ZN050-ZIL.DC.V7P2 163482 is a 3~380-480 VAC axial fan for data centers, chillers, cold-chain equipment. Its main supplied feature is a 800 mm size specified in the upload data. It also lists a 7-blade impeller identified for this model. Review pressure requirement for ductwork design.
| Rated Voltage(V) | 3~ 380-480 |
|---|---|
| Size(mm) | 800 |
| Input Power(W) | 920 |
| Speed(rpm) | 1550 |
The ZIEHL-ABEGG ZN050-ZIL.DC.V7P2 163482 is a EC axial fan developed for industrial machinery and electrical equipment. It gives equipment designers a defined airflow or control solution for managing heat under continuous operating conditions.
Biomimetic impeller geometry inspired by owl-wing aerodynamics is optimized for high efficiency and low noise. Dynamic balancing and a compact air path support low vibration, energy-conscious operation and long service life.
Before volume ordering ZN050-ZIL.DC.V7P2 163482, confirm the duty point in the finished enclosure and review connector or controller requirements. The result is a documented solution for engineering, procurement and maintenance. Confirm the selected control function and protection class for the complete model.
In power transformers and electrical conversion equipment, ZIEHL-ABEGG ZN050-ZIL.DC.V7P2 163482 drives cooling air across transformer surfaces and associated electrical parts. Keeping the full suffix in technical records helps avoid mismatched replacements during maintenance.
Continuous heat removal helps prevent temperature rise from disrupting the surrounding process or electrical system. ZN050-ZIL.DC.V7P2 163482 supports wind-power converters and turbine cooling systems. In this duty, it removes heat from power electronics installed in wind-energy systems.
For chillers and heat-pump systems, the ZN050-ZIL.DC.V7P2 163482 EC axial fan keeps cooling air moving across coils when the unit operates for extended periods. Directed airflow is valuable when filters, coils or enclosure geometry add resistance to the cooling route.
For purchasing teams, the exact model reference supports controlled sourcing and service identification. Cold-chain, refrigerated display and storage equipment use ZN050-ZIL.DC.V7P2 163482 where the EC axial fan circulates air through refrigerated display, storage and cold-chain equipment.
The supplied application data covers data centers, chillers, cold-chain equipment. Confirm the installation's airflow, pressure, space, and electrical requirements.
The matched series documentation highlights efficiency-related design. Calculate savings from the actual operating point, control strategy, service interval, and purchase cost.
The product is classified as a axial fan. Use the full model code because nearby variants can differ in motor, mounting, and controls.
No exact IP protection level is stated for this item in the supplied sources. Confirm it before use in dusty, wet, or harsh locations.
The matched series information describes speed-control capability. Confirm the exact control method and required controller for this model before commissioning.
The matched source highlights a 800 mm size specified in the upload data. Compare that point together with the listed electrical and dimensional data.

Selected for data centers, chillers, cold-chain equipment, ZN050-ZIL.DG.V7P2 183180 uses a axial fan arrangement with 3~380-480 VAC. Its representative supplied feature is a 500 mm size specified in the upload data. Selection focus: controller compatibility during final model confirmation.
Read More
ZN050-ZIL.DC.V7P2 182597 is a 3~380-480 VAC axial fan for data centers, chillers, cold-chain equipment. Its main supplied feature is a 500 mm size specified in the upload data. It also lists a 7-blade impeller identified for this model. Review motor interface for system integration. Check the exact variant before ordering.
Read More
ZN050-ZIL.DC.V7P2 182475 is a 1~220-277 VAC axial fan for data centers, chillers, cold-chain equipment. Its main supplied feature is ECblue motor and integrated-control technology referenced for this model. It also lists a 7-blade impeller identified for this model. Review pressure requirement for system integration.
Read More
ZN091-ZIQ.GL.V5P1 180696 is a 3~380-480 VAC axial fan for data centers, chillers, cold-chain equipment. Its main supplied feature is 325 Pa maximum pressure stated for this model. It also lists a 910 mm size specified in the upload data. Review system resistance for final model confirmation.
Read More
ZN050-4DQ.4I.V7P1 180180 is a 400 VAC axial fan for data centers, chillers, cold-chain equipment. Its main supplied feature is ECblue motor and integrated-control technology referenced for this model. It also lists a 500 mm size specified in the upload data. Review airflow path for final model confirmation.
Read More
ZN091-ZIL.GL.V5P1 190373 is a 3~380-480 VAC axial fan for data centers, chillers, cold-chain equipment. Its main supplied feature is a 910 mm size specified in the upload data. It also lists 3200 W input power for the listed electrical version. Review maintenance access for application engineering.
Read More