Equipment designers working with servers and data-center electronics can evaluate SUNON PF80251B1-000U-G99, a DC axial fan rated at 12 VDC and sized 80 × 80 × 25 mm. 102.1 Pa maximum pressure is the standout documented duty-point value. Review its performance curve during wiring review. Confirm environmental protection for the ordered version.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 80x80x25mm |
| Max.Air Flow(m³/h) | 101.9 |
| Max.Pressure(Pa) | 102.1 |
| Input Power(W) | 4.1 |
| Speed(rpm) | 4800 |
| Noise(db) | 47.5 |
SUNON PF80251B1-000U-G99 is a DC brushless axial fan for industrial equipment. It establishes forced airflow where passive cooling cannot adequately protect heat-producing assemblies.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
A dependable PF80251B1-000U-G99 installation starts with a review of exhaust separation. Complete airflow mapping before ordering to confirm compatibility, operating margin and the information needed for repeat orders. Separate discharge air from the intake path inside the finished enclosure.
Review its 80 × 80 × 25 mm size, 101.9 m³/h airflow, 102.1 Pa pressure, system resistance, and available mounting space.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Its documented 12 VDC rating and 102.1 pa maximum pressure is the standout documented duty-point value. allow comparison with the required duty point without assuming unlisted options.

For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute.
Read More
For compact cooling within servers and data-center electronics, the PF60251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 124.5 Pa maximum pressure is the standout documented duty-point value. Review its duty-point values during design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251B1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Treat the installation footprint as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF40561B1-10000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 657.6 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's rated dataset. Match the exact part number before approving a substitute.
Read More