For hvac/r, the ebm-papst A4D350-AP08-16 provides a 400 V AC axial fan solution. Performance data of 3280 m³/h airflow, 90 Pa pressure, 1410 RPM supports practical selection for continuous ventilation, component cooling and replacement planning.
| Rated Voltage(V) | 400 |
|---|---|
| Size(mm) | 350 |
| Max.Air Flow(m³/h) | 3280 |
| Max.Pressure(Pa) | 90 |
| Input Power(W) | 130 |
| Speed(rpm) | 1410 |
The ebm-papst A4D350-AP08-16 is an AC axial fan for industrial equipment cooling, delivering directed airflow for machinery, motor systems and ventilation assemblies.
Data includes 400 V operation, airflow up to 3280 m³/h and pressure up to 90 Pa for matching airflow to system resistance. The datasheet lists ball-bearing support for durable motor support. Installed noise depends on the duty point and airflow path. Correct electrical selection and clear inlet spacing support efficient cooling, reliable operation and long fan life.
Suitable for OEM engineers, manufacturers and maintenance buyers, the A4D350-AP08-16 should be checked for wiring, mounting, duty point and ambient limits before selection.
How the A4D350-AP08-16 compares to nearby A4D series variants:
| Model | A4D500-AJ03-01 | A4D500-AM03-01 | A4D500-AM03-02 | A4D560-AM03-01 |
|---|---|---|---|---|
| Air Flow | 9030 m³/h | 10920 m³/h | 10920 m³/h | 12600 m³/h |
| Power | 710 W | 1060 W | 1060 W | 1160 W |
| Noise | 64 dB | 68 dB | 68 dB | 74 dB |
| Size | 500 mm | 500 mm | 500 mm | 560 mm |
All A4D series fans from Hengrui include performance curves, mounting instructions and factory warranty. Contact us for project-specific selection.
Condenser Cooling: The A4D350-AP08-16 axial fan excels at condenser heat rejection in refrigeration and HVAC.
AHU Air Handling: Engineered for integration into Air Handling Units.
Industrial Process Ventilation: Machinery cooling, enclosure ventilation and process air movement. Hengrui provides custom engineering support.
The product workbook lists RoHS Compliant. Request the exact-model compliance document when formal evidence is required.
Correct sizing and unobstructed airflow can reduce avoidable thermal stress; verify performance at the real operating point before purchase.
It is suited to 制冷; confirm airflow, space and electrical requirements before selection.

A4E350-AP06-33 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 3110 m³/h maximum airflow stated for this model. It also lists a 350 mm size specified in the upload data. Review ventilation duty for air-system design.
Read More
A4E400-AP02-01 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is a 400 mm size specified in the upload data. It also lists 4950 m³/h maximum airflow stated for this model. Review housing geometry for compatibility checking.
Read MoreA4E450-AP01-01 is a 230 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 355 W input power for the listed electrical version. It also lists a 450 mm size specified in the upload data. Review controller compatibility for compatibility checking.
Read More
Used in HVAC Ventilation, ebm-papst A2D300-AP02-02 is a 400 V AC axial fan, defined by a listed airflow of 3,350 m³/h. The data helps compare W-series variants. Its documented data supports integration planning.
Read More
A6D800-AA01-01 is a 400 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is a 800 mm size specified in the upload data. It also lists 180 Pa maximum pressure stated for this model. Review maintenance access for ductwork design.
Read More
A6D800-AE05-03 is a 480 VAC axial fan for data-communications equipment, heat pumps, ventilation systems. Its main supplied feature is 25190 m³/h maximum airflow stated for this model. It also lists a 800 mm size specified in the upload data. Review maintenance access for air-system design.
Read More