Get Quote
Home > Products > By type > Axial Fans > 109P0424H601 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling

109P0424H601 Sanyo Axial Fan

Brand :
Sanyo
Model:
109P0424H601 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

The 40 × 40 × 20 mm Sanyo Denki 109P0424H601 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. For replacement evaluation, start with the supplied thermal-duty record. Treat bearing and life data as suffix-specific. Focus: compatibility risk checking frame geometry.

Datasheet:
109P0424H601 | Sanyo Denki 24VDC 1.68W DC Axial Fan for UPS, server and telecom equipment cooling Datasheet (Pdf)

Product Features

Rated Voltage(V)24
Size(mm)40*40*20
Max.Air Flow(m³/h)13.8
Max.Pressure(Pa)69.7
Input Power(W)1.68
Speed(rpm)8300
Noise(db)35

Product Features

Stable San Ace Fan

For servers, storage systems and ICT equipment, the SANYO DENKI 109P0424H601 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.

With up to 13.8 m3/h airflow and 69.7 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. OEM qualification should check startup demand, installation orientation and the exact electrical interface. Installed sound and airflow depend on the surrounding cabinet structure.

Measure installed sound in the final cabinet. It gives integrators a practical acceptance criterion. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.

Application Industry

Frequently Asked Questions

Does 109P0424H601 have a pressure rating?

The worksheet lists 69.7 Pa. Use the official curve to match it to system resistance.

What certifications apply to 109P0424H601?

The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

Can 109P0424H601 replace another fan directly?

Match voltage, size, mounting, airflow direction, airflow, pressure, connector, control signal, and protection before substitution.

What airflow is listed for 109P0424H601?

The worksheet lists 13.8 m³/h. Compare the operating point with system resistance and the official performance curve.

What is the lead time for 109P0424H601?

Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.

How noisy is 109P0424H601?

The worksheet lists 35 dB. Enclosure acoustics, system resistance, and distance can change the installed result.

Message Form