| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() PFB0924DHEP0 | Delta Electronics 24VDC 34.8W Axial Fan for Industrial Control Cabinet Cooling Pressure is a key selection point for PFB0924DHEP0: the listed maximum is 453.2 Pa. This 24VDC axial fan serves industrial control-cabinet cooling in a 92 x 92 x 38 mm package rated at 8000 rpm. |
24 | 92*92*38 | 297.4 | 453.2 | 34.8 | 8000 | 66.5 | |
![]() FFB0812EHE | Delta Electronics 12VDC 10.8W Axial Fan for Server and Telecommunications Cooling For server airflow in an 80 mm frame, FFB0812EHE uses a 38 mm-deep axial design. The 12VDC fan has a 5700 rpm rating and a listed maximum airflow of 136 m3/h, with 10.8 W input power specified. |
12 | 80*80*38 | 136 | - | 10.8 | 5700 | 52.5 | |
![]() FFB0924EHE | Delta Electronics 24VDC 12W Axial Fan for Server and Telecommunications Cooling FFB0924EHE combines a 92 x 92 x 38 mm axial fan assembly with 24VDC operation for telecom and server cooling. Its listed 187 m3/h maximum airflow is paired with a 4800 rpm speed and 12 W input. |
24 | 92*92*38 | 187 | 17 | 12 | 4800 | 55 | |
![]() AFB0712VHD | Delta Electronics 12VDC 4.2W Axial Fan for Server and Power Supply Cooling The 20 mm depth of AFB0712VHD suits shallow server or power-supply enclosures. Running on 12VDC, this 70 mm axial fan is specified at 5000 rpm and 4.2 W, with 79.73 m3/h maximum airflow listed. |
12 | 70*70*20 | 79.73 | - | 4.2 | 5000 | 35 | |
![]() QFR0624GHP0 | Delta Electronics 24VDC 3.84W Axial Fan for Industrial Automation Cooling At 7600 rpm, QFR0624GHP0 offers a high-speed 60 mm axial fan format for industrial automation cooling. It operates on 24VDC in a 25 mm-deep frame, with a listed 3.84 W input for electrical integration. |
24 | 60*60*25 | 20.5 | 14.4 | 3.84 | 7600 | 47 | |
![]() AFB0924SH-A | Delta Electronics 24VDC 9.6W Axial Fan for Server and Power Supply Cooling AFB0924SH-A is a 24VDC axial fan intended for server and power-supply ventilation. Its 92 x 92 x 25 mm housing accommodates a 4800 rpm rotor, while the specified 9.6 W input helps define supply sizing. |
24 | 92*92*25 | 60.3 | 13.5 | 9.6 | 4800 | 53 | |
![]() AFB0724VH-A | Delta Electronics 24VDC 6.48W Axial Fan for Server and Power Supply Cooling In the 70 mm class, AFB0724VH-A pairs a 25 mm frame depth with 5500 rpm operation. This 24VDC axial fan is listed for server and power-supply cooling, with a maximum airflow rating of 88.349 m3/h. |
24 | 70*70*25 | 88.349 | - | 6.48 | 5500 | 47.5 | |
![]() EFB0424VHD | Delta Electronics 24VDC 2.16W Axial Fan for Industrial Equipment Cooling EFB0424VHD provides axial fan ventilation for industrial electronics from a 24VDC supply. A 40 x 40 x 20 mm package and 2.16 W input distinguish its electrical and mechanical fit for equipment cooling. |
24 | 40*40*20 | 17.17 | - | 2.16 | 9000 | 32.5 | |
![]() FFB0424VHN | Delta Electronics 24VDC 2.4W Axial Fan for Server and Telecommunications Cooling Server and telecom enclosures needing a 40 mm footprint can consider FFB0424VHN. This 24VDC axial fan uses a deeper 28 mm body and a 9500 rpm rotor; listed input power is 2.4 W for this configuration. |
24 | 40*40*28 | 26.843 | - | 2.4 | 9500 | 45 | |
![]() AFB0524VHD | Delta Electronics 24VDC 2.4W Axial Fan for Server and Power Supply Cooling A 75.51 Pa maximum static-pressure rating characterizes AFB0524VHD. Intended for server or power-supply cooling, the 24VDC axial fan uses a 50 x 50 x 20 mm body and is specified to run at 7000 rpm. |
24 | 50x50x20 | 34.5 | 75.51 | 2.4 | 7000 | 40.5 | |
![]() AFB0424SHB | Delta Electronics 24VDC 2.88W Axial Fan for Server and Power Supply Cooling AFB0424SHB fits a 40 x 40 x 15 mm space in servers or power supplies. Its 24VDC axial fan design is specified at 11000 rpm, making rotor speed the defining selection point within this small frame size. |
24 | 40*40*15 | 25.211 | - | 2.88 | 11000 | 41.5 | |
![]() PFB1224UHE | Delta Electronics 24VDC 48W Axial Fan for Industrial Control Cabinet Cooling With 430 m3/h listed maximum airflow, PFB1224UHE addresses industrial control-cabinet cooling. This 24VDC axial fan combines a 120 x 120 x 38 mm frame with a 5500 rpm speed and 48 W input rating. |
24 | 120*120*38 | 430 | - | 48 | 5500 | 66.5 | |
![]() FFB0624EHE | Delta Electronics 24VDC 9.12W Axial Fan for Server and Telecommunications Cooling FFB0624EHE brings a 38 mm-deep, 60 mm axial format to server and telecom cooling. The 24VDC model runs at 8000 rpm, with 85.34 m3/h maximum airflow specified for this higher-speed enclosure fan. |
24 | 60*60*38 | 85.34 | - | 9.12 | 8000 | 54.5 | |
![]() AFB0624VHBWPE | Delta Electronics 24VDC 2.64W Axial Fan for Server and Power Supply Cooling A 15 mm profile distinguishes AFB0624VHBWPE for server chassis and power supplies. This 24VDC axial fan measures 60 x 60 mm across the frame and is listed at 5000 rpm with a 2.64 W electrical input. |
24 | 60*60*15 | 32.98 | - | 2.64 | 5000 | 37 | |
![]() EFB0412VHD-F00 | Delta Electronics 12VDC 1.44W Axial Fan for Industrial Equipment Cooling Industrial electronics can use the EFB0412VHD-F00, a 12VDC axial fan with a 40 x 40 x 20 mm envelope. Its 9000 rpm speed and listed 1.44 W input define a compact cooling option for equipment housings. |
12 | 40*40*20 | 17.17 | - | 1.44 | 9000 | 32.5 | |
![]() AFB1224VH | Delta Electronics 24VDC 5.52W Axial Fan for Server and Power Supply Cooling For power-supply enclosures, AFB1224VH combines 24VDC axial airflow with a 25 mm-deep frame. Rated at 3100 rpm and 5.52 W, this 120 mm fan offers a shallower format than the 38 mm models in the range. |
24 | 120*120*25 | 176.307 | - | 5.52 | 3100 | 44.5 | |
![]() AFB1224SHE | Delta Electronics 24VDC 12W Axial Fan for Server and Power Supply Cooling The AFB1224SHE is a 24VDC axial fan for server and power-supply cooling. Its 120 x 120 x 38 mm frame houses a 3700 rpm rotor, with a listed maximum airflow of 258 m3/h and 12 W input power. |
24 | 120*120*38 | 258 | - | 12 | 3700 | 53 |
Choosing the right DC FAN starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.
Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.
Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.
Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 197 items in this category ready to compare.
DC FAN appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.
One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.
For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.
Whether the project involves new equipment or the replacement of installed Delta units, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.