| Mfr Part # | Rated Voltage(V) | Size(mm) | Max.Air Flow(m³/h) | Max.Pressure(Pa) | Input Power(W) | Speed(rpm) | Noise(db) | |
|---|---|---|---|---|---|---|---|---|
![]() ER50C-4DN.G7.1R 130579/0F41 | ZIEHL-ABEGG 400VAC 5500W AC Centrifugal Fan for renewable energy ER50C-4DN.G7.1R 130579/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 86 dB noise data recorded for this model. It also lists a 500 mm size specified in the upload data. Review acoustic limit for cabinet planning. |
400 | 500 | 9900 | 1325 | 5500 | 2210 | 86 | |
![]() ER50C-4DN.G7.1R 130578/0F41 | ZIEHL-ABEGG 400VAC 4000W AC Centrifugal Fan for renewable energy ER50C-4DN.G7.1R 130578/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is a 500 mm size specified in the upload data. It also lists 4000 W input power for the listed electrical version. Review control method for cabinet planning. |
400 | 500 | - | - | 4000 | - | - | |
![]() ER50C-4DN.F7.1R 130577/0F41 | ZIEHL-ABEGG 400VAC 3000W AC Centrifugal Fan for renewable energy ER50C-4DN.F7.1R 130577/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is a compact construction intended to simplify equipment integration. It also lists a 500 mm size specified in the upload data. Review electrical supply for cabinet planning. |
400 | 500 | - | - | 3000 | - | - | |
![]() ER50C-4DN.E7.1R 130576/0F41 | ZIEHL-ABEGG 400VAC 2200W AC Centrifugal Fan for renewable energy ER50C-4DN.E7.1R 130576/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 750 Pa maximum pressure stated for this model. It also lists a 500 mm size specified in the upload data. Review motor interface for cabinet planning. |
400 | 500 | 7300 | 750 | 2200 | 1640 | 79 | |
![]() ER50C-4DN.D7.1R 130575/0F41 | ZIEHL-ABEGG 400VAC 1500W AC Centrifugal Fan for renewable energy ER50C-4DN.D7.1R 130575/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 6500 m³/h maximum airflow stated for this model. It also lists a 500 mm size specified in the upload data. Review pressure requirement for cabinet planning. |
400 | 500 | 6500 | 575 | 1500 | 1450 | 77 | |
![]() ER45C-2DN.G7.1R 130588/0F41 | ZIEHL-ABEGG 400VAC 7500W AC Centrifugal Fan for renewable energy ER45C-2DN.G7.1R 130588/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is a 450 mm size specified in the upload data. It also lists 9400 m³/h maximum airflow stated for this model. Review airflow path for cabinet planning. |
400 | 450 | 9400 | 1825 | 7500 | 2950 | 91 | |
![]() ER45C-4DN.G7.1R 130587/0F41 | ZIEHL-ABEGG 400VAC 5500W AC Centrifugal Fan for renewable energy ER45C-4DN.G7.1R 130587/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is a compact construction intended to simplify equipment integration. It also lists a 450 mm size specified in the upload data. Review mounting envelope for cabinet planning. |
400 | 450 | 8600 | 1525 | 5500 | 2700 | 88 | |
![]() ER45C-4DN.F7.1R 130586/0F41 | ZIEHL-ABEGG 400VAC 4000W AC Centrifugal Fan for renewable energy ER45C-4DN.F7.1R 130586/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is a backward-curved impeller configuration. It also lists a 450 mm size specified in the upload data. Review procurement specification for motor selection. |
400 | 450 | 7700 | 1225 | 4000 | 2420 | 85 | |
![]() ER45C-4DN.E7.1R 130585/0F41 | ZIEHL-ABEGG 400VAC 3000W AC Centrifugal Fan for renewable energy ER45C-4DN.E7.1R 130585/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 83 dB noise data recorded for this model. It also lists a 450 mm size specified in the upload data. Review housing geometry for motor selection. |
400 | 450 | 7000 | 1000 | 3000 | 2190 | 83 | |
![]() ER45C-4DN.E7.1R 130584/0F41 | ZIEHL-ABEGG 400VAC 2200W AC Centrifugal Fan for renewable energy ER45C-4DN.E7.1R 130584/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 2020 rpm rated speed in the supplied parameter row. It also lists a 450 mm size specified in the upload data. Review controller compatibility for motor selection. |
400 | 450 | 6400 | 850 | 2200 | 2020 | 81 | |
![]() ER45C-4DN.D7.1R 130583/0F41 | ZIEHL-ABEGG 400VAC 1500W AC Centrifugal Fan for renewable energy ER45C-4DN.D7.1R 130583/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 1500 W input power for the listed electrical version. It also lists a 450 mm size specified in the upload data. Review air direction for motor selection. |
400 | 450 | 5600 | 625 | 1500 | 1760 | 78 | |
![]() ER45C-4DN.C7.1R 130582/0F41 | ZIEHL-ABEGG 400VAC 1100W AC Centrifugal Fan for renewable energy ER45C-4DN.C7.1R 130582/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 525 Pa maximum pressure stated for this model. It also lists a 450 mm size specified in the upload data. Review performance curve for motor selection. |
400 | 450 | 5000 | 525 | 1100 | 1580 | 75 | |
![]() ER40C-2DN.G7.1R 130594/0F41 | ZIEHL-ABEGG 400VAC 5500W AC Centrifugal Fan for renewable energy ER40C-2DN.G7.1R 130594/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 7000 m³/h maximum airflow stated for this model. It also lists a 400 mm size specified in the upload data. Review maintenance access for motor selection. |
400 | 400 | 7000 | 1950 | 5500 | 3340 | 89 | |
![]() ER40C-2DN.F7.1R 130593/0F41 | ZIEHL-ABEGG 400VAC 4000W AC Centrifugal Fan for renewable energy ER40C-2DN.F7.1R 130593/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is a 400 mm size specified in the upload data. It also lists 6300 m³/h maximum airflow stated for this model. Review equipment interface for motor selection. |
400 | 400 | 6300 | 1575 | 4000 | 3010 | 86 | |
![]() ER40C-4DN.E7.1R 130592/0F41 | ZIEHL-ABEGG 400VAC 3000W AC Centrifugal Fan for renewable energy ER40C-4DN.E7.1R 130592/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is a compact construction intended to simplify equipment integration. It also lists a 400 mm size specified in the upload data. Review ventilation duty for motor selection. |
400 | 400 | 5600 | 1225 | 3000 | 2690 | 84 | |
![]() ER40C-4DN.E7.1R 130591/0F41 | ZIEHL-ABEGG 400VAC 2200W AC Centrifugal Fan for renewable energy ER40C-4DN.E7.1R 130591/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is a backward-curved impeller configuration. It also lists a 400 mm size specified in the upload data. Review power budget for motor selection. |
400 | 400 | 5100 | 1000 | 2200 | 2430 | 81 | |
![]() ER40C-4DN.D7.1R 130590/0F41 | ZIEHL-ABEGG 400VAC 1500W AC Centrifugal Fan for renewable energy ER40C-4DN.D7.1R 130590/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 78 dB noise data recorded for this model. It also lists a 400 mm size specified in the upload data. Review fan selection for motor selection. |
400 | 400 | 4500 | 800 | 1500 | 2170 | 78 | |
![]() ER40C-4DN.C7.1R 130589/0F41 | ZIEHL-ABEGG 400VAC 1100W AC Centrifugal Fan for renewable energy ER40C-4DN.C7.1R 130589/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is a 400 mm size specified in the upload data. It also lists 1100 W input power for the listed electrical version. Review operating point for motor selection. |
400 | 400 | - | - | 1100 | - | - | |
![]() ER35C-2DN.F7.1R 130598/0F41 | ZIEHL-ABEGG 400VAC 4000W AC Centrifugal Fan for renewable energy ER35C-2DN.F7.1R 130598/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 4000 W input power for the listed electrical version. It also lists a 355 mm size specified in the upload data. Review installation clearance for motor selection. |
400 | 355 | 5200 | 1850 | 4000 | 3650 | 88 | |
![]() ER35C-2DN.E7.1R 130597/0F41 | ZIEHL-ABEGG 400VAC 3000W AC Centrifugal Fan for renewable energy ER35C-2DN.E7.1R 130597/0F41 is a 400 VAC centrifugal fan for data centers, air-conditioning systems, marine systems. Its main supplied feature is 1600 Pa maximum pressure stated for this model. It also lists a 355 mm size specified in the upload data. Review wiring plan for motor selection. |
400 | 355 | 4700 | 1600 | 3000 | 3330 | 85 |
The most reliable way to specify new Energy is to work from the system, not from the catalog. Measure or calculate the airflow and pressure demand first, add the dimensional limits of the mounting position, and only then shortlist series whose curves cover your operating point with margin.
Electrical matching is the next gate. Confirm the supply voltage — 12 V, 24 V or 48 V DC for compact electronics cooling, 115 V or 230 V AC for equipment and panel cooling — and decide whether you need speed control. EC models accept PWM or 0-10 V signals and report speed through a tachometer output, which makes them the default choice for variable-airflow systems, while AC units remain a cost-effective answer for fixed-speed duty.
Then filter by environment. High ambient temperature, dust or moisture loads dictate the IP rating and bearing choice — ball bearings keep airflow and noise stable over years, while sleeve bearings suit light-duty horizontal mounting. Regulatory needs such as UL, CE and RoHS recognition should be confirmed before the shortlist goes to purchasing, together with a maximum allowed sound pressure level in dBA.
End the process by checking supply, not just specification: confirm current stock, the lead time for follow-up quantities, and obtain datasheets and dimension drawings so the mechanical interface is verified before the PO. Send us your airflow and pressure requirements and our engineers will confirm the best-matched series — 1,013 products are available in this category today.
The daily work of our sales engineers is built around new Energy used in data center cooling, refrigeration and cold chain projects, building ventilation, telecom base stations, medical devices and industrial control cabinets — environments where a stopped fan is a stopped business process. That daily exposure to real installations is exactly what we bring back into every selection: not just reading curves, but knowing which models survive dust, heat, continuous duty and restricted service access.
A typical case: an equipment builder needed to replace an aging AC fan inside a control cabinet that could not be taken offline for more than an hour. By cross-referencing the frame dimensions, voltage and airflow curve, we supplied a current-series drop-in replacement with a matching tachometer signal, and the swap was completed during a scheduled maintenance window.
Refrigeration and cold chain customers bring us another pattern: the failed condenser fan is unavailable for weeks. Comparing diameter, speed, bearings and IP rating, we supply a functionally equivalent unit from stock so the system returns to duty the same week — the reason many service companies keep our contact number on file.
From one-piece emergency replacements to volume supply for equipment manufacturers, every enquiry is handled by the same rule: verify the parameters first, then quote — so what arrives on site is the fan the project actually needs.
Single-piece orders and samples are welcome — many customers validate one unit in their system before committing to volume. There is no minimum order quantity for standard stock models, and the sample price is deducted from the bulk order in most repeat purchases. Tell us the quantity you plan to use and we will quote both scenarios.
Yes. Beyond catalogue models we can discuss modified lead wires, connectors, speed curves, IP upgrades or private-label packaging for OEM projects. Customization usually starts from a defined annual quantity; our engineers will review your requirement and confirm feasibility, tooling cost and lead time before any commitment.
Every unit is covered by the manufacturer's warranty against defects in materials and workmanship, and we support you through the whole claim process so you deal with one supplier instead of chasing a factory overseas. If a failure appears in service, send us the serial number, operating conditions and photos, and we will arrange the replacement or credit path agreed in the quotation.
Bag
Bag packaging indicates that a specified quantity of product is packaged by the manufacturer in a bag, sealed pouch, or similar container and sold as a unit without repackaging. It is also used to describe kits/assortments where components are packaged in separate bags according to part number or parametric value, rather than in a compartmentalized box or similar rigid container.