| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() GF80382B1-10000-AEP | SUNON 24V 20.64W 80x80x38mm 177.5m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON GF80382B1-10000-AEP serves as a 80 × 80 × 38 mm DC axial fan operating at 24 VDC. 281.5 Pa maximum pressure is the standout documented duty-point value. Review its product configuration during fan selection. Use current model documentation to validate protection choices. |
24 | 80x80x38mm | 177.5 | 281.5 | 20.64 | 8000 | 59.7 | |
![]() GF80382B1-10000-ADP | SUNON 24V 20.64W 80x80x38mm 177.5m3/h DC Axial Fan for Data Center Cooling A 80 × 80 × 38 mm frame and 24 VDC rating define GF80382B1-10000-ADP, a DC axial fan for servers and data-center electronics. 281.5 Pa maximum pressure is the standout documented duty-point value. Treat the system interface as a primary input to fan selection. Use current model documentation to validate protection choices. |
24 | 80x80x38mm | 177.5 | 281.5 | 20.64 | 8000 | 59.7 | |
![]() GF80321B3-0000-AE9 | SUNON 12V 2.28W 80x80x32mm 85.5m3/h DC Axial Fan for Data Center Cooling The GF80321B3-0000-AE9 is SUNON's 12 VDC, 80 × 80 × 32 mm DC axial fan option for servers and data-center electronics. Up to 85.5 m³/h is its most prominent listed performance figure. Base fan selection on the stated cooling specification. Use current model documentation to validate protection choices. |
12 | 80x80x32mm | 85.5 | 67.3 | 2.28 | 4100 | 41.1 | |
![]() GF80321B3-0000-AC9 | SUNON 12V 2.28W 80x80x32mm 85.5m3/h DC Axial Fan for Data Center Cooling For ventilation needs in servers and data-center electronics, the GF80321B3-0000-AC9 provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 32 mm. Up to 85.5 m³/h is its most prominent listed performance figure. During fan selection, compare the model's duty-point values. Use current model documentation to validate protection choices. |
12 | 80x80x32mm | 85.5 | 67.3 | 2.28 | 4100 | 41.1 | |
![]() GF80321B2-0000-AE9 | SUNON 12V 2.76W 80x80x32mm 95m3/h DC Axial Fan for Data Center Cooling SUNON GF80321B2-0000-AE9 combines a 80 × 80 × 32 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Up to 95 m³/h is its most prominent listed performance figure. The recorded installation footprint should guide fan selection. Use current model documentation to validate protection choices. |
12 | 80x80x32mm | 95 | 79.7 | 2.76 | 4500 | 43.1 | |
![]() GF80321B2-0000-AC9 | SUNON 12V 2.76W 80x80x32mm 95m3/h DC Axial Fan for Data Center Cooling Used in servers and data-center electronics, SUNON GF80321B2-0000-AC9 is a 12 VDC DC axial fan in a 80 × 80 × 32 mm frame. Up to 95 m³/h is its most prominent listed performance figure. For fan selection, start with the supplied selection parameters. Use current model documentation to validate protection choices. |
12 | 80x80x32mm | 95 | 79.7 | 2.76 | 4500 | 43.1 | |
![]() GF80321B1-0000-AE9 | SUNON 12V 3.72W 80x80x32mm 100.9m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON GF80321B1-0000-AE9 serves as a 80 × 80 × 32 mm DC axial fan operating at 12 VDC. Up to 100.9 m³/h is its most prominent listed performance figure. Use the documented rated dataset when planning fan selection. Use current model documentation to validate protection choices. |
12 | 80x80x32mm | 100.9 | 89.7 | 3.72 | 4800 | 45.2 | |
![]() GF80321B1-0000-AC9 | SUNON 12V 3.72W 80x80x32mm 100.9m3/h DC Axial Fan for Data Center Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON GF80321B1-0000-AC9, a DC axial fan rated at 12 VDC and sized 80 × 80 × 32 mm. Up to 100.9 m³/h is its most prominent listed performance figure. Review its motor input during fan selection. Use current model documentation to validate protection choices. |
12 | 80x80x32mm | 100.9 | 89.7 | 3.72 | 4800 | 45.2 | |
![]() GF80252B7-0000-AE9 | SUNON 24V 1.08W 80x80x25mm 56.1m3/h DC Axial Fan for Data Center Cooling The GF80252B7-0000-AE9 is SUNON's 24 VDC, 80 × 80 × 25 mm DC axial fan option for servers and data-center electronics. Its 2600 rpm rating defines a lower-speed operating point. Treat the ventilation capacity as a primary input to fan selection. Use current model documentation to validate protection choices. |
24 | 80x80x25mm | 56.1 | 27.4 | 1.08 | 2600 | 28 | |
![]() GF80252B7-0000-AC9 | SUNON 24V 1.08W 80x80x25mm 56.1m3/h DC Axial Fan for Data Center Cooling For compact cooling within servers and data-center electronics, the GF80252B7-0000-AC9 provides a 24 VDC DC axial fan configuration measuring 80 × 80 × 25 mm. Its 2600 rpm rating defines a lower-speed operating point. Base fan selection on the stated equipment fit. Use current model documentation to validate protection choices. |
24 | 80x80x25mm | 56.1 | 27.4 | 1.08 | 2600 | 28 | |
![]() GF80252B6-0000-AE9 | SUNON 24V 1.42W 80x80x25mm 62.9m3/h DC Axial Fan for Data Center Cooling SUNON GF80252B6-0000-AE9 combines a 80 × 80 × 25 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. Its 2900 rpm rating defines a lower-speed operating point. During fan selection, compare the model's suffix definition. Use current model documentation to validate protection choices. |
24 | 80x80x25mm | 62.9 | 37.4 | 1.42 | 2900 | 30 | |
![]() GF80252B6-0000-AC9 | SUNON 24V 1.42W 80x80x25mm 62.9m3/h DC Axial Fan for Data Center Cooling Applied in servers and data-center electronics, SUNON GF80252B6-0000-AC9 is a 24 VDC DC axial fan in a 80 × 80 × 25 mm frame. Its 2900 rpm rating defines a lower-speed operating point. The recorded catalog specification should guide fan selection. Use current model documentation to validate protection choices. |
24 | 80x80x25mm | 62.9 | 37.4 | 1.42 | 2900 | 30 | |
![]() GF80252B5-0000-AE9 | SUNON 24V 1.76W 80x80x25mm 69.7m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON GF80252B5-0000-AE9 serves as a 80 × 80 × 25 mm DC axial fan operating at 24 VDC. Its 3200 rpm rating defines a lower-speed operating point. For fan selection, start with the supplied thermal-duty record. Use current model documentation to validate protection choices. |
24 | 80x80x25mm | 69.7 | 44.8 | 1.76 | 3200 | 33 | |
![]() GF80252B5-0000-AC9 | SUNON 24V 1.76W 80x80x25mm 69.7m3/h DC Axial Fan for Data Center Cooling SUNON configures GF80252B5-0000-AC9 as a 80 × 80 × 25 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 3200 rpm rating defines a lower-speed operating point. Use the documented performance curve when planning fan selection. Use current model documentation to validate protection choices. |
24 | 80x80x25mm | 69.7 | 44.8 | 1.76 | 3200 | 33 | |
![]() GF80251B7-0000-AE9 | SUNON 12V 1.01W 80x80x25mm 56.1m3/h DC Axial Fan for Data Center Cooling The GF80251B7-0000-AE9 is SUNON's 12 VDC, 80 × 80 × 25 mm DC axial fan option for servers and data-center electronics. Its 2600 rpm rating defines a lower-speed operating point. Review its mounting size during fan selection. Use current model documentation to validate protection choices. |
12 | 80x80x25mm | 56.1 | 27.4 | 1.01 | 2600 | 28 | |
![]() GF80251B7-0000-AC9 | SUNON 12V 1.01W 80x80x25mm 56.1m3/h DC Axial Fan for Data Center Cooling For thermal management in servers and data-center electronics, the GF80251B7-0000-AC9 provides a 12 VDC DC axial fan configuration measuring 80 × 80 × 25 mm. Its 2600 rpm rating defines a lower-speed operating point. Treat the supply requirement as a primary input to fan selection. Use current model documentation to validate protection choices. |
12 | 80x80x25mm | 56.1 | 27.4 | 1.01 | 2600 | 28 | |
![]() GF80251B6-0000-AE9 | SUNON 12V 1.44W 80x80x25mm 62.9m3/h DC Axial Fan for Data Center Cooling SUNON GF80251B6-0000-AE9 combines a 80 × 80 × 25 mm DC axial fan platform with a 12 VDC rating for servers and data-center electronics. Its 2900 rpm rating defines a lower-speed operating point. Base fan selection on the stated static-pressure entry. Use current model documentation to validate protection choices. |
12 | 80x80x25mm | 62.9 | 37.4 | 1.44 | 2900 | 30 | |
![]() GF80251B6-0000-AC9 | SUNON 12V 1.44W 80x80x25mm 62.9m3/h DC Axial Fan for Data Center Cooling Positioned for servers and data-center electronics, SUNON GF80251B6-0000-AC9 is a 12 VDC DC axial fan in a 80 × 80 × 25 mm frame. Its 2900 rpm rating defines a lower-speed operating point. During fan selection, compare the model's volume-flow figure. Use current model documentation to validate protection choices. |
12 | 80x80x25mm | 62.9 | 37.4 | 1.44 | 2900 | 30 | |
![]() GF80251B5-0000-AE9 | SUNON 12V 1.74W 80x80x25mm 69.7m3/h DC Axial Fan for Data Center Cooling Within servers and data-center electronics, SUNON GF80251B5-0000-AE9 serves as a 80 × 80 × 25 mm DC axial fan operating at 12 VDC. Its 3200 rpm rating defines a lower-speed operating point. The recorded sound level should guide fan selection. Use current model documentation to validate protection choices. |
12 | 80x80x25mm | 69.7 | 44.8 | 1.74 | 3200 | 33 | |
![]() GF80251B5-0000-AC9 | SUNON 12V 1.74W 80x80x25mm 69.7m3/h DC Axial Fan for Data Center Cooling Equipment designers working with servers and data-center electronics can evaluate SUNON GF80251B5-0000-AC9, a DC axial fan rated at 12 VDC and sized 80 × 80 × 25 mm. Its 3200 rpm rating defines a lower-speed operating point. For fan selection, start with the supplied rotational rating. Use current model documentation to validate protection choices. |
12 | 80x80x25mm | 69.7 | 44.8 | 1.74 | 3200 | 33 |
The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.
The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.
Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.