SUNON configures PF60252V2-10000-A99 as a 60 × 60 × 25 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. 124.5 Pa maximum pressure is the standout documented duty-point value. Base installation review on the stated pressure capability. Obtain the applicable curve before final duty-point approval.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 60x60x25mm |
| Max.Air Flow(m³/h) | 53.5 |
| Max.Pressure(Pa) | 124.5 |
| Input Power(W) | 2.52 |
| Speed(rpm) | 7000 |
| Noise(db) | 40.7 |
The SUNON PF60252V2-10000-A99 positions a DC brushless axial fan for server and data-center equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.
SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats.
A dependable PF60252V2-10000-A99 installation starts with a review of exhaust separation. Complete wiring verification during sourcing review to confirm compatibility, operating margin and the information needed for repeat orders. Separate discharge air from the intake path inside the finished enclosure. The final assembly should be tested under its expected thermal load.
SUNON PF60252V2-10000-A99 serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON PF60252V2-10000-A99 serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON PF60252V2-10000-A99 serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON PF60252V2-10000-A99 serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Stock and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The listed speed is 7000 rpm. Confirm frequency, control method, and duty point for the installed system.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.

For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
Configured for servers and data-center electronics, SUNON PF60251V2-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 25 mm frame. 124.5 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's model record. Match the exact part number before approving a substitute.
Read More
For compact cooling within servers and data-center electronics, the PF60251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 124.5 Pa maximum pressure is the standout documented duty-point value. Review its duty-point values during design qualification. Match the exact part number before approving a substitute.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
For ventilation needs in servers and data-center electronics, the PF60251VX-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Treat the application data as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute.
Read More