Get Quote
Home > Products > By industry > Data Center Cooling

Data Center Cooling

By brand

By type

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

816 results

Applied Filters

Showing
681-700
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
AFB0412MB | Delta Electronics 12VDC 1.08W Axial Fan for Server and Power Supply Cooling

AFB0412MB is a 12VDC axial fan for power supplies and server electronics, specified at 6000 rpm. The 40 x 40 x 15 mm model lists a 1.08 W input, distinguishing it from faster 40 mm variants in the supplied set.

12 40*40*15 13.77 - 1.08 6000 24.5
FFB1212EH | Delta Electronics 12VDC 17.4W Axial Fan for Server and Telecommunications Cooling

A 120 x 120 x 25 mm body gives FFB1212EH a shallower axial format for server and telecom ventilation. This 12VDC fan has a listed 4000 rpm speed and 17.4 W input, with 256 m3/h maximum airflow specified.

12 120*120*25 256 12.5 17.4 4000 56.4
AFB0412VB-A | Delta Electronics 12VDC 2.52W Axial Fan for Server and Power Supply Cooling

AFB0412VB-A combines a 12000 rpm speed with a 40 x 40 x 15 mm axial fan package. Powered by 12VDC for server and power-supply cooling, it lists 154.9 Pa maximum static pressure and a 2.52 W input rating.

12 40*40*15 25.8 154.9 2.52 12000 46
FFB1224EH | Delta Electronics 24VDC 15.12W Axial Fan for Server and Telecommunications Cooling

The FFB1224EH is a 24VDC axial fan for server and telecom cooling with a 25.4 mm frame depth. Its 120 mm square body is listed at 4000 rpm, with 255.42 m3/h maximum airflow and 15.12 W input.

24 120x120x25.4 255.42 121.9 15.12 4000 56.4
AFB1224HH | Delta Electronics 24VDC 4.32W Axial Fan for Server and Power Supply Cooling

AFB1224HH lists 161.64 m3/h maximum airflow for server and power-supply cooling. This 24VDC axial fan runs at 2800 rpm in a 120 x 120 x 25.4 mm housing, with 4.32 W input distinguishing its operating point.

24 120x120x25.4 161.64 75.81 4.32 2800 41.5
AFB0512HD | Delta Electronics 12VDC Axial Fan for Server, Storage and Power Supply Cooling

AFB0512HD is a 12VDC axial fan intended for server, storage and power-supply ventilation. Its supplied 50 x 50 x 20 mm dimensions define an intermediate-depth format between 15 mm and 25 mm enclosure options.

12 50*50*20 - - - - -
FFB03812HHN | Delta Electronics 12VDC 10.2W Axial Fan for Server and Telecommunications Cooling

The FFB03812HHN is a 12VDC axial fan for server and telecommunications cooling. A 38 x 38 x 28 mm envelope is its key documented fit characteristic; confirm the HHN-specific performance before final selection.

12 38x38x28 38.6 846.9 10.2 23000 62.5
FFB0812SH | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling

FFB0812SH combines a 4500 rpm axial fan rotor with 12VDC operation for server and telecom enclosures. Its 80 x 80 x 25.4 mm dimensions are paired with a listed 97.58 Pa maximum static pressure and 6 W input.

12 80x80x25.4 113.88 97.58 6 4500 48.6
AFB0824HHB | Delta Electronics 24VDC 2.4W Axial Fan for Server and Power Supply Cooling

An 80 x 80 x 15 mm axial layout distinguishes AFB0824HHB for server and power-supply cooling. The 24VDC fan is listed at 3400 rpm and 2.4 W, with 60.6 m3/h maximum airflow for comparing enclosure options.

24 80*80*15 60.6 39.5 2.4 3400 37
FFB0412SHN | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling

A 6 W input and 13000 rpm speed define FFB0412SHN for server and telecom ventilation. Operating on 12VDC, this axial fan measures 40 x 40 x 28 mm and lists 40.8 m3/h maximum airflow in the supplied data.

12 40*40*28 40.8 - 6 13000 54.5
AFB1224EHE | Delta Electronics 24VDC 20.4W Axial Fan for Server and Power Supply Cooling

AFB1224EHE offers a 4600 rpm axial fan design for server and power-supply cooling on 24VDC. The supplied frame dimensions are 119 x 119 x 38 mm, with 361 m3/h maximum airflow and 20.4 W input listed.

24 119*119*38 361 - 20.4 4600 58.5
AFB0424VHD | Delta Electronics 24VDC 2.16W Axial Fan for Server and Power Supply Cooling

For server electronics, AFB0424VHD combines a 40 mm axial footprint with a 20 mm depth. This 24VDC fan lists 103.6 Pa maximum pressure and 9000 rpm operation, with 2.16 W input defining its electrical load.

24 40*40*20 17.17 103.6 2.16 9000 32.5
AFB0724VH | Delta Electronics 24VDC 6.48W Axial Fan for Server and Power Supply Cooling

The 70 mm AFB0724VH axial fan is listed for server cooling on 24VDC. A 25.4 mm body depth defines the required clearance, while its 6.48 W input distinguishes it from the supplied 12VDC version of similar speed.

24 70*70*25.4 88.4 107.9 6.48 5500 47.5
FFB0412EN | Delta Electronics 12VDC 17.4W Axial Fan for Server and Telecommunications Cooling

FFB0412EN is a 12VDC axial fan for server and telecom equipment with a listed 25000 rpm rotor. The 40 x 40 x 28 mm body houses this high-speed configuration, with 17.4 W input specified for supply planning.

12 40*40*28 - - 17.4 25000 64
AFB1224HHE | Delta Electronics 24VDC 6.48W Axial Fan for Server and Power Supply Cooling

A listed 3500 rpm speed and 6.48 W input identify AFB1224HHE for server and power-supply cooling. This 24VDC axial fan has a 120 x 120 x 38 mm frame, providing a specific fit for 38 mm-deep installations.

24 120*120*38 222 9 6.48 3500 47
AFB1212GHE | Delta Electronics 12VDC 29.4W Axial Fan for Server and Power Supply Cooling

AFB1212GHE is the 12VDC axial fan option with a listed 29.4 W input in this 120 mm server-cooling group. The 5200 rpm specification helps distinguish its operating point from the lower-speed SHE and HHE entries.

12 120*120*38 409.7 269.5 29.4 5200 62
AFB0612EH-AB | Delta Electronics 12VDC 4.56W Axial Fan for Server and Power Supply Cooling

AFB0612EH-AB is a 12VDC axial fan with a 60 x 60 x 25.4 mm envelope for server and power-supply ventilation. Its listed 65.28 m3/h maximum airflow and 135.5 Pa maximum pressure define its airflow profile.

12 60*60*25.4 65.28 135.5 4.56 6800 46.5
AFB1212HHE | Delta Electronics 12VDC 5.52W Axial Fan for Server and Power Supply Cooling

The 2900 rpm AFB1212HHE is a 12VDC axial fan intended for server ventilation. With 5.52 W listed input, it differs from the faster SHE and GHE entries; allow for its 120 mm square frame and 38 mm body depth.

12 120*120*38 204 88.3 5.52 2900 44
FFB03812VHN | Delta Electronics 12VDC 10.2W Axial Fan for Server and Telecommunications Cooling

FFB03812VHN puts a 23000 rpm axial fan assembly into a 38 x 38 x 28 mm space. Listed for server and telecom cooling on 12VDC, it has an 846.9 Pa maximum static-pressure specification and 10.2 W input.

12 38x38x28 38.6 846.9 10.2 23000 62.5
FFB0612EHE | Delta Electronics 12VDC 14.4W Axial Fan for Server and Telecommunications Cooling

FFB0612EHE is the 12VDC axial fan configuration with 14.4 W listed input in this 60 mm telecom-cooling group. The 38 mm-deep housing permits a specific mechanical fit; its nominal speed is recorded as 8000 rpm.

12 60×60×38 85.3 242.1 14.4 8000 54.5
Showing
681-700
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 32 33 34 35 36 37 38 39 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.