1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
PF60251B1-10000-A99 | SUNON 12V 2.34W 60x60x25mm 61.2m3/h DC Axial Fan for Data Center Cooling

SUNON PF60251B1-10000-A99 combines a 60 × 60 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 139.5 Pa maximum pressure is the standout documented duty-point value. Treat the installation footprint as a primary input to design qualification. Match the exact part number before approving a substitute.

12 60x60x25mm 61.2 139.5 2.34 7500 41.7
PF40561BX-10000-A9H | SUNON 12V 16.68W 40x40x56mm 53.9m3/h DC Axial Fan for Data Center Cooling

Engineered for servers and data-center electronics, SUNON PF40561BX-10000-A9H is a 12 VDC DC axial fan in a 40 × 40 × 56 mm frame. 936.6 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated selection parameters. Match the exact part number before approving a substitute.

12 40x40x56mm 53.9 936.6 16.68 - 65.9
PF40561B1-10000-A9H | SUNON 12V 10.68W 40x40x56mm 45.7m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF40561B1-10000-A9H serves as a 40 × 40 × 56 mm DC axial fan operating at 12 VDC. 657.6 Pa maximum pressure is the standout documented duty-point value. During design qualification, compare the model's rated dataset. Match the exact part number before approving a substitute.

12 40x40x56mm 45.7 657.6 10.68 - 62.3
PF40281V1-0000-A99 | SUNON 12V 8.88W 40x40x28mm 42.3m3/h DC Axial Fan for Data Center Cooling

Equipment designers working with servers and data-center electronics can evaluate SUNON PF40281V1-0000-A99, a DC axial fan rated at 12 VDC and sized 40 × 40 × 28 mm. 17600 rpm is the model's most distinctive operating parameter. The recorded motor input should guide design qualification. Match the exact part number before approving a substitute.

12 40x40x28mm 42.3 485.7 8.88 17600 56
PF40281B4-10000-A9H | SUNON 12V 1.16W 40x40x28mm 21.7m3/h DC Axial Fan for Data Center Cooling

For thermal management in servers and data-center electronics, the PF40281B4-10000-A9H provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 9200 rpm is the model's most distinctive operating parameter. Use the documented equipment fit when planning design qualification. Match the exact part number before approving a substitute.

12 40x40x28mm 21.7 149.5 1.16 9200 39.9
PF40281B3-10000-A9H | SUNON 12V 1.74W 40x40x28mm 26.2m3/h DC Axial Fan for Data Center Cooling

SUNON PF40281B3-10000-A9H combines a 40 × 40 × 28 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 11000 rpm is the model's most distinctive operating parameter. Review its suffix definition during design qualification. Match the exact part number before approving a substitute.

12 40x40x28mm 26.2 194.3 1.74 11000 43.9
PF40281B2-10000-A9H | SUNON 12V 2.64W 40x40x28mm 30.6m3/h DC Axial Fan for Data Center Cooling

Sized for servers and data-center electronics, SUNON PF40281B2-10000-A9H is a 12 VDC DC axial fan in a 40 × 40 × 28 mm frame. 13000 rpm is the model's most distinctive operating parameter. Treat the catalog specification as a primary input to design qualification. Match the exact part number before approving a substitute.

12 40x40x28mm 30.6 288.9 2.64 13000 48.7
PF40281B1-10000-A9H | SUNON 12V 6.12W 40x40x28mm 42.3m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF40281B1-10000-A9H serves as a 40 × 40 × 28 mm DC axial fan operating at 12 VDC. 17600 rpm is the model's most distinctive operating parameter. Base design qualification on the stated thermal-duty record. Match the exact part number before approving a substitute.

12 40x40x28mm 42.3 510.6 6.12 17600 56
PF38281BX-10000-A9H | SUNON 12V 6.84W 38x38x28mm 39.1m3/h DC Axial Fan for Data Center Cooling

SUNON configures PF38281BX-10000-A9H as a 38 × 38 × 28 mm DC axial fan for servers and data-center electronics, operating at 12 VDC. 20000 rpm is the model's most distinctive operating parameter. During design qualification, compare the model's performance curve. Match the exact part number before approving a substitute.

12 38x38x28mm 39.1 562.9 6.84 20000 57
PF38281B4-10000-A9H | SUNON 12V 1.14W 38x38x28mm 19.2m3/h DC Axial Fan for Data Center Cooling

The PF38281B4-10000-A9H is SUNON's 12 VDC, 38 × 38 × 28 mm DC axial fan option for servers and data-center electronics. 10000 rpm is the model's most distinctive operating parameter. The recorded mounting size should guide design qualification. Match the exact part number before approving a substitute.

12 38x38x28mm 19.2 154.4 1.14 10000 40.8
PF38281B3-10000-A9H | SUNON 12V 2.16W 38x38x28mm 25.3m3/h DC Axial Fan for Data Center Cooling

For airflow duties across servers and data-center electronics, the PF38281B3-10000-A9H provides a 12 VDC DC axial fan configuration measuring 38 × 38 × 28 mm. 13000 rpm is the model's most distinctive operating parameter. For design qualification, start with the supplied supply requirement. Match the exact part number before approving a substitute.

12 38x38x28mm 25.3 256.6 2.16 13000 47.3
PF38281B2-10000-A9H | SUNON 12V 3.18W 38x38x28mm 28.7m3/h DC Axial Fan for Data Center Cooling

SUNON PF38281B2-10000-A9H combines a 38 × 38 × 28 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. 15000 rpm is the model's most distinctive operating parameter. Use the documented static-pressure entry when planning design qualification. Match the exact part number before approving a substitute.

12 38x38x28mm 28.7 323.8 3.18 15000 51
PF38281B1-10000-A9H | SUNON 12V 3.78W 38x38x28mm 30.8m3/h DC Axial Fan for Data Center Cooling

Designed for servers and data-center electronics, SUNON PF38281B1-10000-A9H is a 12 VDC DC axial fan in a 38 × 38 × 28 mm frame. 16000 rpm is the model's most distinctive operating parameter. Review its volume-flow figure during design qualification. Match the exact part number before approving a substitute.

12 38x38x28mm 30.8 383.6 3.78 16000 51.8
PF36281BX-0000-A99 | SUNON 12V 36x36x28mm 38.7m3/h 3000rpm DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF36281BX-0000-A99 serves as a 36 × 36 × 28 mm DC axial fan operating at 12 VDC. 635.2 Pa maximum pressure is the standout documented duty-point value. Treat the sound level as a primary input to design qualification. Match the exact part number before approving a substitute.

12 36x36x28mm 38.7 635.2 - 3000 61.9
PF36281B1-0000-A99 | SUNON 12V 36x36x28mm 30.8m3/h 8400rpm DC Axial Fan for Data Center Cooling

Specified at 12 VDC, PF36281B1-0000-A99 is a SUNON DC axial fan for servers and data-center electronics in 36 × 36 × 28 mm dimensions. 403.5 Pa maximum pressure is the standout documented duty-point value. Base design qualification on the stated rotational rating. Match the exact part number before approving a substitute.

12 36x36x28mm 30.8 403.5 - 8400 55.7
PF80252B2-10000-A99 | SUNON 24V 3.24W 80x80x25mm 96.8m3/h DC Axial Fan for Data Center Cooling

The PF80252B2-10000-A99 is SUNON's 24 VDC, 80 × 80 × 25 mm DC axial fan option for servers and data-center electronics. Up to 96.8 m³/h is its most prominent listed performance figure. Base design qualification on the stated acoustic value. Match the exact part number before approving a substitute.

24 80x80x25mm 96.8 87.2 3.24 4500 44
PF40281BX-D430-S99 | SUNON 12V 11.4W 40x40x28mm 53.2m3/h DC Axial Fan for Data Center Cooling

For compact cooling within servers and data-center electronics, the PF40281BX-D430-S99 provides a 12 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 22000 rpm is the model's most distinctive operating parameter. During design qualification, compare the model's electrical load. Match the exact part number before approving a substitute.

12 40x40x28mm 53.2 777.2 11.4 22000 62
PF40281B1-000U-G99 | SUNON 12V 6.12W 40x40x28mm 42.3m3/h DC Axial Fan for Data Center Cooling

Within servers and data-center electronics, SUNON PF40281B1-000U-G99 serves as a 40 × 40 × 28 mm DC axial fan operating at 12 VDC. 17600 rpm is the model's most distinctive operating parameter. Use the documented application data when planning spares assessment. Confirm control inputs against the complete ordering code.

12 40x40x28mm 42.3 510.6 6.12 17600 56
GF92382B1-10000-AEP | SUNON 24V 20.4W 92x92x38mm 246.9m3/h DC Axial Fan for Data Center Cooling

SUNON GF92382B1-10000-AEP combines a 92 × 92 × 38 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. Up to 246.9 m³/h is its most prominent listed performance figure. Base spares assessment on the stated motor input. Confirm control inputs against the complete ordering code.

24 92x92x38mm 246.9 298.9 20.4 7200 60.6
GF92382B1-10000-ADP | SUNON 24V 20.4W 92x92x38mm 246.9m3/h DC Axial Fan for Data Center Cooling

Built around servers and data-center electronics, SUNON GF92382B1-10000-ADP is a 24 VDC DC axial fan in a 92 × 92 × 38 mm frame. Up to 246.9 m³/h is its most prominent listed performance figure. During spares assessment, compare the model's ventilation capacity. Confirm control inputs against the complete ordering code.

24 92x92x38mm 246.9 298.9 20.4 7200 60.6
Showing
521-540
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 24 25 26 27 28 29 30 ... 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.