



Sanyo Denki configures 9G0824H1D01 for servers, UPS systems, and telecom equipment as a 24 VDC DC axial fan with 80 × 80 × 38 mm dimensions. 10.1 W input is the defining electrical-load figure. Base cabinet ventilation planning on the stated acoustic value. Use current model documentation to validate protection choices.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 80*80*38 |
| Max.Air Flow(m³/h) | 134.4 |
| Max.Pressure(Pa) | 171.1 |
| Input Power(W) | 10.1 |
| Speed(rpm) | 5700 |
| Noise(db) | 49 |
9G0824H1D01 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
Its 134.4 m3/h maximum airflow supports rapid air exchange, while 171.1 Pa pressure capability helps overcome resistance within the finished equipment. Buyers should confirm the complete suffix, connector, sensor output and control option before ordering. Engineers should validate the operating point with the actual grille and filter.
Check startup demand against the power supply. It gives integrators a practical acceptance criterion. Confirm the final fan curve in the assembled equipment.
SANYO DENKI 9G0824H1D01 serves server chassis and computing nodes that operate with sustained internal heat. Directed airflow carries component heat toward the equipment exhaust and helps maintain a controlled internal temperature. The application supports stable equipment service.
9G0824H1D01 is suitable for storage arrays and data appliances. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 9G0824H1D01 supports thermal management in network and other ICT hardware. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
The worksheet lists 171.1 Pa. Use the official curve to match it to system resistance.
Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.
Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.
The worksheet lists 134.4 m³/h. Compare the operating point with system resistance and the official performance curve.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

Aimed at Boiler Systems, the ebm-papst G1G146-BA07-52 is a 24 V EC backward-curved centrifugal fan, for which the table lists a listed pressure capability of 500 Pa. This assists electrical and mechanical review.
Read More
Integrated into Boiler Systems, the ebm-papst G1G133-DE19-15 is a 24 V EC backward-curved centrifugal fan, specified with a documented 45 W input rating. The rating aids system-fit checks.
Read More
Suited to Boiler Systems, ebm-papst G1G097-AA05-01 is a 24 V EC backward-curved centrifugal fan, marked by a documented 16 W input rating. It provides a practical sizing reference.
Read More
In inverter cooling, G2D180-BD18-13 serves as a 400 V AC centrifugal blower. Its standout data point is 840 Pa pressure with IP00 protection. It supports exact-model comparison for OEM sourcing and replacement work.
Read More
G2D180-BD18-11 is specified as a 400 V AC centrifugal blower for cnc machines. Its selection profile is led by 700 Pa pressure with 2,650 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work.
Read More
Designed around motor cooling, G2D160-AF02-09 uses a 230 V AC centrifugal blower platform. The model's defining specification is IP44 protection with 2,300 rpm operation. It supports exact-model comparison for OEM sourcing.
Read More