Sized for servers and data-center electronics, SUNON PF60381B1-000U-S99 is a 12 VDC DC axial fan in a 60 × 60 × 38 mm frame. 572.9 Pa maximum pressure is the standout documented duty-point value. For mounting verification, start with the supplied airflow profile. Validate mounting and wiring from the model drawing.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 60x60x38mm |
| Max.Air Flow(m³/h) | 103 |
| Max.Pressure(Pa) | 572.9 |
| Input Power(W) | 14.4 |
| Speed(rpm) | 13200 |
| Noise(db) | 61.2 |
The PF60381B1-000U-S99 from SUNON addresses cooling needs in industrial equipment. As a DC brushless axial fan, it creates a defined inlet-to-outlet route across the thermal load.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. The enclosure should direct air across the heat source because bypass flow can reduce cooling even when the fan runs normally.
For PF60381B1-000U-S99 integration, prioritize inlet clearance. Include replacement-fit checks in engineering approval, and confirm the full model interface during prototype approval. This supports reliable cooling and traceable purchasing. Keep the intake free from nearby walls or bundled wiring.
The worksheet lists 14.4 W input. Check supply capacity and operating conditions before commissioning.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.
Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
Its documented 12 VDC rating and 572.9 pa maximum pressure is the standout documented duty-point value. allow comparison with the required duty point without assuming unlisted options.

The PF70201V1-1Q01U-S99 is SUNON's 12 VDC, 70 × 70 × 20 mm DC blower option for servers and data-center electronics. Up to 73.1 m³/h is its most prominent listed performance figure. During design qualification, compare the model's power demand. Match the exact part number before approving a substitute.
Read More
Built around servers and data-center electronics, SUNON PF80251B3-1000U-S99 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. Up to 90.1 m³/h is its most prominent listed performance figure. Review its acoustic value during airflow-path design. Obtain the applicable curve before final duty-point approval.
Read More
A 80 × 80 × 25 mm frame and 24 VDC rating define PF80252B1-1000U-S99, a DC axial fan for servers and data-center electronics. Up to 102 m³/h is its most prominent listed performance figure. Treat the system interface as a primary input to acoustic assessment. Match the exact part number before approving a substitute.
Read More
For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute.
Read More