1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
AGE09225B24J | Delta Electronics 12VDC DC Fan for Electronic Equipment and Custom System Cooling

AGE09225B24J is a 24VDC brushless axial fan for electronic equipment cooling. The supplied Crown AGE datasheet identifies a two-ball-bearing option in the 92 x 92 x 25 mm frame, rated at 2100 rpm.

12 92*92*25 129.37 87.5 - 4200 49
AFB0424HB | Delta Electronics 24VDC 1.92W Axial Fan for Server and Power Supply Cooling

At a listed 7000 rpm, AFB0424HB provides a different speed option within the 40 mm axial fan range. It operates on 24VDC for server and power-supply cooling, with a 15 mm body depth and 1.92 W input.

24 40*40*15 16 - 1.92 7000 28.5
FFB0412SHN-F00 | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling

FFB0412SHN-F00 combines 12VDC axial fan cooling with 267.8 Pa listed maximum static pressure. Intended for servers and telecom hardware, it uses a 40 x 40 x 28 mm frame and a 13000 rpm speed rating.

12 40x40x28 40.3 267.8 6 13000 54.5
AGC05015B24J | Delta Electronics 24VDC DC Fan for Electronic Equipment and Custom System Cooling

The AGC05015B24J is a 24VDC brushless fan listed for electronic equipment and custom cooling systems. A 50 x 50 x 15 mm envelope is its documented fit characteristic; interface details require confirmation.

24 50*50*15 - - - - -
AFB0912HD | Delta Electronics 12VDC 1.92W Axial Fan for Server and Power Supply Cooling

With a 1.92 W input rating, AFB0912HD offers a modest electrical load for server and power-supply ventilation. This 12VDC axial fan has a 92 x 92 x 20 mm frame and a listed operating speed of 2700 rpm.

12 92*92*20 91.8 34.3 1.92 2700 35
AFB0924VH | Delta Electronics 24VDC 5.28W Axial Fan for Server and Power Supply Cooling

A 25 mm-deep, 92 mm frame makes AFB0924VH a defined fit for server or power-supply ventilation. The 24VDC axial fan is specified at 3800 rpm, with 115 m3/h maximum airflow and 5.28 W listed input.

24 92*92*25 115 - 5.28 3800 45
AFB1212SHE | Delta Electronics 12VDC 12.6W Axial Fan for Server and Power Supply Cooling

AFB1212SHE pairs 12VDC axial fan operation with a listed 142.2 Pa maximum static pressure. For server and power-supply cooling, its 120 x 120 x 38 mm assembly runs at 3700 rpm with a 12.6 W input rating.

12 120x120x38 258.1 142.2 12.6 3700 53
AFB0412SHB | Delta Electronics 12VDC 3W Axial Fan for Server, Storage and Power Supply Cooling

The AFB0412SHB uses a 12VDC axial fan design in a 40 x 40 x 15 mm frame for server and storage cooling. Its 11000 rpm rotor and 3 W listed input define a high-speed option within this compact size class.

12 40*40*15 8.7 16 3 11000 41.5
BFN0724SS-01 | Delta Electronics 24VDC 36W Centrifugal Blower for Electronic Equipment Cooling

A 17300 rpm rating sets BFN0724SS-01 apart within the supplied blower list. This 24VDC centrifugal blower is intended for electronic equipment and ducted local cooling, using a 70 x 70 x 25 mm body.

24 70x70x25 30.4 4897.1 36 17300 38
BFB0512HHA-C | Delta Electronics 12VDC 1.92W Centrifugal Blower for Electronic Equipment Cooling

BFB0512HHA-C is a 12VDC centrifugal blower for local cooling inside electronic equipment. Its directed-airflow format is specified at 5900 rpm, with 196.8 Pa maximum static pressure and 1.92 W input.

12 50*50 6.8 196.8 1.92 5900 37.5
AFB0624LB | Delta Electronics 24VDC 0.96W Axial Fan for Server and Power Supply Cooling

Low listed input is the distinguishing point of AFB0624LB: 0.96 W at 24VDC. This axial fan serves power-supply and server enclosures in a 60 x 60 x 15 mm format, with a 3000 rpm speed rating.

24 60*60*15 19.6 21.7 0.96 3000 24
FFB0412VHN-F00 | Delta Electronics 12VDC 1.92W Axial Fan for Server and Telecom Cooling

For small telecom housings, FFB0412VHN-F00 combines a 40 mm axial footprint with a 28 mm depth. The 12VDC fan is listed at 9500 rpm and 1.92 W, with maximum static pressure specified as 126.8 Pa.

12 40x40x28 26.5 126.8 1.92 9500 45
AFB0524HHB | Delta Electronics 24VDC 1.92W Axial Fan for Server and Power Supply Cooling

AFB0524HHB provides a 50 x 50 x 15 mm axial fan package for power supplies and server electronics. Operating from 24VDC, it lists a 1.92 W input and a maximum static pressure of 78.5 Pa at its rated setup.

24 50*50*15 27.6 78.5 1.92 6400 36
AFB1224VHEVHW | Delta Electronics 24VDC 9.12W Axial Fan for Server and Power Supply Cooling

A 3200 rpm rating gives AFB1224VHEVHW a different operating point from faster 120 mm models. This 24VDC axial fan is intended for server and power-supply cooling, with 9.12 W input and a 38 mm depth.

24 120*120*38 221 - 9.12 3200 48
AFB0624SH-A | Delta Electronics 24VDC 4.08W Axial Fan for Server and Power Supply Cooling

Server ventilation with AFB0624SH-A is based on a 24VDC axial fan motor and 60 x 60 x 25 mm frame. A 6000 rpm rating and 4.08 W listed input distinguish this model from the faster EH variants in the list.

24 60*60*25 58.055 - 4.08 6000 44.5
FFB0824EHEYWR | Delta Electronics 24VDC 12W Axial Fan for Server and Telecommunications Cooling

The 80 x 80 x 38 mm FFB0824EHEYWR is a 24VDC axial fan for servers and telecom equipment. Rated at 5700 rpm, it lists 136.34 m3/h maximum airflow; the full suffix identifies the required configuration.

24 80*80*38 136.34 - 12 5700 52.5
AFB0912VH | Delta Electronics 12VDC 4.8W Axial Fan for Server and Power Supply Cooling

AFB0912VH offers a 92 mm axial fan format for server and power-supply cooling on 12VDC. Its listed 4.8 W input accompanies 3800 rpm operation and 115.26 m3/h maximum airflow in a 25 mm-deep body.

12 92*92*25 115.26 - 4.8 3800 45
AFB1224EHEX4A | Delta Electronics 24VDC 20.4W Axial Fan for Server and Power Supply Cooling

For server chassis requiring a 120 mm fan, AFB1224EHEX4A combines 24VDC axial operation with 361.42 m3/h listed maximum airflow. The 38 mm-deep assembly is specified at 4600 rpm and 20.4 W input.

24 120*120*38 361.42 - 20.4 4600 58.5
FFB0412SHN7CA | Delta Electronics 12VDC 6W Axial Fan for Server and Telecommunications Cooling

FFB0412SHN7CA places a 13000 rpm axial fan rotor in a 40 x 40 x 28 mm housing. Intended for server and telecom cooling, this 12VDC model has a listed 6 W input and 40.8 m3/h maximum airflow.

12 40*40*28 40.8 - 6 13000 54.5
AFB0624EH-A | Delta Electronics 24VDC 5.76W Axial Fan for Server and Power Supply Cooling

A 65.195 m3/h maximum airflow rating separates AFB0624EH-A from lower-output 60 mm options in the supplied list. This 24VDC axial fan supports server and power-supply cooling in a 25 mm-deep housing.

24 60*60*25 65.195 - 5.76 6800 46.5
Showing
741-760
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-816
of 816
1 2 ... 32 33 34 35 36 37 38 39 40 41
GO page

About Data Center Cooling

Data center cooling fans are specialized ventilation components engineered to maintain the precise temperature and humidity requirements of modern computing infrastructure. As data centers grow in density with higher TDP processors and accelerated adoption of AI and HPC workloads, cooling fan performance and energy efficiency have become critical operational concerns. Data center cooling fans serve three primary architectural roles: server-level fans (120mm DC axial fans mounted in server chassis for direct component cooling), rack-level cooling (inline or roof-mounted EC fans for hot-aisle containment systems), and facility-level HVAC fans (air handling units with EC backward curved centrifugal blowers for building-wide circulation). Key design requirements for data center fans include: reliability (MTBF typically exceeding 100,000 hours), quiet operation (dBA levels for occupied spaces), EC technology for energy efficiency and variable speed, PWM or Modbus control for intelligent thermal management, and hot-swap capability for critical systems. Leading manufacturers include ebm-papst, ZIEHL-ABEGG, Rosenberg, Sanyo Denki, and SUNON. Hengrui supplies data center cooling fans with cross-reference tools, competitive pricing, and engineering consultation.

How to Select the Right Data Center Cooling

The most reliable way to specify data Center Cooling is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 816 products are available in this category today.

Typical Applications and Use Cases for Data Center Cooling

The daily work of our sales engineers is built around data Center Cooling used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying Data Center Cooling

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Do you have data Center Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 816 products in this category are listed online.

Can you replace my existing data Center Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.