1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1013
of 1,013
Download Table
Mfr Part # Rated Voltage(V) Size(mm) Max.Air Flow(m³/h) Max.Pressure(Pa) Input Power(W) Speed(rpm) Noise(db)
K3G190-RD45-03 | ebm-papst 230V 169W EC Centrifugal Fan for Battery Cooling

Designed for Battery Cooling, the ebm-papst K3G190-RD45-03 is a 230 V EC backward-curved centrifugal fan, defined by a documented speed of 4,120 rpm. The value helps verify equipment fit.

230 190 524 - 169 4120 -
G4D355-CM15-XA/F02 | ebm-papst 400V 4380W AC Centrifugal Blower for Wind Turbines

In wind turbines, G4D355-CM15-XA/F02 serves as a 400 V AC centrifugal blower. For selection, its most distinctive listed attribute is a listed 40 dB noise value with 6,620 m³/h airflow.

400 355 6620 400 4380 1320 40
G4D310-DK03-05/F02 | ebm-papst 400V 2180W AC Centrifugal Blower for Wind Inverters

G4D310-DK03-05/F02 is specified as a 400 V AC centrifugal blower for wind inverters. Its standout data point is a 2,180 W input rating with thermal-overload protection. It supports exact-model comparison for OEM sourcing.

400 310 - - 2180 1310 -
G4D200-CL12-01 | ebm-papst 400V 340W AC Centrifugal Blower for Wind Turbines

Designed around wind turbines, G4D200-CL12-01 uses a 400 V AC centrifugal blower platform. Its selection profile is led by 1,270 m³/h airflow with a 340 W input rating. It supports exact-model comparison for OEM sourcing.

400 200 1270 250 340 1550 -
G2E146-DW07-10 | ebm-papst 230V 150W AC Centrifugal Blower for Wind Turbines

In wind turbines, G2E146-DW07-10 serves as a 230 V AC centrifugal blower. IP54 protection with thermal-overload protection is its clearest differentiator in the supplied data.

230 146 380 450 150 1750 -
G2E146-DW07-01 | ebm-papst 230V 140W AC Centrifugal Blower for Wind Turbines

G2E146-DW07-01 is specified as a 230 V AC centrifugal blower for wind turbines. The supplied specifications highlight thermal-overload protection with ball-bearing construction.

230 146 475 399 140 1550 -
D2E146-AP47-79 | ebm-papst 230V 330W AC Centrifugal Blower for Power Cooling

Designed as an AC centrifugal blower, the ebm-papst D2E146-AP47-79 operates at 230 V for wind-power and converter cooling. With 700 m³/h airflow, 400 Pa pressure, it provides directed airflow for space-conscious equipment and thermal-management assemblies.

- - - - - - -
D2E146-AP47-02 | ebm-papst 230V 300W AC Centrifugal Blower for Inverter Cooling

A 230 V AC centrifugal blower for solar inverter cooling, the ebm-papst D2E146-AP47-02 delivers model-specific cooling performance. Its 970 m³/h airflow, 440 Pa pressure supports efficient ventilation where reliable airflow and compact integration are important.

- - - - - - -
D2E133-DM47-01 | ebm-papst 230V 185W AC Centrifugal Blower for Cabinet Cooling

Built for wind-power and converter cooling, the ebm-papst D2E133-DM47-01 is a 230 V AC centrifugal blower. Its combination of 480 m³/h airflow, 400 Pa pressure is intended to maintain controlled airflow and reduce thermal stress in demanding installations.

- - - - - - -
D2E133-AM47-23 | ebm-papst 230V 200W AC Centrifugal Blower for Inverter Cooling

The D2E133-AM47-23 from ebm-papst combines 230 V operation with an AC centrifugal blower configuration for solar inverter cooling. Its documented 710 m³/h airflow, 275 Pa pressure helps engineers compare the fan with the system resistance, installation space and cooling demand.

- - - - - - -
D2E133-AM47-01/A01 | ebm-papst 230V 190W AC Centrifugal Blower for Power Cooling

The ebm-papst D2E133-AM47-01/A01 is a 230 V AC centrifugal blower developed for wind-power and converter cooling. Its listed performance—710 m³/h airflow, 275 Pa pressure—supports stable heat removal and dependable operation when matched to the required duty point.

- - - - - - -
D2E133-AM47-01 | ebm-papst 230V 190W AC Centrifugal Blower for Inverter Cooling

A 230 V AC centrifugal blower for solar inverter cooling, the ebm-papst D2E133-AM47-01 delivers model-specific cooling performance. Its 710 m³/h airflow, 275 Pa pressure supports efficient ventilation where reliable airflow and compact integration are important.

- - - - - - -
A4E350-AP06-33 | ebm-papst 230V 130W AC Axial Fan for EV Charging/Refrigeration

ebm-papst A4E350-AP06-33 is specified as an AC axial fan using a 230 V supply, suited to charging stations and refrigeration equipment. The available rating of 3110 m³/h airflow, 90 Pa pressure, 1400 RPM enables model-specific airflow matching in OEM equipment and maintenance replacements.

230 350 3110 90 130 1400 -
Showing
1001-1013
1-20 21-40 41-60 61-80 81-100 101-120 121-140 141-160 161-180 181-200 201-220 221-240 241-260 261-280 281-300 301-320 321-340 341-360 361-380 381-400 401-420 421-440 441-460 461-480 481-500 501-520 521-540 541-560 561-580 581-600 601-620 621-640 641-660 661-680 681-700 701-720 721-740 741-760 761-780 781-800 801-820 821-840 841-860 861-880 881-900 901-920 921-940 941-960 961-980 981-1000 1001-1013
of 1,013
1 2 ... 42 43 44 45 46 47 48 49 50 51
GO page

About New Energy

New energy and power electronics cooling

How to Select the Right New Energy

The most reliable way to specify new Energy is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.

Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.

Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.

End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,013 products are available in this category today.

Typical Applications and Use Cases for New Energy

The daily work of our sales engineers is built around new Energy used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.

A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.

Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.

From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.

Frequently Asked Questions About Buying New Energy

Can I order a single piece or request a sample before a bulk purchase?

Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.

Do you support customized or OEM versions of new Energy?

Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.

What warranty and after-sales support do you provide?

Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.

Bag

Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.