Sized for servers and data-center electronics, SUNON PF80252V2-10000-A99 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. Up to 96.8 m³/h is its most prominent listed performance figure. Base operating-cost analysis on the stated airflow profile. Validate mounting and wiring from the model drawing.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80x80x25mm |
| Max.Air Flow(m³/h) | 96.8 |
| Max.Pressure(Pa) | 87.2 |
| Input Power(W) | 3.03 |
| Speed(rpm) | 4500 |
| Noise(db) | 43.1 |
The PF80252V2-10000-A99 from SUNON addresses cooling needs in server and data-center equipment. As a DC brushless axial fan, it creates a defined inlet-to-outlet route across the thermal load.
SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats. Acoustic performance depends on the enclosure and operating point; low-turbulence integration helps avoid additional airflow noise.
For PF80252V2-10000-A99 integration, prioritize inlet clearance. Include duty-point validation in engineering approval, and confirm the full model interface in equipment qualification. This supports reliable cooling and traceable purchasing. Keep the intake free from nearby walls or bundled wiring.
SUNON PF80252V2-10000-A99 serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON PF80252V2-10000-A99 serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON PF80252V2-10000-A99 serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON PF80252V2-10000-A99 serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
Stock and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The listed speed is 4500 rpm. Confirm frequency, control method, and duty point for the installed system.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.
Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.
The worksheet lists 3.03 W input. Check supply capacity and operating conditions before commissioning.

For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
Configured for servers and data-center electronics, SUNON PF60251V2-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 25 mm frame. 124.5 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's model record. Match the exact part number before approving a substitute.
Read More
For compact cooling within servers and data-center electronics, the PF60251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 124.5 Pa maximum pressure is the standout documented duty-point value. Review its duty-point values during design qualification. Match the exact part number before approving a substitute.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
For ventilation needs in servers and data-center electronics, the PF60251VX-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Treat the application data as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute.
Read More