Used in servers and data-center electronics, SUNON PF80381B2-Q050-S99 is a 12 VDC DC axial fan in a 80 × 80 × 38 mm frame. 184.3 Pa maximum pressure is the standout documented duty-point value. Use the documented operating point when planning design qualification. Match the exact part number before approving a substitute.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 80x80x38mm |
| Max.Air Flow(m³/h) | 142.9 |
| Max.Pressure(Pa) | 184.3 |
| Input Power(W) | 10.44 |
| Speed(rpm) | 6400 |
| Noise(db) | 54.5 |
The SUNON PF80381B2-Q050-S99 positions a DC brushless axial fan for industrial equipment. Its airflow path supports heat removal from enclosed components and toward the equipment exhaust.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. Correct airflow direction and inlet clearance help translate the documented operating point into reliable equipment-level cooling.
For an orderly design-in process, assess vibration transfer around PF80381B2-Q050-S99 and perform environmental checks during sourcing review. The result is a clearer cooling specification for engineering, purchasing and maintenance teams. Check how rotating forces couple into panels and sensitive assemblies.
Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.
The exact bearing option is not confirmed by the row-level data. Check the complete suffix in the current SUNON specification.
Use the listed voltage, size, 142.9 m³/h airflow, 6400 rpm, and 10.44 W input for preliminary comparison.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.
Confirm any missing bearing, connector, control, IP rating, life, certification, and performance-curve details for the complete part number.

For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute.
Read More
For compact cooling within servers and data-center electronics, the PF60251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 124.5 Pa maximum pressure is the standout documented duty-point value. Review its duty-point values during design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251B1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Treat the installation footprint as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF40561B1-10000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 657.6 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's rated dataset. Match the exact part number before approving a substitute.
Read More