SUNON PF80252V3-10000-A99 combines a 80 × 80 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. Up to 90 m³/h is its most prominent listed performance figure. Treat the speed benchmark as a primary input to operating-cost analysis. Validate mounting and wiring from the model drawing.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80x80x25mm |
| Max.Air Flow(m³/h) | 90 |
| Max.Pressure(Pa) | 74.7 |
| Input Power(W) | 2.64 |
| Speed(rpm) | 4200 |
| Noise(db) | 41.5 |
SUNON PF80252V3-10000-A99 supports server and data-center equipment with DC brushless axial fan airflow. It is intended for installations where predictable air exchange is central to equipment stability.
SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats.
OEM teams specifying PF80252V3-10000-A99 should check airflow direction and complete duty-point validation in equipment qualification. A documented interface review helps purchasing teams control fit, cooling continuity and replacement planning. Record the intended operating point on the system resistance curve. The final assembly should be tested under its expected thermal load.
SUNON PF80252V3-10000-A99 serves server platforms. Airflow around processors, memory and power components helps address sustained computing loads. The fan gives OEM equipment a defined air route and supports stable server operation. It supports reliable equipment cooling.
SUNON PF80252V3-10000-A99 serves storage equipment. Airflow around drives, controllers and power assemblies helps address continuous data workloads. The fan gives OEM equipment a defined air route and supports reliable storage availability. It supports reliable equipment cooling.
SUNON PF80252V3-10000-A99 serves edge-computing systems. Airflow around compact processing and communication modules helps address high heat density. The fan gives OEM equipment a defined air route and supports consistent thermal control. It supports reliable equipment cooling.
SUNON PF80252V3-10000-A99 serves data-center equipment. Airflow around critical computing assemblies helps address round-the-clock heat generation. The fan gives OEM equipment a defined air route and supports infrastructure availability. It supports reliable equipment cooling.
The listed rating is 24 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.
The worksheet lists up to 90 m³/h. Verify the operating point against system resistance.
Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.
Review its 80 × 80 × 25 mm size, 90 m³/h airflow, 74.7 Pa pressure, system resistance, and available mounting space.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.

SUNON PF60251V3-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated technical profile. Match the exact part number before approving a substitute.
Read More
The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute.
Read More
For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
For ventilation needs in servers and data-center electronics, the PF60251VX-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 8300 rpm is the model's most distinctive operating parameter. Treat the application data as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
Configured for servers and data-center electronics, SUNON PF60251V2-10000-A99 is a 12 VDC DC axial fan in a 60 × 60 × 25 mm frame. 124.5 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's model record. Match the exact part number before approving a substitute.
Read More