Built for telecom cabinets, base stations, and network equipment, SUNON EEC0382B2-000U-AB9 uses a 120 × 120 × 38 mm DC blower arrangement at 24 VDC. Up to 197.1 m³/h is its most prominent listed performance figure. Treat the suffix definition as a primary input to noise-control planning. Confirm environmental protection for the ordered version.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120x120x38mm |
| Max.Air Flow(m³/h) | 197.1 |
| Max.Pressure(Pa) | 64.8 |
| Input Power(W) | 5.4 |
| Speed(rpm) | 2600 |
| Noise(db) | 44 |
For industrial equipment, SUNON EEC0382B2-000U-AB9 serves as a DC brushless axial fan. The fan supports temperature control in equipment that runs through sustained or repeated duty cycles.
The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. A smooth inlet and outlet transition reduces avoidable turbulence, helping preserve useful cooling capacity and manage installed sound.
The final EEC0382B2-000U-AB9 selection should consider connector reach as part of the installation layout. Finishing replacement-fit checks in equipment qualification helps reduce integration uncertainty and supports reliable equipment cooling. Verify mounting, connector and airflow direction against the replacement space.
Review its 120 × 120 × 38 mm size, 197.1 m³/h airflow, 64.8 Pa pressure, system resistance, and available mounting space.
Assess reliability from the exact bearing, temperature, protection, and life data. The supplied series note alone does not confirm every suffix-specific option.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Compare its listed 5.4 W input with the required airflow and run time. Total savings depend on the complete system duty point.
The worksheet lists 44 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.

SUNON EEC0251B2-0000-A99 combines a 120 × 120 × 25 mm DC axial fan platform with a 12 VDC rating for telecom cabinets, base stations, and network equipment. Its 2700 rpm rating defines a lower-speed operating point. Base noise-control planning on the stated installation footprint. Confirm environmental protection for the ordered version.
Read More
Designed for telecom cabinets, base stations, and network equipment, SUNON EEC0251B1-0000-A99 is a 12 VDC DC axial fan in a 120 × 120 × 25 mm frame. Up to 183.8 m³/h is its most prominent listed performance figure. During noise-control planning, compare the model's selection parameters. Confirm environmental protection for the ordered version.
Read More
Within telecom cabinets, base stations, and network equipment, SUNON EEC0382B-1000U-G99 serves as a 120 × 120 × 38 mm DC blower operating at 24 VDC. Up to 234.5 m³/h is its most prominent listed performance figure. The recorded rated dataset should guide noise-control planning. Confirm environmental protection for the ordered version.
Read More
SUNON EEC0381B2-000U-A99Y is a 12 VDC DC blower in a 120 × 120 × 38 mm format for telecom cabinets, base stations, and network equipment. Up to 197.1 m³/h is its most prominent listed performance figure. For noise-control planning, start with the supplied motor input. Confirm environmental protection for the ordered version.
Read More
The EEC0384B3-000U-A99 is SUNON's 48 VDC, 120 × 120 × 38 mm DC axial fan option for telecom cabinets, base stations, and network equipment. Its 2100 rpm rating defines a lower-speed operating point. Use the documented ventilation capacity when planning noise-control planning. Confirm environmental protection for the ordered version.
Read More
The 120 × 120 × 38 mm EEC0384B2-000U-A99 brings 48 VDC DC axial fan cooling to telecom cabinets, base stations, and network equipment. Up to 197.1 m³/h is its most prominent listed performance figure. Review its equipment fit during noise-control planning. Confirm environmental protection for the ordered version.
Read More