Within servers and data-center electronics, SUNON PF92252B1-10000-G99 serves as a 92 × 92 × 25 mm DC axial fan operating at 24 VDC. Up to 127.4 m³/h is its most prominent listed performance figure. Review its pressure capability during design qualification. Match the exact part number before approving a substitute.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92x92x25mm |
| Max.Air Flow(m³/h) | 127.4 |
| Max.Pressure(Pa) | 87.2 |
| Input Power(W) | 4.92 |
| Speed(rpm) | 4500 |
| Noise(db) | 46.1 |
Designed for industrial equipment, the SUNON PF92252B1-10000-G99 provides DC brushless axial fan cooling in a format suited to equipment integration. It helps limit local heat buildup during operation.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market.
A dependable PF92252B1-10000-G99 installation starts with a review of exhaust separation. Complete environmental checks during sourcing review to confirm compatibility, operating margin and the information needed for repeat orders. Check that the selected variant suits the specified operating surroundings. The final assembly should be tested under its expected thermal load.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.
Speed-control capability is not stated for this complete part number. Confirm the signal and controller requirements before use.
Its documented 24 VDC rating and up to 127.4 m³/h is its most prominent listed performance figure. allow comparison with the required duty point without assuming unlisted options.
The listed rating is 24 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.
Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.

For servers and data-center electronics, PF60252B2-10000-A99 combines 24 VDC operation with a 60 × 60 × 25 mm DC axial fan design. 124.5 Pa maximum pressure is the standout documented duty-point value. Use the documented speed benchmark when planning installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60252B1-10000-A99 is SUNON's 24 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Review its airflow profile during installation review. Obtain the applicable curve before final duty-point approval.
Read More
The PF60251B3-10000-A99 is SUNON's 12 VDC, 60 × 60 × 25 mm DC axial fan option for servers and data-center electronics. 102.1 Pa maximum pressure is the standout documented duty-point value. Use the documented cooling specification when planning design qualification. Match the exact part number before approving a substitute.
Read More
For compact cooling within servers and data-center electronics, the PF60251B2-10000-A99 provides a 12 VDC DC axial fan configuration measuring 60 × 60 × 25 mm. 124.5 Pa maximum pressure is the standout documented duty-point value. Review its duty-point values during design qualification. Match the exact part number before approving a substitute.
Read More
SUNON PF60251B1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Treat the installation footprint as a primary input to design qualification. Match the exact part number before approving a substitute.
Read More
Within servers and data-center electronics, SUNON PF40561B1-10000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 657.6 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's rated dataset. Match the exact part number before approving a substitute.
Read More