SUNON configures XG40561BX-1Q012-S9H as a 40 × 40 × 56 mm DC blower for servers and data-center electronics, operating at 12 VDC. 7.46 Pa maximum pressure is the standout documented duty-point value. Base application screening on the stated performance curve. Validate approvals and protection at complete-part-number level.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 40x40x56 |
| Max.Air Flow(m³/h) | 34.6 |
| Max.Pressure(Pa) | 7.46 |
| Input Power(W) | 27.6 |
| Speed(rpm) | 29700/25000 |
| Noise(db) | 72 |
The XG40561BX-1Q012-S9H from SUNON addresses cooling needs in industrial equipment. As a DC brushless axial fan, it creates a defined inlet-to-outlet route across the thermal load.
The SUNON product series carries RoHS compliance and recognized safety approvals; buyers should confirm the approval marks for this exact suffix and target market. The enclosure should direct air across the heat source because bypass flow can reduce cooling even when the fan runs normally.
A dependable XG40561BX-1Q012-S9H installation starts with a review of exhaust separation. Complete airflow mapping for service documentation to confirm compatibility, operating margin and the information needed for repeat orders. Separate discharge air from the intake path inside the finished enclosure.
The worksheet lists 72 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.
The supplied product-line reference discusses long-life cooling, but continuous-duty limits for this full suffix must be verified from its datasheet and operating conditions.
Keep the airflow path clear, secure the frame without distortion, and follow the exact wiring diagram and voltage rating.
Use the listed voltage, size, 34.6 m³/h airflow, 29700/25000 rpm, and 27.6 W input for preliminary comparison.
The workbook marks the product as RoHS compliant. Confirm UL, TUV, VDE, or other project-specific approvals for the exact suffix.

Configured for servers and data-center electronics, SUNON XG60561BX-1Q160-S9H is a 12 VDC DC blower in a 60 × 60 × 56 mm frame. The supplied data list 85.5 dB, an important acoustic selection parameter. During technical purchasing, compare the model's acoustic value. Request the exact performance curve for final engineering signoff.
Read More
Within servers and data-center electronics, SUNON XG60561BX-1Q017-S9H serves as a 60 × 60 × 56 mm DC blower operating at 12 VDC. The supplied data list 81.3 dB, an important acoustic selection parameter. The recorded electrical load should guide technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
For servers and data-center electronics, XG60561BX-1Q081-S9H combines 12 VDC operation with a 60 × 60 × 56 mm DC blower design. The supplied data list 76.6 dB, an important acoustic selection parameter. For technical purchasing, start with the supplied speed benchmark. Request the exact performance curve for final engineering signoff.
Read More
The XG60561BX-1Q011-S9H is SUNON's 12 VDC, 60 × 60 × 56 mm DC blower option for servers and data-center electronics. The supplied data list 78.3 dB, an important acoustic selection parameter. Use the documented airflow profile when planning technical purchasing. Request the exact performance curve for final engineering signoff.
Read More
SUNON XG40561BX-1Q962-S9H is a 12 VDC DC blower in a 40 × 40 × 56 mm format for servers and data-center electronics. The supplied data list 76.1 dB, an important acoustic selection parameter. During application screening, compare the model's motor input. Validate approvals and protection at complete-part-number level.
Read More
The 40 × 40 × 56 mm XG40561BX-1Q490-S9H brings 12 VDC DC blower cooling to servers and data-center electronics. 7.2 Pa maximum pressure is the standout documented duty-point value. For application screening, start with the supplied equipment fit. Validate approvals and protection at complete-part-number level.
Read More