Home > Products > By type > Axial Fans > 109P0424H3013 | Sanyo Denki 24VDC 2.28W DC Axial Fan for UPS, server and telecom equipment cooling

109P0424H3013 Sanyo Axial Fan

Brand :
Sanyo
Model:
109P0424H3013 | Sanyo Denki 24VDC 2.28W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

The 40 × 40 × 28 mm Sanyo Denki 109P0424H3013 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Review its thermal-duty record during thermal validation. Match the exact part number before approving a substitute. Focus: acoustic limit assessment speed benchmark.

Datasheet:
109P0424H3013 | Sanyo Denki 24VDC 2.28W DC Axial Fan for UPS, server and telecom equipment cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)24
Size(mm)40*40*28
Max.Air Flow(m³/h)19.21
Max.Pressure(Pa)102.9
Input Power(W)2.28
Speed(rpm)8700
Noise(db)37

Product Features

Efficient Cooling

The SANYO DENKI 109P0424H3013 is a DC axial fan developed for servers, storage systems and ICT equipment. Its directed airflow helps remove heat from densely arranged components and supports predictable equipment temperatures.

With up to 19.21 m3/h airflow and 102.9 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Test component temperatures at peak load. This confirms cooling margin before volume production. Confirm the final fan curve in the assembled equipment.

Application Industry

Frequently Asked Questions

Can 109P0424H3013 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

What input power is listed for 109P0424H3013?

The worksheet lists 2.28 W. Check supply capacity and operating conditions before commissioning.

What should be checked if 109P0424H3013 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

Is 109P0424H3013 easy to install and maintain?

Confirm connector and mounting details, keep the airflow path clear, and isolate power before cleaning or service.

Which specifications define 109P0424H3013?

Use rated voltage, 40 × 40 × 28 mm dimensions, 19.21 m³/h airflow, 8700 rpm, and 2.28 W input for preliminary comparison.

What equipment is 109P0424H3013 suited to?

It is listed for servers, UPS systems, and telecom equipment. Confirm airflow, pressure, dimensions, and environmental conditions against the actual equipment.