SUNON PF75302B2-1B000-A99 combines a 75 × 75 × 30 mm DC blower platform with a 24 VDC rating for servers and data-center electronics. Its 3000 rpm rating defines a lower-speed operating point. Use the documented motor input when planning installation review. Obtain the applicable curve before final duty-point approval.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 75x75x30mm |
| Max.Air Flow(m³/h) | 23.4 |
| Max.Pressure(Pa) | 107.1 |
| Input Power(W) | 1.92 |
| Speed(rpm) | 3000 |
| Noise(db) | 38.6 |
For server and data-center equipment, SUNON PF75302B2-1B000-A99 serves as a DC brushless blower. The fan supports temperature control in equipment that runs through sustained or repeated duty cycles.
The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. System resistance, grille geometry and cable clearance should be reviewed together to maintain predictable air delivery.
For PF75302B2-1B000-A99 integration, prioritize inlet clearance. Include maintenance planning in engineering approval, and confirm the full model interface during sourcing review. This supports reliable cooling and traceable purchasing. Define cleaning and inspection intervals around the actual duty cycle.
SUNON PF75302B2-1B000-A99 serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON PF75302B2-1B000-A99 serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON PF75302B2-1B000-A99 serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON PF75302B2-1B000-A99 serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
Review its 75 × 75 × 30 mm size, 23.4 m³/h airflow, 107.1 Pa pressure, system resistance, and available mounting space.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.
Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.
Its documented 24 VDC rating and its 3000 rpm rating defines a lower-speed operating point. allow comparison with the required duty point without assuming unlisted options.
The listed speed is 3000 rpm. Confirm frequency, control method, and duty point for the installed system.

For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
For ventilation needs in servers and data-center electronics, the PF60251VX-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Treat the application data as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute.
Read More
Configured for servers and data-center electronics, SUNON PF60251V2-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 25 mm frame. 124.5 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's model record. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF60251V1-10000-A99 serves as a 60 × 60 × 25 mm DC axial fan operating at 12 VDC. 139.5 Pa maximum pressure is the standout documented duty-point value. The recorded product configuration should guide design qualification. Match the exact part number before approving a substitute.
Read More