GR40C-ZID.DC.CR 116240/H01 is a 3~380-480 VAC centrifugal fan for data centers, wind-power equipment. Its main supplied feature is a backward-curved impeller configuration. It also lists a 400 mm size specified in the upload data. Review electrical supply for installation planning. Check the exact variant before ordering.
| Rated Voltage(V) | 3~380-480 |
|---|---|
| Size(mm) | 400 |
| Input Power(W) | 2400 |
Designed for renewable-energy and power-conversion equipment, GR40C-ZID.DC.CR 116240/H01 combines ZIEHL-ABEGG engineering with a EC centrifugal fan format suited to OEM integration. The design supports stable thermal management in compact equipment layouts.
A free-running backward-curved impeller supports high static-pressure capability without a conventional scroll. The aerodynamic wheel and diffuser concept are designed for efficient airflow, stable rotation and favorable acoustic behavior.
Engineers integrating GR40C-ZID.DC.CR 116240/H01 should confirm the operating environment and final system curve. These checks align efficient heat removal with stable equipment performance and long-term service planning.
This duty requires consistent air movement because restricted passages and fluctuating loads can create local hot spots. In wind-power converters and turbine cooling systems, ZIEHL-ABEGG GR40C-ZID.DC.CR 116240/H01 removes heat from power electronics installed in wind-energy systems.
Used within HVAC, outdoor air-conditioning and ventilation equipment, GR40C-ZID.DC.CR 116240/H01 supports ventilation duty where filters, coils and duct resistance affect airflow. Regular air exchange helps the equipment handle long duty periods without trapping heat around key assemblies.
Reliable circulation is important here because compact assemblies leave limited space for passive heat dissipation. GR40C-ZID.DC.CR 116240/H01 supports data-center cooling and dry-cooler systems. In this duty, it supports heat rejection for data-center cooling and dry-cooler equipment.
No noise value is supplied for this model. Request exact acoustic data if the project has a sound limit.
The matched source highlights a backward-curved impeller configuration. Compare that point together with the listed electrical and dimensional data.
The supplied row lists 2400 W input. Compare these values with the real system operating point, not only the free-air rating.
Compare the full model suffix, voltage, size, motor or controller type, mounting, airflow, pressure, power, speed, and protection; do not copy data from a similar model.
Available performance data includes 2400 W input. Obtain the full curve when system resistance or part-load behavior matters.
The matched series documentation highlights efficiency-related design. Calculate savings from the actual operating point, control strategy, service interval, and purchase cost.

GR50C-ZID.GL.CR 116845/H01 is a 3~380-480 VAC centrifugal fan for data centers, wind-power equipment. Its main supplied feature is a 500 mm size specified in the upload data. It also lists 11043 m³/h maximum airflow stated for this model. Review housing geometry for procurement comparison.
Read More
GR50C-ZID.GG.CR 116844/H01 is a 3~380-480 VAC centrifugal fan for data centers, wind-power equipment. Its main supplied feature is ECblue motor and integrated-control technology referenced for this model. It also lists a 500 mm size specified in the upload data. Review controller compatibility for procurement comparison.
Read More
GR31C-ZID.DC.CR 116228/H01 is a 3~380-480 VAC centrifugal fan for data centers, wind-power equipment. Its main supplied feature is a 315 mm size specified in the upload data. It also lists 2500 W input power for the listed electrical version. Review procurement specification for system integration.
Read More
GR31C-ZID.DG.CR 116585/H01 is a 3~380-480 VAC centrifugal fan for data centers, wind-power equipment. Its main supplied feature is a backward-curved impeller configuration. It also lists a 315 mm size specified in the upload data. Review controller compatibility for system integration.
Read MoreGR35C-ZID.DC.CR 116234/H01 is a 3~380-480 VAC centrifugal fan for data centers, wind-power equipment. Its main supplied feature is 1550 Pa maximum pressure stated for this model. It also lists a 350 mm size specified in the upload data. Review equipment interface for system integration.
Read More
GR35C-ZID.DG.CR 116621/H01 is a 3~380-480 VAC centrifugal fan for data centers, wind-power equipment. Its main supplied feature is ECblue motor and integrated-control technology referenced for this model. It also lists a 355 mm size specified in the upload data. Review ventilation duty for system integration.
Read More