| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() W3G300-8317087358 | ebm-papst 3~380-480V EC Axial Fan for New Energy Cooling Suited to New Energy Cooling, the ebm-papst W3G300-8317087358 is a 380-480V EC axial fan, with a focus on 300 mm dimensions for installation planning. This supports technical purchasing review. |
3`380-480 | 300 | - | - | - | - | - | |
![]() W3G500-ZQ12-90 | ebm-papst 400V 1600W EC Axial Fan for New Energy Cooling Matched to New Energy Cooling, ebm-papst W3G500-ZQ12-90 is a 400 V EC axial fan, characterized by a listed pressure capability of 440 Pa. It gives buyers a documented reference. Its documented data supports integration planning. |
400 | 500 | 11810 | 440 | 1600 | 1870 | 79 | |
![]() W3G500-XQ12-90 | ebm-papst 3~380-480V 1950W EC Axial Fan for New Energy Cooling Serving New Energy Cooling, the ebm-papst W3G500-XQ12-90 is a 380-480V EC axial fan, whose supplied data highlights a listed pressure capability of 500 Pa. The rating clarifies its operating profile. |
3`380-480 | 500 | 12620 | 500 | 1950 | 1870 | 81 | |
![]() W2S130-BM03-11 | ebm-papst 230V 46W AC Axial Fan for New Energy Cooling Chosen for New Energy Cooling, ebm-papst W2S130-BM03-11 is a 230 V AC axial fan, recognized through a documented 46 W input rating. This supports duty-point selection. Its documented data supports integration planning. |
230 | 172*150*55 | 435 | 80 | 46 | 3050 | - | |
![]() W2E250-HJ52-06 | ebm-papst 230V 135W AC Axial Fan for New Energy Cooling Prepared for New Energy Cooling, ebm-papst W2E250-HJ52-06 is a 230 V AC axial fan, offering a documented speed of 2,650 rpm. This enables specification-led selection. Its documented data supports integration planning. |
230 | 280*280*80 | - | 150 | 135 | 2650 | - | |
![]() W2E250-CE65-01 | ebm-papst 115V 115W AC Axial Fan for New Energy Cooling Serving New Energy Cooling, ebm-papst W2E250-CE65-01 is a 115 V AC axial fan, marked by 250 mm dimensions for installation planning. This helps evaluate the intended duty. Its documented data supports integration planning. |
115 | 250 | - | 150 | 115 | 2550 | - | |
![]() W2E200-HH38-07 | ebm-papst 230V 64W AC Axial Fan for New Energy Cooling Configured for New Energy Cooling, ebm-papst W2E200-HH38-07 is a 230 V AC axial fan, offering a documented 64 W input rating. The figure supports compatibility review. Its documented data supports integration planning. |
230 | 225*225*80 | 935 | 80 | 64 | 2550 | - | |
![]() W2E200-HH38-06 | ebm-papst 230V 80W AC Axial Fan for New Energy Cooling Created for New Energy Cooling, ebm-papst W2E200-HH38-06 is a 230 V AC axial fan, using 200 mm dimensions for installation planning. The value helps verify equipment fit. Its documented data supports integration planning. |
230 | 200 | 1045 | 90 | 80 | 2800 | - | |
![]() W2E200-HH38-05 | ebm-papst 230V 85W AC Axial Fan for New Energy Cooling Configured for New Energy Cooling, ebm-papst W2E200-HH38-05 is a 230 V AC axial fan, featuring a listed acoustic value of 61 dB. It supports replacement and design review. Its documented data supports integration planning. |
230 | 225*225*80 | 935 | 120 | 85 | 2800 | 61 | |
![]() W2E200-HH38-01 | ebm-papst 230V 64W AC Axial Fan for New Energy Cooling Chosen for New Energy Cooling, ebm-papst W2E200-HH38-01 is a 230 V AC axial fan, noted for 200 mm dimensions for installation planning. The data supports model-level evaluation. Its documented data supports integration planning. |
230 | 200 | 935 | 180 | 64 | 2550 | - | |
![]() W2E142-BB01-01 | ebm-papst 230V 27W AC Axial Fan for New Energy Cooling Supporting New Energy Cooling, ebm-papst W2E142-BB01-01 is a 230 V AC axial fan, with a documented 27 W input rating. It provides a practical sizing reference. Its documented data supports integration planning. |
230 | 150φ*38 | 320 | 50 | 27 | 2830 | - | |
![]() W1G200-HH77-52 | ebm-papst 24V 55W EC Axial Fan for New Energy Cooling Configured for New Energy Cooling, ebm-papst W1G200-HH77-52 is a 24 V EC axial fan, featuring a documented 55 W input rating. This guides model-to-system comparison. Its documented data supports integration planning. |
24 | 225*225*80 | - | 110 | 55 | 2950 | - | |
![]() K2E225-RA92-09 | ebm-papst 230V 210W AC Centrifugal Fan for Energy Storage Aimed at Energy Storage, the ebm-papst K2E225-RA92-09 is a 230 V AC backward-curved centrifugal fan, identified by a documented speed of 2,700 rpm. It gives engineers a clear comparison point. |
230 | 225 | 1300 | 200 | 210 | 2700 | 64 | |
![]() K2E250-AH06-06 | ebm-papst 230V AC Centrifugal Fan for Energy Storage Systems Specified for Energy Storage Systems, the ebm-papst K2E250-AH06-06 is a 230 V AC backward-curved centrifugal fan, noted for 250 mm dimensions for installation planning. The data supports model-level evaluation. |
230 | 250 | - | - | - | - | - | |
![]() K2E200-AA52-02 | ebm-papst 230V 90W AC Centrifugal Fan for Energy Storage Engineered around Energy Storage, the ebm-papst K2E200-AA52-02 is a 230 V AC backward-curved centrifugal fan, distinguished by a documented speed of 2,950 rpm. This helps evaluate the intended duty. |
230 | 200 | 850 | 245 | 90 | 2950 | 65 | |
![]() K2E225-RA92-01 | ebm-papst 230V 210W AC Centrifugal Fan for Energy Storage Prepared for Energy Storage, the ebm-papst K2E225-RA92-01 is a 230 V AC backward-curved centrifugal fan, with a focus on a listed pressure capability of 500 Pa. It gives engineers a clear comparison point. |
230 | 225 | 1300 | 500 | 210 | 2600 | 64 | |
![]() K2E250-RA50-11 | ebm-papst 230V 285W AC Centrifugal Fan for Energy Storage Used in Energy Storage, the ebm-papst K2E250-RA50-11 is a 230 V AC backward-curved centrifugal fan, rated with a listed pressure capability of 600 Pa. This helps guide installation planning. |
230 | 250 | 1500 | 600 | 285 | 2450 | 61 | |
![]() K2E225-RA40-02 | ebm-papst 115V 165W AC Centrifugal Fan for Energy Storage Built for Energy Storage, the ebm-papst K2E225-RA40-02 is a 115 V AC backward-curved centrifugal fan, for which the table lists a documented 165 W input rating. This supports technical purchasing review. |
115 | 225 | - | - | 165 | 2550 | - | |
![]() K2E250-RA50-01 | ebm-papst 230V 285W AC Centrifugal Fan for Energy Storage Suited to Energy Storage, the ebm-papst K2E250-RA50-01 is a 230 V AC backward-curved centrifugal fan, noted for a listed acoustic value of 61 dB. The figure helps confirm design suitability. |
230 | 250 | 1045 | 250 | 285 | 2450 | 61 | |
![]() K2E225-AB92-09 | ebm-papst 230V 220W AC Centrifugal Fan for Energy Storage Deployed in Energy Storage, the ebm-papst K2E225-AB92-09 is a 230 V AC backward-curved centrifugal fan, featuring a documented speed of 2,750 rpm. This guides model-to-system comparison. |
230 | 225 | 980 | - | 220 | 2750 | - |
The most reliable way to specify new Energy is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,013 products are available in this category today.
The daily work of our sales engineers is built around new Energy used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.