1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-896
of 896
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
A2E200-AF02-01 | ebm-papst 230V 50W AC Axial Fan for Motor Cooling

A 230 V AC axial fan for variable-frequency motor cooling, the ebm-papst A2E200-AF02-01 delivers model-specific cooling performance. Its 740 m³/h airflow, 88 Pa pressure, 2740 RPM supports efficient ventilation where reliable airflow and compact integration are important.

230 200 740 88 50 2740 -
A2E170-AF23-01 | ebm-papst 230V 47W AC Axial Fan for Motor Cooling

The ebm-papst A2E170-AF23-01, a 230 V AC axial fan, is intended for industrial motor cooling. Listed performance includes 2700 RPM, giving designers a clear basis for checking airflow, mounting and electrical compatibility.

230 170 - - 47 2700 -
A2D300-AD20-49 | ebm-papst 230V 220W AC Axial Fan for Motor Cooling

Built for industrial motor cooling, the ebm-papst A2D300-AD20-49 is a 230 V AC axial fan. Its combination of 1905 m³/h airflow, 2650 RPM is intended to maintain controlled airflow and reduce thermal stress in demanding installations.

230 300 1905 - 220 2650 -
A2D250-AI02-01 | ebm-papst 230V 140W AC Axial Fan for Industrial Cooling

ebm-papst A2D250-AI02-01 is specified as an AC axial fan using a 230 V supply, suited to industrial cooling. The available rating of 1950 m³/h airflow, 125 Pa pressure, 2650 RPM enables model-specific airflow matching in OEM equipment and maintenance replacements.

230 250 1950 125 140 2650 -
A2D250-AD26-05 | ebm-papst 400V 137W AC Axial Fan for Motor Cooling

For industrial motor cooling, the ebm-papst A2D250-AD26-05 provides a 400 V AC axial fan solution. Performance data of 1265 m³/h airflow, 2585 RPM supports practical selection for continuous ventilation, component cooling and replacement planning.

400 250 1265 - 137 2585 -
A2D250-AA26-80 | ebm-papst 400V 140W AC Axial Fan for Motor Cooling

The A2D250-AA26-80 from ebm-papst combines 400 V operation with an AC axial fan configuration for servo motor cooling. Its documented 2520 RPM helps engineers compare the fan with the system resistance, installation space and cooling demand.

400 250 - - 140 2520 -
A2D250-AA02-02 | ebm-papst 400V 110W AC Axial Fan for Motor Cooling

Designed as an AC axial fan, the ebm-papst A2D250-AA02-02 operates at 400 V for spindle motor cooling. With 1205 m³/h airflow, 111 Pa pressure, 2650 RPM, it provides directed airflow for space-conscious equipment and thermal-management assemblies.

400 250 1205 111 110 2650 -
A2D250-AA02-01 | ebm-papst 400V 110W AC Axial Fan for Motor Cooling

The ebm-papst A2D250-AA02-01 is a 400 V AC axial fan developed for industrial motor cooling. Its listed performance—1720 m³/h airflow, 120 Pa pressure, 2650 RPM—supports stable heat removal and dependable operation when matched to the required duty point.

400 250 1720 120 110 2650 -
A2D210-AB10-05 | ebm-papst 400V 89W AC Axial Fan for Motor Cooling

A 400 V AC axial fan for industrial motor cooling, the ebm-papst A2D210-AB10-05 delivers model-specific cooling performance. Its 780 m³/h airflow, 2750 RPM supports efficient ventilation where reliable airflow and compact integration are important.

400 210 780 - 89 2750 -
A2D200-AH18-01 | ebm-papst 400V 70W AC Axial Fan for Industrial Cooling

The ebm-papst A2D200-AH18-01, a 400 V AC axial fan, is intended for industrial cooling. Listed performance includes 140 Pa pressure, 2900 RPM, giving designers a clear basis for checking airflow, mounting and electrical compatibility.

400 200 - 140 70 2900 -
A2D200-AA02-02 | ebm-papst 230V 53W AC Axial Fan for Motor Cooling

Built for industrial motor cooling, the ebm-papst A2D200-AA02-02 is a 230 V AC axial fan. Its combination of 840 m³/h airflow, 2800 RPM is intended to maintain controlled airflow and reduce thermal stress in demanding installations.

230 200 840 - 53 2800 67
A2D200-AA02-01 | ebm-papst 400V 70W AC Axial Fan for Motor Cooling

ebm-papst A2D200-AA02-01 is specified as an AC axial fan using a 400 V supply, suited to industrial motor cooling. The available rating of 910 m³/h airflow, 110 Pa pressure, 3150 RPM enables model-specific airflow matching in OEM equipment and maintenance replacements.

400 200 910 110 70 3150 -
A2D170-AA04-02 | ebm-papst 400V 45W AC Axial Fan for Motor Cooling

For industrial motor cooling, the ebm-papst A2D170-AA04-02 provides a 400 V AC axial fan solution. Performance data of 535 m³/h airflow, 80 Pa pressure, 2750 RPM supports practical selection for continuous ventilation, component cooling and replacement planning.

400 170 535 80 45 2750 -
A2D170-AA04-01 | ebm-papst 400V 45W AC Axial Fan for Motor Cooling

The A2D170-AA04-01 from ebm-papst combines 400 V operation with an AC axial fan configuration for variable-frequency motor cooling. Its documented 470 m³/h airflow, 60 Pa pressure, 2750 RPM helps engineers compare the fan with the system resistance, installation space and cooling demand.

400 170 470 60 45 2750 -
A2D160-AB22-06 | ebm-papst 480V 43W AC Axial Fan for Motor Cooling

Designed as an AC axial fan, the ebm-papst A2D160-AB22-06 operates at 480 V for industrial motor cooling. With 155 m³/h airflow, 165 Pa pressure, 3350 RPM, it provides directed airflow for space-conscious equipment and thermal-management assemblies.

480 160 155 165 43 3350 -
A2D160-AA22-05 | ebm-papst 460V 52W AC Axial Fan for Motor Cooling

The ebm-papst A2D160-AA22-05 is a 460 V AC axial fan developed for spindle motor cooling. Its listed performance—400 m³/h airflow, 258 Pa pressure, 3350 RPM—supports stable heat removal and dependable operation when matched to the required duty point.

460 160 400 258 52 3350 -
Showing
881-896
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-896
of 896
1 2 ... 36 37 38 39 40 41 42 43 44 45
GO page

About Industrial Cooling

Industrial cooling and process ventilation

How to Select the Right Industrial Cooling

Choosing the right industrial Cooling starts with the operating point rather than the model name. Define the airflow you actually need in CFM or m³/h and the static pressure the fan must overcome, then look for units whose performance curves pass through that point with a safety margin instead of sitting at the edge of the curve.

Pay attention to the electrical details early. DC fans typically run on 12/24/48 V and integrate easily with control boards, while AC fans suit 115/230 V fixed-speed installations. If the airflow must change with load, choose EC technology with PWM or analog control and, where monitoring matters, a tachometer output so the controller can detect fan failure.

Environment and compliance come next. Match the IP rating to dust and moisture exposure, prefer ball bearings wherever the fan runs hot, vertically or around the clock, and confirm certifications — UL, CE, RoHS — against your destination market. Setting the acoustic limit in dBA early prevents late-stage redesign when the first unit proves too loud.

Finally, compare candidates on total delivery risk, not only on price: confirm stock for the quantity you need, check the lead time for the next batch, and ask for datasheets and dimension drawings before committing. Our team cross-checks curves, dimensions and electrical data for you before quotation There are currently 896 items in this category ready to compare.

Typical Applications and Use Cases for Industrial Cooling

Industrial Cooling appear in almost every sector where heat or stale air must be moved reliably. Typical environments include server rooms and data centers, refrigeration condensers and cold-store evaporators, HVAC air handling units, telecom cabinets, medical and laboratory equipment, welding and CNC machine enclosures, and renewable-energy power cabinets. In each of these settings the fan is a critical component: its failure stops production, damages stored goods or forces expensive emergency downtime.

One recurring scenario comes from control cabinet retrofits: the original fan is obsolete, the mounting hole pattern cannot change, and downtime is measured in hours. We match the old unit against current series by frame size, airflow and noise, propose the closest drop-in alternative, and ship with a datasheet that lets the electrician connect it without redesign.

For cold storage operators the pain is simple: a failed evaporator or condenser fan must be replaced now, not after a six-week import cycle. Matching blade diameter, speed and protection class against stocked equivalents lets us restore cooling capacity within days, which is why replacement supply has become a core part of this category for us.

Whether you are building new equipment or maintaining an installed base, the workflow is the same: send us the operating point and constraints, and we return a validated selection with datasheets, curves and a clear lead time.

Frequently Asked Questions About Buying Industrial Cooling

Do you have industrial Cooling in stock and how fast can you deliver?

Common series and mainstream voltage versions are normally in stock and can ship within a few working days; specialized or customized variants are produced to order and typically require additional production time. Send us the exact model or the required parameters and we will confirm stock, unit price and the earliest shipment date in one reply Currently 896 products in this category are listed online.

Can you replace my existing industrial Cooling from another supplier or a discontinued model?

Yes. Replacement supply is one of our core services: we cross-reference the mounting dimensions, voltage, speed and performance curve of your installed unit and propose the closest current-series equivalent. Where the frame or connector differs slightly, we state the difference clearly before you order, so the replacement installs without surprises.

Can I order a single piece or request a sample before a bulk purchase?

Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.