1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
GTM031PHJ22M | Delta Electronics 400VAC 1000W EC Centrifugal Fan for Server and Precision Cooling

At 3060 rpm, GTM031PHJ22M provides an EC centrifugal fan format for server and precision cooling. This 400VAC model lists 1035 Pa maximum pressure and 1000 W input, with maximum airflow specified as 3704 m3/h.

400 400 3704 1035 1000 3060 81
GTM045PUV36R-V001 | Delta Electronics 400VAC EC Centrifugal Fan for Server and Precision Cooling

The GTM045PUV36R-V001 is a 400VAC EC centrifugal fan for server and precision cooling. Its documented 450 mm size defines the mechanical selection point; suffix-specific control details need confirmation.

400 450 - - - - -
GTM063PBU41R | Delta Electronics 3~380-480VAC 4200W EC Centrifugal Fan for Server Cooling

GTM063PBU41R is an EC centrifugal fan listed for server cooling on three-phase 380-480VAC. The 630 mm format is specified at 1800 rpm, with 20592 m3/h maximum airflow and a 4200 W input rating.

3~ 380-480 630 20592 - 4200 1800 -
GTM036PUS32R | Delta Electronics 400VAC 3650W EC Centrifugal Fan for Server and Precision Cooling

With 2585 Pa listed maximum pressure, GTM036PUS32R is an EC centrifugal fan option for server and precision cooling. Its 400VAC drive is rated at 3650 rpm, in an assembly measuring 500 x 500 x 365 mm.

400 500 x 500 x 365 8602 2585 3650 3650 90
GTB050PUT33R E1 | Delta Electronics 400VAC 3100W EC Centrifugal Fan for Server Cooling

GTB050PUT33R E1 pairs a 500 mm centrifugal fan format with EC drive for server ventilation. The 400VAC model lists 12286 m3/h maximum airflow and 1145 Pa maximum pressure, with 3100 W input specified.

400 500 12286 1145 3100 - -
GTB036PCN25R-M E1 | Delta Electronics 3~200-240VAC 735W EC Centrifugal Fan for Server Cooling

GTB036PCN25R-M E1 is an EC centrifugal fan for server cooling, rated at three-phase 230/400VAC. Its PDF documents 0-10V, PWM and 4-20mA inputs plus RS485 Modbus, providing several control-interface choices.

3~ 200-240 φ360 x 251 5362 880 735 2250 81
GTB036PUD25E N1 | Delta Electronics 400VAC 1000W EC Centrifugal Fan for Server Cooling

GTB036PUD25E N1 is a 400VAC EC centrifugal fan for server cooling. A listed 919 Pa maximum pressure complements its 360 x 250 mm envelope and 2200 rpm rating, supporting comparison of ducted cooling designs.

400 ψ360 x 250 5573 919 1000 2200 81
GTB063PUU38R-VHR3 | Delta Electronics 3~380-480VAC 3700W EC Centrifugal Fan for Server Cooling

For server cooling, GTB063PUU38R-VHR3 offers an EC centrifugal fan format with a listed 630 mm size. The supplied input range is three-phase 380-480VAC, with 20381 m3/h maximum airflow and 1807 Pa maximum pressure.

3~380-480 630 20381 1807 3700 - -
GTW091PUU29E-V001 | Delta Electronics 400VAC 4000W EC Axial Fan for Server and Precision Cooling

GTW091PUU29E-V001 uses nominal 400VAC EC axial fan drive for server and precision cooling. The supplied PDF documents IP55 protection, 0-10V/PWM control and a maximum airflow of 34410 m3/h at the rated setup.

400 910 11906 364 4000 1260 86.3
FFB0824EHE-R00 | Delta Electronics 24VDC 12W Axial Fan for Server and Telecom Cooling

FFB0824EHE-R00 is a 24VDC axial fan intended for server and telecom ventilation. Its listed 202.3 Pa maximum static pressure is a key feature of the 80 x 80 x 38 mm assembly, rated at 5700 rpm.

24 80*80*38 136.2 202.3 12 5700 52.5
FFB0824SH-BRD | Delta Electronics 24VDC 5.76W Axial Fan for Server and Telecom Cooling

A listed 97.6 Pa maximum static pressure characterizes FFB0824SH-BRD for telecom and server enclosures. This 24VDC axial fan uses an 80 x 80 x 25 mm frame, with 4500 rpm operation and 5.76 W input.

24 80*80*25 113.9 97.6 5.76 4500 48.6
FFB1524UHG-ZSS | Delta Electronics 24VDC 115W Axial Fan for Server and Telecom Cooling

FFB1524UHG-ZSS serves server and telecom cooling with a 172 x 150 x 51 mm axial fan assembly. Specified for 24VDC, this suffix-specific model lists 569.5 m3/h maximum airflow and a rotor speed of 3400 rpm.

24 172*150*51 569.5 - 115 3400 -
AFB0824VH | Delta Electronics 24VDC 3.36W Axial Fan for Server and Power Supply Cooling

The AFB0824VH pairs a 3600 rpm rotor with a 24VDC axial fan motor for server and power-supply cooling. Its 80 x 80 x 25 mm body is rated at 3.36 W input, separating it from the faster SH model in the list.

24 80*80*25 72 - 3.36 3600 38
AFB0824SH | Delta Electronics 24VDC 3.84W Axial Fan for Server and Power Supply Cooling

AFB0824SH is an 80 x 80 x 25 mm axial fan for server and power-supply enclosures. Using 24VDC, it lists 4000 rpm operation and a 3.84 W input, with 79 m3/h maximum airflow specified for selection.

24 80*80*25 79 - 3.84 4000 40
BSB01503HA3-01 | Delta Electronics 3VDC 0.24W Centrifugal Blower for Electronic Equipment Cooling

BSB01503HA3-01 takes centrifugal cooling into a 15 x 15 x 3.5 mm package for miniature electronics. The 3VDC blower is listed at 20000 rpm, with a 0.24 W input suited to evaluating its supply requirement.

3 15x15x3.5 0.525 - 0.24 20000 33
AFB0624VHC | Delta Electronics 24VDC 2.88W Axial Fan for Server and Power Supply Cooling

AFB0624VHC delivers axial fan airflow from a 24VDC supply for server and power-supply cooling. A listed 47.1 m3/h maximum airflow distinguishes its 60 x 60 x 15 mm format, alongside a 5400 rpm speed rating.

24 60*60*15 47.1 62.9 2.88 5400 38
AFB0624HHB | Delta Electronics 24VDC 2.4W Axial Fan for Server and Power Supply Cooling

The AFB0624HHB combines a 60 mm square frame with a 15 mm profile for server and power-supply ventilation. This 24VDC axial fan is listed at 4500 rpm, with 2.4 W input and 48.7 Pa maximum static pressure.

24 60*60*15 29.4 48.7 2.4 4500 35
AFB0524HHB-F00 | Delta Electronics 24VDC 1.92W Axial Fan for Server and Power Supply Cooling

For a shallow 50 mm installation, AFB0524HHB-F00 is a 24VDC axial fan intended for server and power-supply cooling. Its 15 mm depth is paired with 6400 rpm operation and a listed 27.6 m3/h maximum airflow.

24 50*50*15 27.6 78.5 1.92 6400 36
ASB0312HA-D | Delta Electronics 12VDC 0.84W DC Fan for Electronic Equipment Cooling

ASB0312HA-D addresses electronic equipment cooling with a 30 x 30 x 10 mm brushless fan format. Powered by 12VDC, the compact assembly is listed at 10500 rpm and 0.84 W for space-limited integration.

12 30*30*10 7.3 53.3 0.84 10500 27
AFB0624VH-A | Delta Electronics 24VDC 3.36W Axial Fan for Server and Power Supply Cooling

A 3.36 W rating accompanies the 24VDC AFB0624VH-A axial fan for servers and power supplies. Its 60 x 60 x 25 mm body houses a 5500 rpm rotor, with a listed maximum airflow of 51.816 m3/h.

24 60*60*25 51.816 - 3.36 5500 42.5
Showing
721-740
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 32 33 34 35 36 37 38 39 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.