Home > Products > By industry > Data Center Cooling

Data Center Cooling

By brand

By type

Rated Voltage(V)

Size(mm)

Max.Air Flow(m³/h)

Max.Pressure(Pa)

Input Power(W)

Speed(rpm)

Noise(db)

Stocking Options

Environmental Options

Media

Exclude

816 results

Applied Filters

Showing
761-780
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
AFB0624EHW7F | Delta Electronics 24VDC 5.76W Axial Fan for Server and Power Supply Cooling

AFB0624EHW7F targets server and power-supply ventilation with a 24VDC axial fan design. A listed maximum static pressure of 135.5 Pa complements its 60 x 60 x 25 mm frame and 6800 rpm operating speed.

24 60*60*25 65.28 135.5 5.76 6800 46.5
AFB0712VH-A | Delta Electronics 12VDC 5.28W Axial Fan for Server and Power Supply Cooling

Powered by 12VDC, AFB0712VH-A uses a 70 x 70 x 25 mm axial fan layout for server and power-supply cooling. The model is specified at 5500 rpm, with 88.349 m3/h maximum airflow and a 5.28 W input rating.

12 70*70*25 88.349 - 5.28 5500 47.5
FFB0812EHE | Delta Electronics 12VDC 10.8W Axial Fan for Server and Telecommunications Cooling

For server airflow in an 80 mm frame, FFB0812EHE uses a 38 mm-deep axial design. The 12VDC fan has a 5700 rpm rating and a listed maximum airflow of 136 m3/h, with 10.8 W input power specified.

12 80*80*38 136 - 10.8 5700 52.5
FFB0924EHE | Delta Electronics 24VDC 12W Axial Fan for Server and Telecommunications Cooling

FFB0924EHE combines a 92 x 92 x 38 mm axial fan assembly with 24VDC operation for telecom and server cooling. Its listed 187 m3/h maximum airflow is paired with a 4800 rpm speed and 12 W input.

24 92*92*38 187 17 12 4800 55
AFB0712VHD | Delta Electronics 12VDC 4.2W Axial Fan for Server and Power Supply Cooling

The 20 mm depth of AFB0712VHD suits shallow server or power-supply enclosures. Running on 12VDC, this 70 mm axial fan is specified at 5000 rpm and 4.2 W, with 79.73 m3/h maximum airflow listed.

12 70*70*20 79.73 - 4.2 5000 35
AFB0924SH-A | Delta Electronics 24VDC 9.6W Axial Fan for Server and Power Supply Cooling

AFB0924SH-A is a 24VDC axial fan intended for server and power-supply ventilation. Its 92 x 92 x 25 mm housing accommodates a 4800 rpm rotor, while the specified 9.6 W input helps define supply sizing.

24 92*92*25 60.3 13.5 9.6 4800 53
AFB0724VH-A | Delta Electronics 24VDC 6.48W Axial Fan for Server and Power Supply Cooling

In the 70 mm class, AFB0724VH-A pairs a 25 mm frame depth with 5500 rpm operation. This 24VDC axial fan is listed for server and power-supply cooling, with a maximum airflow rating of 88.349 m3/h.

24 70*70*25 88.349 - 6.48 5500 47.5
FFB0424VHN | Delta Electronics 24VDC 2.4W Axial Fan for Server and Telecommunications Cooling

Server and telecom enclosures needing a 40 mm footprint can consider FFB0424VHN. This 24VDC axial fan uses a deeper 28 mm body and a 9500 rpm rotor; listed input power is 2.4 W for this configuration.

24 40*40*28 26.843 - 2.4 9500 45
AFB0524VHD | Delta Electronics 24VDC 2.4W Axial Fan for Server and Power Supply Cooling

A 75.51 Pa maximum static-pressure rating characterizes AFB0524VHD. Intended for server or power-supply cooling, the 24VDC axial fan uses a 50 x 50 x 20 mm body and is specified to run at 7000 rpm.

24 50x50x20 34.5 75.51 2.4 7000 40.5
AFB0424SHB | Delta Electronics 24VDC 2.88W Axial Fan for Server and Power Supply Cooling

AFB0424SHB fits a 40 x 40 x 15 mm space in servers or power supplies. Its 24VDC axial fan design is specified at 11000 rpm, making rotor speed the defining selection point within this small frame size.

24 40*40*15 25.211 - 2.88 11000 41.5
FFB0624EHE | Delta Electronics 24VDC 9.12W Axial Fan for Server and Telecommunications Cooling

FFB0624EHE brings a 38 mm-deep, 60 mm axial format to server and telecom cooling. The 24VDC model runs at 8000 rpm, with 85.34 m3/h maximum airflow specified for this higher-speed enclosure fan.

24 60*60*38 85.34 - 9.12 8000 54.5
AFB0624VHBWPE | Delta Electronics 24VDC 2.64W Axial Fan for Server and Power Supply Cooling

A 15 mm profile distinguishes AFB0624VHBWPE for server chassis and power supplies. This 24VDC axial fan measures 60 x 60 mm across the frame and is listed at 5000 rpm with a 2.64 W electrical input.

24 60*60*15 32.98 - 2.64 5000 37
AFB1224VH | Delta Electronics 24VDC 5.52W Axial Fan for Server and Power Supply Cooling

For power-supply enclosures, AFB1224VH combines 24VDC axial airflow with a 25 mm-deep frame. Rated at 3100 rpm and 5.52 W, this 120 mm fan offers a shallower format than the 38 mm models in the range.

24 120*120*25 176.307 - 5.52 3100 44.5
AFB1224SHE | Delta Electronics 24VDC 12W Axial Fan for Server and Power Supply Cooling

The AFB1224SHE is a 24VDC axial fan for server and power-supply cooling. Its 120 x 120 x 38 mm frame houses a 3700 rpm rotor, with a listed maximum airflow of 258 m3/h and 12 W input power.

24 120*120*38 258 - 12 3700 53
W3G910-LU39-C3 | ebm-papst 3~380-480V EC Axial Fan for Data Center Cooling

Developed for Data Center Cooling, the ebm-papst W3G910-LU39-C3 is a 380-480V EC axial fan, showing 910 mm dimensions for installation planning. It provides a traceable selection parameter.

3`380-480 910 - - - - -
W3G800-LU40-C3 | ebm-papst 3~380-480V 2100W EC Axial Fan for Data Center Cooling

Suited to Data Center Cooling, ebm-papst W3G800-LU40-C3 is a 380-480V EC axial fan, with a focus on a listed airflow of 29,175 m³/h. It supports an evidence-based shortlist. Its documented data supports integration planning.

3`380-480 800 29175 290 2100 1000 83
W3G800-GO84-01/F05 | ebm-papst 400V 514W EC Axial Fan for Data Center Cooling

Deployed in Data Center Cooling, the ebm-papst W3G800-GO84-01/F05 is a 400 V EC axial fan, for which the table lists a listed acoustic value of 43 dB. This supports technical purchasing review.

400 800 18480 110 514 735 43
S6E630-AN01-01 | ebm-papst 230V 600W AC Axial Fan for Data Center Cooling

Intended for Data Center Cooling, ebm-papst S6E630-AN01-01 is a 230 V AC axial fan, offering a documented speed of 860 rpm. This enables specification-led selection. Its documented data supports integration planning.

230 630 6705 100 600 860 -
R4D560-AQ03-01 | ebm-papst 400V 2380W Centrifugal Fan for Data Center

Engineered around Data Center, the ebm-papst R4D560-AQ03-01 is a 400 V AC backward-curved centrifugal fan, centered on a listed airflow of 11,700 m³/h. The data helps compare K-series variants.

400 450 11700 720 2380 1365 -
R3G630-PC08-03 | ebm-papst 3~380-480V 4250W Centrifugal Fan for Data Center

Engineered around Data Center, the ebm-papst R3G630-PC08-03 is a 380-480V EC backward-curved centrifugal fan, distinguished by a listed pressure capability of 1,000 Pa. The rating clarifies its operating profile.

3`380-480 630 12470 1000 4250 1500 74
Showing
761-780
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 32 33 34 35 36 37 38 39 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.