Used in servers and data-center electronics, SUNON PF80252B1-1000U-G99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. 102.1 Pa maximum pressure is the standout documented duty-point value. During airflow-path design, compare the model's ventilation capacity. Obtain the applicable curve before final duty-point approval.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80x80x25mm |
| Max.Pressure(Pa) | 102.1 |
| Input Power(W) | 3.72 |
| Speed(rpm) | 4800 |
The SUNON PF80252B1-1000U-G99 positions a DC brushless axial fan for industrial equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.
The exact fan curve should be reviewed against filters, guards and enclosure resistance so the selected operating point meets the required cooling load. The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling.
To integrate PF80252B1-1000U-G99 effectively, review outlet geometry at equipment level and arrange environmental checks during prototype approval. Confirmed system compatibility supports stable cooling and repeatable procurement. Preserve a clear discharge region to avoid unnecessary downstream turbulence.
Compare its listed 3.72 W input with the required airflow and run time. Total savings depend on the complete system duty point.
The listed speed is 4800 rpm. Confirm frequency, control method, and duty point for the installed system.
The supplied row has no airflow value; obtain the current performance curve before selection.
The exact bearing option is not confirmed by the row-level data. Check the complete suffix in the current SUNON specification.
Review its 80 × 80 × 25 mm size, 102.1 Pa pressure, system resistance, and available mounting space.

For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute.
Read More
For compact cooling within servers and data-center electronics, the PF60251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 124.5 Pa maximum pressure is the standout documented duty-point value. Review its duty-point values during design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251B1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Treat the installation footprint as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF40561B1-10000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 657.6 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's rated dataset. Match the exact part number before approving a substitute.
Read More