| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() FN080-ADQ.6N.V7P5 174391 | ZIEHL-ABEGG 3~400VAC 1050/780W AC Axial Fan for renewable energy FN080-ADQ.6N.V7P5 174391 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is two-plane dynamic balancing for stable fan operation. It also lists a 7-blade impeller identified for this model. Review procurement specification for retrofit assessment. |
3~400 | 800 | 11750 | 80 | 1050/780 | - | - | |
![]() FN071-SDS.6F.V7P1 141783 | ZIEHL-ABEGG 3~400VAC 940/620W AC Axial Fan for renewable energy FN071-SDS.6F.V7P1 141783 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is full-range speed-control capability stated for the series. It also lists a 7-blade impeller identified for this model. Review housing geometry for retrofit assessment. |
3~400 | 710 | 9388 | 123 | 940/620 | - | - | |
![]() FN071-SDK.6K.V7P1 141774 | ZIEHL-ABEGG 3~400VAC 1000/720W AC Axial Fan for renewable energy FN071-SDK.6K.V7P1 141774 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is energy-efficient aerodynamic design highlighted in the supplied series data. It also lists a 7-blade impeller identified for this model. Review controller compatibility for retrofit assessment. |
3~400 | 710 | 9308 | 126 | 1000/720 | - | - | |
![]() FN063-VDQ.6N.V7P7 170696 | ZIEHL-ABEGG 3~400VAC 2700/1750W AC Axial Fan for renewable energy FN063-VDQ.6N.V7P7 170696 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is low-noise aerodynamic design documented for the series. It also lists a 7-blade impeller identified for this model. Review air direction for retrofit assessment. |
3~400 | 630 | 13670 | 241 | 2700/1750 | - | - | |
![]() FN063-VDS.6N.V7P7 169342 | ZIEHL-ABEGG 3~400VAC 2700W AC Axial Fan for renewable energy FN063-VDS.6N.V7P7 169342 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is 1330 rpm rated speed in the supplied parameter row. It also lists a 7-blade impeller identified for this model. Review performance curve for retrofit assessment. |
3~400 | 630 | 20000 | 475 | 2700 | 1330 | - | |
![]() FN063-VDW.6K.A7P5 165403 | ZIEHL-ABEGG 3~400VAC 1500/1100W AC Axial Fan for renewable energy FN063-VDW.6K.A7P5 165403 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is a dual-speed motor configuration identified for this model. It also lists a 7-blade impeller identified for this model. Review maintenance access for retrofit assessment. |
3~400 | 630 | - | - | 1500/1100 | - | - | |
![]() FN063-VDK.6K.V7P5 165402 | ZIEHL-ABEGG 3~400VAC 1500/1100W AC Axial Fan for renewable energy FN063-VDK.6K.V7P5 165402 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is a 7-blade impeller identified for this model. It also lists a 630 mm size specified in the upload data. Review equipment interface for retrofit assessment. |
3~400 | 630 | - | - | 1500/1100 | - | - | |
![]() FN063-SDQ.4I.V7P1 141385 | ZIEHL-ABEGG 3~400VAC 620/440W AC Axial Fan for renewable energy FN063-SDQ.4I.V7P1 141385 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is 7166 m³/h maximum airflow stated for this model. It also lists a 7-blade impeller identified for this model. Review ventilation duty for retrofit assessment. |
3~400 | 630 | 7166 | 100 | 620/440 | - | - | |
![]() FN063-SDS.4I.V7P1 142764 | ZIEHL-ABEGG 3~400VAC 620W AC Axial Fan for renewable energy systems FN063-SDS.4I.V7P1 142764 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is a 630 mm size specified in the upload data. It also lists a 7-blade impeller identified for this model. Review power budget for retrofit assessment. |
3~400 | 630 | 9800 | 79 | 620 | 900 | - | |
![]() FN056-VDQ.4M.V7P2 159445 | ZIEHL-ABEGG 3~400VAC 1050W AC Axial Fan for renewable energy FN056-VDQ.4M.V7P2 159445 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is ECblue motor and integrated-control technology referenced for this model. It also lists a 7-blade impeller identified for this model. Review fan selection for retrofit assessment. |
3~400 | 560 | 11000 | 170 | 1050 | 1280 | - | |
![]() FN056-VDW.4M.A7P2 160379 | ZIEHL-ABEGG 3~400VAC 1350W AC Axial Fan for renewable energy FN056-VDW.4M.A7P2 160379 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is a 560 mm size specified in the upload data. It also lists a 7-blade impeller identified for this model. Review operating point for retrofit assessment. |
3~400 | 560 | 11200 | 200 | 1350 | 1320 | 82 | |
![]() FN056-VDK.4M.V7P2 159443 | ZIEHL-ABEGG 3~400VAC 1350W AC Axial Fan for renewable energy FN056-VDK.4M.V7P2 159443 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is ECblue motor and integrated-control technology referenced for this model. It also lists a 7-blade impeller identified for this model. Review installation clearance for retrofit assessment. |
3~400 | 560 | 10200 | 160 | 1350 | 1320 | 79 | |
![]() FN050-VDQ.4I.V7P1 140322 | ZIEHL-ABEGG 3~400VAC 840W AC Axial Fan for renewable energy systems FN050-VDQ.4I.V7P1 140322 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is a dual-speed motor configuration identified for this model. It also lists a 7-blade impeller identified for this model. Review wiring plan for retrofit assessment. |
3~400 | 500 | 9300 | 200 | 840 | 1340 | 78 | |
![]() FN050-VDW.4I.A7P1 156556 | ZIEHL-ABEGG 3~400VAC 840/540W AC Axial Fan for renewable energy FN050-VDW.4I.A7P1 156556 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is two-plane dynamic balancing for stable fan operation. It also lists a 7-blade impeller identified for this model. Review system resistance for retrofit assessment. |
3~400 | 500 | 6159 | 149 | 840/540 | - | - | |
![]() FN050-VDS.4I.V7P1 140471 | ZIEHL-ABEGG 3~400VAC 840/540W AC Axial Fan for renewable energy FN050-VDS.4I.V7P1 140471 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is a 500 mm size specified in the upload data. It also lists a 7-blade impeller identified for this model. Review replacement fit for retrofit assessment. |
3~400 | 500 | - | - | 840/540 | - | - | |
![]() FN050-VDK.4I.V7P1 140056 | ZIEHL-ABEGG 3~400VAC 840W AC Axial Fan for renewable energy systems FN050-VDK.4I.V7P1 140056 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is energy-efficient aerodynamic design highlighted in the supplied series data. It also lists a 7-blade impeller identified for this model. Review service access for retrofit assessment. |
3~400 | 500 | 8200 | 150 | 840 | 1340 | - | |
![]() FN050-4EK.4I.V7P1 140057 | ZIEHL-ABEGG 1~230VAC 760W AC Axial Fan for renewable energy systems FN050-4EK.4I.V7P1 140057 is a 1~230 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is low-noise aerodynamic design documented for the series. It also lists a 7-blade impeller identified for this model. Review duct connection for retrofit assessment. |
1~230 | 500 | 9800 | 160 | 760 | 1230 | - | |
![]() FN045-VDS.4F.V7P1 160344 | ZIEHL-ABEGG 3~400VAC 540/360W AC Axial Fan for renewable energy FN045-VDS.4F.V7P1 160344 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is a 7-blade impeller identified for this model. It also lists a 450 mm size specified in the upload data. Review cooling margin for retrofit assessment. |
3~400 | 450 | - | - | 540/360 | - | - | |
![]() FN045-VDQ.2F.A7P2 156703 | ZIEHL-ABEGG 3~400VAC 350/220W AC Axial Fan for renewable energy FN045-VDQ.2F.A7P2 156703 is a 3~400 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is a compact construction intended to simplify equipment integration. It also lists a 7-blade impeller identified for this model. Review acoustic limit for retrofit assessment. |
3~400 | 450 | - | - | 350/220 | - | - | |
![]() FN045-4EQ.2F.A7P2 154194 | ZIEHL-ABEGG 1~230VAC 390W AC Axial Fan for renewable energy systems FN045-4EQ.2F.A7P2 154194 is a 1~230 VAC axial fan for chillers, cold-chain equipment, industrial refrigeration. Its main supplied feature is bionic blade geometry developed for efficient, low-noise airflow. It also lists a 7-blade impeller identified for this model. Review control method for retrofit assessment. |
1~230 | 450 | - | - | 390 | - | - |
The most reliable way to specify new Energy is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,013 products are available in this category today.
The daily work of our sales engineers is built around new Energy used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.