4414/2H is a 24 VDC compact axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is 4300 rpm rated speed in the supplied parameter row. It also lists a 120*120*38 mm size specified in the upload data. Review service access for replacement review.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 120*120*38 |
| Max.Air Flow(m³/h) | 240 |
| Max.Pressure(Pa) | 160 |
| Input Power(W) | 8..6 |
| Speed(rpm) | 4300 |
The ebm-papst 4414/2H aids data centers and communication equipment as a DC tightly packaged axial fan, combining a tightly packaged thermal management role with a clear mechanical and electrical integration path.
The design aids integration near sensitive assemblies where predictable air delivery and minimal space claim are important.
Equipment platform validation should include realistic filters, grilles and neighboring components because these elements influence delivered air delivery.
Listed air delivery of 240 m3/h and pressure of 160 Pa provide starting points for duty-point evaluation in the completed equipment platform. Preserve the specified air delivery direction during assembly. Review the approved electrical interface for the complete suffix.
Within servers and data-communication hardware, 4414/2H cools computing and network assemblies as a ebm-papst DC space-conscious axial fan. This gives equipment makers a practical thermal management element that helps maintain unit reliability without changing the stated industry direction.
4414/2H helps maintain power supplies, inverters and control cabinets by using its DC space-conscious axial fan format to cools power modules and controls. The installation benefits from continuous heat removal where passive temperature management alone cannot maintain design margin.
OEM designs for industrial automation installation use 4414/2H where a DC space-conscious axial fan must ventilates drives and production electronics. The final temperature management flow path should remain clear during installation and routine maintenance.
For equipment in medical and laboratory instruments, ebm-papst 4414/2H acts as a thermal control component that cools enclosed instrument electronics. The equipment benefits from continuous heat removal where passive thermal control alone cannot maintain design margin.
Confirm the target equipment, operating point, ambient conditions, installation space, electrical supply, controls, protection, quantity, and required delivery date.
The product is classified as a compact axial fan. Use the full model code because nearby variants can differ in motor, mounting, and controls.
No exact IP protection level is stated for this item in the supplied sources. Confirm it before use in dusty, wet, or harsh locations.
Speed-control support is not stated for this exact item in the supplied sources. Confirm the motor and controller version before specifying control hardware.
No guaranteed lead time is provided in the supplied sources. Confirm current stock, required quantity, production schedule, and shipping date with the supplier.
The supplied sources do not confirm an integrated controller. Verify the exact electrical variant and control requirement before ordering.

HA40101V4-1000U-A99 is a 12 VDC axial fan for servers, data-communications equipment, control cabinets. Its main supplied feature is axial airflow intended for low-to-moderate system resistance. It also lists a 40*40*10 mm size specified in the upload data. Review acoustic limit for replacement review.
Read More
The HA40201V4-10000-A99 is SUNON's 12 VDC, 40 × 40 × 20 mm DC axial fan option for telecom cabinets, base stations, and network equipment. A listed noise value of 12.3 dB is the model's key differentiator. For reliability evaluation, start with the supplied operating point. Treat bearing and life data as suffix-specific.
Read More
SUNON configures HA40101V4-10000-A99 as a 40 × 40 × 10 mm DC axial fan for telecom cabinets, base stations, and network equipment, operating at 12 VDC. A listed noise value of 15.7 dB is the model's key differentiator. Use the documented pressure capability when planning reliability evaluation. Treat bearing and life data as suffix-specific.
Read More
Used in servers and data-center electronics, SUNON HA40101V4-1D070-G99 is a 12 VDC DC axial fan in a 40 × 40 × 10 mm frame. A listed noise value of 15.7 dB is the model's key differentiator. Treat the acoustic value as a primary input to reliability evaluation. Treat bearing and life data as suffix-specific.
Read More
Designed for telecom cabinets, base stations, and network equipment, SUNON HA40101V4-1000U-999 is a 12 VDC DC axial fan in a 40 × 40 × 10 mm frame. A listed noise value of 15.7 dB is the model's key differentiator. The recorded cooling specification should guide airflow-path design. Obtain the applicable curve before final duty-point approval.
Read More
The HA40101V4-1000U-A99 is SUNON's 12 VDC, 40 × 40 × 10 mm DC axial fan option for telecom cabinets, base stations, and network equipment. A listed noise value of 15.7 dB is the model's key differentiator. The recorded acoustic value should guide enclosure sizing. Verify bearing and signal options in the exact datasheet.
Read More