1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
GTB023EUG10R-VE1 | Delta Electronics 230VAC 135W EC Centrifugal Fan for Server Cooling

For server cooling, GTB023EUG10R-VE1 combines nominal 230VAC EC centrifugal fan operation with 0-10V/PWM speed control. The PDF specifies 135 W at free air and 180 W at maximum load, clarifying its power profile.

230 φ225 x 99 1259.7 650.1 135 3000 72
GTB031FUC20R N1 | Delta Electronics 1~230VAC 530W EC Centrifugal Fan for Server Cooling

GTB031FUC20R N1 is a nominal 230VAC EC centrifugal fan for server cooling. RS485 control and voltage/current monitoring are documented in its PDF, alongside 3014 m3/h maximum airflow and a 2500 rpm speed.

1~230 310 3014 74 530 2500 74.5
GTW012FU804-U00 | Delta Electronics 220VAC 11W EC Axial Fan for Server and Precision Cooling

GTW012FU804-U00 brings EC axial operation to a 120 x 120 x 38 mm server-cooling format. With 220VAC listed in the supplied table, the fan is specified at 4200 rpm and 246.5 m3/h maximum airflow.

220 120*120*38 246.5 112.1 11 4200 54.9
GTW040FUC15E-M001 | Delta Electronics 230VAC 330W EC Axial Fan for Server and Precision Cooling

GTW040FUC15E-M001 combines EC axial fan cooling with a nominal 230VAC supply for server and precision equipment. Its listed 5350 m3/h maximum airflow and 1650 rpm speed define this model's ventilation profile.

230 φ528 x 154 5350 198 330 1650 72
GTW017EUB12 | Delta Electronics 1~200-240VAC 240W EC Axial Fan for Server and Precision Cooling

GTW017EUB12 is an EC axial fan for server and precision cooling with a specified 200-240VAC input. Its PDF documents 0-10V/PWM speed control and a fan-speed signal, alongside a 5800 rpm rating.

1~200-240 200 x 122 1177 844 240 5800 70.5
GTW080PUR22E | Delta Electronics 3~380-480VAC 2200W EC Axial Fan for Server and Precision Cooling

GTW080PUR22E offers EC axial fan airflow for server and precision cooling at nominal 400VAC. The PDF specifies 0-10V/PWM and RS485 control, with 25077 m3/h maximum airflow and a rated 1020 rpm speed.

3~380-480 788 25077 - 2200 1020 -
GTW063HBK21E-M001 | Delta Electronics 3~230/400VAC 670W EC Axial Fan for Server Cooling

GTW063HBK21E-M001 is listed as an EC axial fan for server cooling on three-phase 230/400VAC. Its supplied 805 x 805 x 225 mm dimensions and 1200 rpm speed define the mechanical and operating selection points.

3~ 230/400 805*805*225 13218 212 670 1200 76
FFB0924VHE | Delta Electronics 24VDC 6.72W Axial Fan for Server and Telecommunications Cooling

FFB0924VHE provides 24VDC axial fan cooling for servers and telecom equipment in a 92 x 92 x 38 mm format. A listed 3800 rpm speed accompanies 145.2 m3/h maximum airflow and a 6.72 W electrical input.

24 92×92×38.00 145.2 101 6.72 3800 47.5
AFB0812L | Delta Electronics 12VDC 1.08W Axial Fan for Server and Power Supply Cooling

The AFB0812L pairs a 1.08 W input rating with a 2700 rpm axial fan rotor for server and power-supply cooling. Powered by 12VDC, it occupies 80 x 80 x 25.4 mm and lists a maximum airflow of 53.4 m3/h.

12 80x80x25.4 53.4 32.17 1.08 2700 28
AFB0712MB-F00 | Delta Electronics 12VDC 1.68W Axial Fan for Server and Power Supply Cooling

AFB0712MB-F00 is a 12VDC axial fan for server and power-supply cooling with a 70 x 70 x 15 mm body. Its listed 3300 rpm speed and 1.68 W input distinguish the model from higher-speed 70 mm alternatives.

12 70×70×15.00 47.9 30.6 1.68 3300 31
AFB0912VH-R00 | Delta Electronics 12VDC 4.8W Axial Fan for Server and Power Supply Cooling

AFB0912VH-R00 provides a suffix-specific 12VDC axial fan cooling option for server chassis. Rated dimensions are 92 x 92 x 25 mm; the listed 4.8 W input is relevant when budgeting power for multiple enclosure fans.

12 92*92*25 115.26 75.2 4.8 3800 45
AFB1212VH | Delta Electronics 12VDC 4.8W Axial Fan for Server and Power Supply Cooling

AFB1212VH combines a 25 mm-deep, 120 mm axial fan frame with 12VDC operation for server and power-supply cooling. The model lists a 3100 rpm speed and 4.8 W input, offering a defined alternative to faster variants.

12 120*120*25 61 9 4.8 3100 44.5
AFB1212SH | Delta Electronics 12VDC 6.36W Axial Fan for Server and Power Supply Cooling

AFB1212SH uses a 3400 rpm axial fan rotor for server and power-supply ventilation on 12VDC. Its 120 x 120 x 25 mm body and listed 6.36 W input distinguish its electrical and mechanical fit within the range.

12 120*120*25 66.5 11 6.36 3400 46.5
FFB1424SHG | Delta Electronics 24VDC 36W Axial Fan for Server and Telecommunications Cooling

The FFB1424SHG offers a 139.7 x 139.7 x 50.8 mm axial fan assembly for server and telecom cooling. Rated for 24VDC, it lists 464 m3/h maximum airflow and 3600 rpm operation, with 36 W input power specified.

24 139.7×139.7×50.8 464 194.5 36 3600 61.7
FFB0824EHE-F00 | Delta Electronics 24VDC 12W Axial Fan for Server and Telecom Cooling

FFB0824EHE-F00 is a 24VDC axial fan for telecom and server enclosures with an 80 x 80 x 38 mm body. Its listed 202.31 Pa maximum static pressure and 5700 rpm speed define the specified airflow profile.

24 80x80x38 136.2 202.31 12 5700 52.5
FFB0812SH-F00 | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling

FFB0812SH-F00 is a 12VDC axial fan for telecom equipment requiring an 80 mm footprint. The 25.4 mm profile is shallower than the 38 mm EHE format, while this model lists a 4500 rpm speed and 6 W electrical load.

12 80x80x25.4 113.88 97.58 6 4500 48.6
AFB1224H | Delta Electronics 24VDC 3.36W Axial Fan for Server and Power Supply Cooling

At a listed 2500 rpm, AFB1224H offers a different speed point for server and power-supply ventilation. This 24VDC axial fan uses a 120 x 120 x 25 mm frame, with 3.36 W input and 140.539 m3/h maximum airflow.

24 120*120*25 140.539 - 3.36 2500 38.5
AFB1224EHE-C | Delta Electronics 24VDC 20.4W Axial Fan for Server and Power Supply Cooling

The 210.2 Pa maximum-pressure entry is a key reason to evaluate AFB1224EHE-C for power-supply ventilation. This 24VDC axial fan occupies a 120 x 120 x 38 mm space; final selection still depends on the duty point.

24 120*120*38 361.42 210.2 20.4 4600 58.5
AFB0624MB | Delta Electronics 24VDC 1.44W Axial Fan for Server and Power Supply Cooling

A 1.44 W input makes AFB0624MB a lower-input entry among the listed 24VDC axial fan fans. For server and power-supply ventilation, it provides a 60 x 60 x 15 mm format with a specified 4000 rpm rotor.

24 60x60x15 26.1 38.54 1.44 4000 32
AFB0612HH-A | Delta Electronics 12VDC 2.04W Axial Fan for Server and Power Supply Cooling

AFB0612HH-A combines a 5000 rpm rotor with a 12VDC axial fan motor for server and power-supply cooling. Its listed 2.04 W input and 74 Pa maximum static pressure accompany a 60 x 60 x 25.4 mm frame.

12 60×60×25.40 46.8 74 2.04 5000 40
Showing
641-660
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 30 31 32 33 34 35 36 ... 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.