Home > Products > By type > Axial Fans > PF92252V2-10000-A99 | SUNON 24V 3.48W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling

PF92252V2-10000-A99 SUNON Axial Fan

Brand :
SUNON
Model:
PF92252V2-10000-A99 | SUNON 24V 3.48W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

The PF92252V2-10000-A99 is SUNON's 24 VDC, 92 × 92 × 25 mm DC axial fan option for servers and data-center electronics. Up to 118.9 m³/h is its most prominent listed performance figure. Base operating-cost analysis on the stated ventilation capacity. Validate mounting and wiring from the model drawing.

Datasheet:
PF92252V2-10000-A99 | SUNON 24V 3.48W 92x92x25mm 118.9m3/h DC Axial Fan for Data Center Cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)24
Size(mm)92x92x25mm
Max.Air Flow(m³/h)118.9
Max.Pressure(Pa)74.7
Input Power(W)3.48
Speed(rpm)4200
Noise(db)43.7

Product Features

MagLev Cooling

For server and data-center equipment, SUNON PF92252V2-10000-A99 serves as a DC brushless axial fan. The fan supports temperature control in equipment that runs through sustained or repeated duty cycles.

SUNON's DC product line is developed around MagLev motor technology, supporting low-friction rotation, energy-conscious operation and long service life in compact formats.

To integrate PF92252V2-10000-A99 effectively, review outlet geometry at equipment level and arrange thermal-load testing in equipment qualification. Confirmed system compatibility supports stable cooling and repeatable procurement. Compare installed temperatures at representative equipment loads. The final assembly should be tested under its expected thermal load.

Application Industry

Frequently Asked Questions

How is PF92252V2-10000-A99 electrically connected?

The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.

Is PF92252V2-10000-A99 compatible with a replacement fan?

Match voltage, dimensions, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

Why choose PF92252V2-10000-A99 over a general cooling fan?

Its documented 24 VDC rating and up to 118.9 m³/h is its most prominent listed performance figure. allow comparison with the required duty point without assuming unlisted options.

What voltage is required by PF92252V2-10000-A99?

The listed rating is 24 VDC. Verify polarity or mains frequency, wiring, and protection before commissioning.

What airflow value is listed for PF92252V2-10000-A99?

The worksheet lists up to 118.9 m³/h. Verify the operating point against system resistance.

Does PF92252V2-10000-A99 have a documented pressure rating?

Yes. The worksheet lists up to 74.7 Pa; compare it with the system curve.