Powerful centrifugal airflow systems for compact industrial cooling and ventilation applications.
| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() K3G450-PA31-03 | ebm-papst 3~380-480V 4450W EC Centrifugal Fan for Air Handling Applied in Air Handling, ebm-papst K3G450-PA31-03 is a 380-480V EC backward-curved centrifugal fan, featuring a documented 4,450 W input rating. This supports duty-point selection. |
3`380-480 | 450 | - | - | 4450 | 2480 | - | |
![]() K3G250-PR17-19 | ebm-papst 3~380-480V EC Centrifugal Fan for Air Handling Used in Air Handling, the ebm-papst K3G250-PR17-19 is a 380-480V EC backward-curved centrifugal fan, with a focus on 250 mm dimensions for installation planning. It gives engineers a clear comparison point. |
3`380-480 | 250 | - | - | - | - | - | |
![]() K3G355-PV70-01 | ebm-papst 3~380-480V 2900W EC Centrifugal Fan for Energy Storage Selected for Energy Storage, the ebm-papst K3G355-PV70-01 is a 380-480V EC backward-curved centrifugal fan, offering a listed pressure capability of 1,700 Pa. This enables specification-led selection. |
3`380-480 | 355 | 7955 | 1700 | 2900 | 3230 | 76 | |
![]() K3GA00-PV03-35 | ebm-papst 3~380-480V EC Centrifugal Fan for Dry Coolers Configured for Dry Coolers, the ebm-papst K3GA00-PV03-35 is a 380-480V EC backward-curved centrifugal fan, with 1,000 mm dimensions for installation planning. The rating clarifies its operating profile. |
3`380-480 | 1000 | - | - | - | - | - | |
![]() K3G800-PW07-35 | ebm-papst 3~380-480V EC Centrifugal Fan for Dry Coolers Intended for Dry Coolers, the ebm-papst K3G800-PW07-35 is a 380-480V EC backward-curved centrifugal fan, defined by 800 mm dimensions for installation planning. The data helps compare K-series variants. |
3`380-480 | 800 | - | - | - | - | - | |
![]() K3GA00-PV03-01 | ebm-papst 3~380-480V EC Centrifugal Fan for Data Center Cooling Built for Data Center Cooling, the ebm-papst K3GA00-PV03-01 is a 380-480V EC backward-curved centrifugal fan, documented with 1,000 mm dimensions for installation planning. This supports duty-point selection. |
3`380-480 | 1000 | - | - | - | - | - | |
![]() K3G800-PW07-01 | ebm-papst 3~380-480V 11300W EC Centrifugal Fan for Data Center Cooling Selected for Data Center Cooling, the ebm-papst K3G800-PW07-01 is a 380-480V EC backward-curved centrifugal fan, offering a listed airflow of 42,670 m³/h. This enables specification-led selection. |
3`380-480 | 800 | 42670 | 1450 | 11300 | 1370 | 78 | |
![]() K3G710-PW06-01 | ebm-papst 3~380-480V 11450W EC Centrifugal Fan for Data Center Cooling Suited to Data Center Cooling, the ebm-papst K3G710-PW06-01 is a 380-480V EC backward-curved centrifugal fan, distinguished by a listed airflow of 35,070 m³/h. The rating clarifies its operating profile. |
3`380-480 | 710 | 35070 | 1700 | 11450 | 1680 | 78 | |
![]() K3G630-PW04-01 | ebm-papst 3~380-480V 9780W EC Centrifugal Fan for Data Center Cooling Selected for Data Center Cooling, the ebm-papst K3G630-PW04-01 is a 380-480V EC backward-curved centrifugal fan, noted for a listed pressure capability of 1,500 Pa. It supports replacement and design review. |
3`380-480 | 630 | 15035 | 1500 | 9780 | 1950 | 81 | |
![]() K3G560-PC10-L1 | ebm-papst 3~380-480V 5950W EC Centrifugal Fan for Data Center Cooling Specified for Data Center Cooling, the ebm-papst K3G560-PC10-L1 is a 380-480V EC backward-curved centrifugal fan, with a listed airflow of 21,025 m³/h. The rating aids system-fit checks. |
3`380-480 | 560 | 21025 | 1400 | 5950 | 1860 | 79 | |
![]() K3G500-PC16-L1 | ebm-papst 3~380-480V 7000W EC Centrifugal Fan for Data Center Cooling Built for Data Center Cooling, the ebm-papst K3G500-PC16-L1 is a 380-480V EC backward-curved centrifugal fan, whose supplied data highlights a listed pressure capability of 1,800 Pa. The rating aids system-fit checks. |
3`380-480 | 500 | 19450 | 1800 | 7000 | 2400 | 84 | |
![]() K3G450-PB29-L1 | ebm-papst 3~380-480V 6800W EC Centrifugal Fan for Data Center Cooling Built for Data Center Cooling, the ebm-papst K3G450-PB29-L1 is a 380-480V EC backward-curved centrifugal fan, with a focus on a listed pressure capability of 2,100 Pa. It gives engineers a clear comparison point. |
3`380-480 | 450 | 16500 | 2100 | 6800 | 2800 | 82 | |
![]() K3G560-PB31-W5 | ebm-papst 3~380-480V 6800W EC Centrifugal Fan for Data Center Cooling Configured for Data Center Cooling, the ebm-papst K3G560-PB31-W5 is a 380-480V EC backward-curved centrifugal fan, identified by a listed pressure capability of 2,100 Pa. This enables specification-led selection. |
3`380-480 | 560 | 16500 | 2100 | 6800 | 2800 | 82 | |
![]() K3G500-PB24-W5 | ebm-papst 3~380-480V 3900W EC Centrifugal Fan for Data Center Cooling Aimed at Data Center Cooling, the ebm-papst K3G500-PB24-W5 is a 380-480V EC backward-curved centrifugal fan, distinguished by a listed airflow of 15,810 m³/h. The rating clarifies its operating profile. |
3`380-480 | 500 | 15810 | 1300 | 3900 | 2000 | 79 | |
![]() K3G450-PA31-W5 | ebm-papst 3~380-480V EC Centrifugal Fan for Data Center Cooling Used in Data Center Cooling, the ebm-papst K3G450-PA31-W5 is a 380-480V EC backward-curved centrifugal fan, centered on 450 mm dimensions for installation planning. This helps guide installation planning. |
3`380-480 | 450 | - | - | - | - | - | |
![]() K3G400-PA27-W5 | ebm-papst 3~380-480V 3650W EC Centrifugal Fan for Data Center Cooling Applied in Data Center Cooling, the ebm-papst K3G400-PA27-W5 is a 380-480V EC backward-curved centrifugal fan, defined by a documented speed of 2,800 rpm. The data helps compare K-series variants. |
3`380-480 | 400 | - | - | 3650 | 2800 | - | |
![]() K3G630-FB28-C1 | ebm-papst 3~380-480V 2950W EC Centrifugal Fan for Data Center Cooling Suited to Data Center Cooling, the ebm-papst K3G630-FB28-C1 is a 380-480V EC backward-curved centrifugal fan, offering a listed airflow of 21,035 m³/h. It gives engineers a clear comparison point. |
3`380-480 | 630 | 21035 | 700 | 2950 | 1300 | 69 | |
![]() K3G560-PB22-C1 | ebm-papst 3~380-480V 3060W EC Centrifugal Fan for Data Center Cooling Used in Data Center Cooling, the ebm-papst K3G560-PB22-C1 is a 380-480V EC backward-curved centrifugal fan, offering a listed airflow of 16,800 m³/h. It gives engineers a clear comparison point. |
3`380-480 | 560 | 16800 | 930 | 3060 | 1470 | 72 | |
![]() K3G500-PA26-C1 | ebm-papst 3~380-480V 3100W EC Centrifugal Fan for Data Center Cooling Built for Data Center Cooling, the ebm-papst K3G500-PA26-C1 is a 380-480V EC backward-curved centrifugal fan, whose supplied data highlights 500 mm dimensions for installation planning. It provides a practical sizing reference. |
3`380-480 | 500 | 14400 | 1125 | 3100 | 1810 | 74 | |
![]() K3G560-FA28-03 | ebm-papst 3~380-480V 3950W EC Centrifugal Fan for Data Center Cooling Used in Data Center Cooling, the ebm-papst K3G560-FA28-03 is a 380-480V EC backward-curved centrifugal fan, featuring a listed airflow of 18,535 m³/h. It supports replacement and design review. |
3`380-480 | 560 | 18535 | 1050 | 3950 | 1900 | 72 |
Before comparing models of centrifugal Fans, write down the real operating requirements: required airflow, system static pressure, available installation space and the electrical supply on site. A selection that ignores any of these four factors usually ends in returned goods or on-site retrofits.
Voltage and control define the shortlist. Standard options include 12/24/48 V DC and 115/230 V AC; for applications where operating points move, EC fans with PWM or 0-10 V input give precise speed control, and a tach signal provides the feedback many safety systems require.
Environmental conditions eliminate unsuitable models faster than any catalog filter. Check the ambient temperature range, required IP protection for dust and moisture, and the expected service life — ball-bearing units hold their noise and airflow figures far longer than sleeve-bearing designs in vertical or high-temperature positions. If the equipment must ship into regulated markets, verify UL, CE and RoHS compliance at this stage, and set a realistic noise target in dBA so acoustic requirements do not surface after installation.
Close the selection by de-risking the order: verify stock levels, confirm production lead time, and request datasheets plus dimension drawings for the final candidates so the mounting holes and connectors are checked before purchase. Share your operating point with us and we will validate the fit 766 products in this category are ready for comparison.
Across our project record, centrifugal Fans are specified wherever equipment must stay cool and air must keep moving: data centers and server rooms, commercial refrigeration, air handling and ventilation systems, telecom and battery cabinets, industrial machinery, and power electronics in the new-energy sector. What these projects share is a simple truth — the fan is small in cost but decisive for uptime, so it deserves the same engineering attention as the equipment it protects.
In a recent retrofit project, a customer's cooling unit had to keep running while its worn fan was exchanged. We identified a current-series replacement with identical mounting dimensions and an equivalent airflow-pressure curve, confirmed the tach output compatibility, and the installation was finished within a single maintenance window.
A second frequent case is refrigeration service: a condenser or evaporator fan fails and the exact original model is on long lead time. Instead of waiting, we check bearing type, IP rating, blade diameter and speed, then offer an equivalent that restores capacity immediately — one of the most common ways our stock protects cold chain operations.
New builds and replacement projects on ebmpapst equipment follow the same path at our company: you send the required airflow, pressure and dimensions; we respond with a shortlist, performance curves and firm delivery dates.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.