Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
THA1-7556MX-TP-N/O | IKURA AC Axial Fan for Electrical Cabinets

THA1-7556MX-TP-N/O brings a axial fan format and 220 VAC rating to ventilation systems. Its representative supplied feature is a 172*150*55 mm size specified in the upload data. Key data also includes 43 W input power for the listed electrical version. Selection focus: replacement fit during replacement review.

220 172*150*55 - - 43 - -
UHS4556M | IKURA 220V 20W AC Axial Fan for Electrical Cabinets

UHS4556M is a 220 VAC axial fan for ventilation systems. Its main supplied feature is 73.5 Pa maximum pressure stated for this model. It also lists a 120*120*38 mm size specified in the upload data. Review service access for replacement review. Use the complete model code and supplied parameters when confirming the final installation.

220 120*120*38 144 73.5 20 - 42
U7556KX-TP | IKURA 230V 40W AC Axial Fan for Electrical Cabinets

U7556KX-TP addresses ventilation systems through a 230 VAC axial fan design. Its representative supplied feature is a 172*150*55 mm size specified in the upload data. Key data also includes 390 m³/h maximum airflow stated for this model and 157.6 Pa maximum pressure stated for this model. Selection focus: duct connection during replacement review.

230 172*150*55 390 157.6 40 3200 53
THA1-7556X-TP N/O | IKURA AC Axial Fan for Electrical Cabinets

Selected for ventilation systems, THA1-7556X-TP N/O uses a axial fan arrangement with 200 VAC. Its representative supplied feature is 40 W input power for the listed electrical version. Selection focus: cooling margin during replacement review. Use the complete model code and supplied parameters when confirming the final installation.

200 - - - 40 - -
THA1-350P049-2TP-N/O | IKURA AC Axial Fan for Electrical Cabinets

THA1-350P049-2TP-N/O is a 100 VAC axial fan for ventilation systems. Its main supplied feature is ball-bearing construction stated in the supplied reference. It also lists a 350 mm size specified in the upload data. Review acoustic limit for replacement review. Check the exact variant before ordering.

100 350 - - 95 - -
6250MG1-TP | IKURA 220V 40W AC Axial Fan for Electrical Cabinets

Within ventilation systems, 6250MG1-TP operates as a 220 VAC axial fan. Its representative supplied feature is a 160*160*55 mm size specified in the upload data. Key data also includes 40 W input power for the listed electrical version and 2800 rpm rated speed in the supplied parameter row. Selection focus: control method during replacement review.

220 160*160*55 - - 40 2800 -
350P049-2TP | IKURA 100V 155W AC Axial Fan for Electrical Cabinets

350P049-2TP is a 100 VAC axial fan for ventilation systems. Its main supplied feature is 155 W input power for the listed electrical version. It also lists a Φ350 mm size specified in the upload data. Review electrical supply for replacement review. Use the complete model code and supplied parameters when confirming the final installation.

100 Φ350 1800 157.3 155 1600 57
2750MTP-15 | IKURA 37W AC Axial Fan for Electrical Cabinets

2750MTP-15 supports ventilation systems as a axial fan, with 230 VAC listed in the supplied data. Its representative supplied feature is 37 W input power for the listed electrical version. Selection focus: motor interface during replacement review. Use the complete model code and supplied parameters when confirming the final installation.

230 - - - 37 - -
175P5H-TP-1 | IKURA 200V 86W AC Axial Fan for Electrical Cabinets

Designed for ventilation systems, 175P5H-TP-1 provides a axial fan platform rated at 200 VAC. Its representative supplied feature is 86 W input power for the listed electrical version. Selection focus: pressure requirement during replacement review. Use the complete model code and supplied parameters when confirming the final installation.

200 - - - 86 - -
THA1-7506X-TP N/O | IKURA AC Axial Fan for Electrical Cabinets

THA1-7506X-TP N/O is a 100 VAC axial fan for ventilation systems. Its main supplied feature is a 172*150*55 mm size specified in the upload data. It also lists 330.31 m³/h maximum airflow stated for this model. Review airflow path for replacement review. Use the complete model code and supplied parameters when confirming the final installation.

100 172*150*55 330.31 - 43 2750 49
Showing
1-10
1-10
of 10

About IKURA

As a professional industrial fan and blower supplier, we have supplied IKURA products to customers for over 20 years, covering the full journey from model selection and quotation to delivery and after-sales support.

The products are widely used in HVAC and ventilation, refrigeration and cold chain equipment, data center cooling and many other fields. Share your required airflow, static pressure and installation dimensions, and we will match them against the available series and confirm stock or lead time in one reply.

Replacement supply is one of our core strengths. For discontinued or long-lead-time IKURA models, we check frame size, speed, power and curves one by one and deliver a drop-in alternative proposal, which has helped factories, equipment builders and facility operators avoid costly downtime.

Working with us means one contact for the whole lifecycle of your IKURA equipment: technical selection support before you buy, datasheets and dimension drawings for engineering review, flexible quantities from a single sample to bulk orders, and responsive after-sales assistance if anything needs attention in service.

How to Select the Right IKURA

Choosing the right IKURA starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.

Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.

Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.

Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 10 items in this category ready to compare.

Typical Applications and Use Cases for IKURA

IKURA appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.

One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.

For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.

Whether the project involves new equipment or the replacement of installed IKURA units, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.

Frequently Asked Questions About Buying IKURA

Do you support customized or OEM versions of IKURA?

Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.

What warranty and after-sales support do you provide?

Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.

What technical documentation do you provide before purchase?

Datasheets, performance curves, dimension drawings and certification files (UL, CE, RoHS where applicable) are available on request before you buy — we believe a purchase order should follow a verified selection, not replace it. For project tenders we can also provide product comparison tables that put the candidate models side by side on the parameters you care about.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.