the suffix. The outcome supports dependable long-term equipment service. Confirm the final fan curve in the assembled equipment.
For energy storage systems and PCS equipment, 9WP0824S401 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
SANYO DENKI 9WP0824S401 serves photovoltaic inverter equipment that operate with sustained internal heat. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
9WP0824S401 is suitable for electric-vehicle charging equipment. Air circulation around processors, power devices and control electronics limits heat concentration and supports stable operation. It supports reliable OEM equipment cooling. Selection should follow the approved full model code.
It is listed for renewable-energy power electronics. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.
Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
Inspect dust buildup, airflow blockage, abnormal noise, mounting security, and wiring condition; disconnect power before service.
Its 24 VDC rating and documented 48.1 pa maximum pressure is the most distinctive duty-point parameter. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.