The 92 × 92 × 32 mm Sanyo Denki 9G0924A2D01 brings 24 VDC DC axial fan cooling to servers, UPS systems, and telecom equipment. Series focus: high airflow and pressure. Base wiring review on the stated electrical load. Review connector, alarm, and sensor options separately. Focus: resistance curve checking sound level.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 92*92*32 |
| Max.Air Flow(m³/h) | 150 |
| Max.Pressure(Pa) | 115 |
| Input Power(W) | 7.2 |
| Speed(rpm) | 4300 |
| Noise(db) | 44 |
For servers, storage systems and ICT equipment, the SANYO DENKI 9G0924A2D01 provides DC axial fan cooling in an integration-ready format. It establishes an active air path through restricted equipment spaces.
With up to 150 m3/h airflow and 115 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Preserve outlet space to limit recirculation. This confirms cooling margin before volume production. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
The San Ace 9G0924A2D01 supports thermal management in server chassis and computing nodes. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It supports reliable OEM equipment cooling.
For storage arrays and data appliances, 9G0924A2D01 provides a dedicated forced-air cooling path. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It supports reliable OEM equipment cooling.
SANYO DENKI 9G0924A2D01 serves network and other ICT hardware that operate with sustained internal heat. These systems need continuous heat removal because compact layouts and rising power density restrict natural convection. It supports reliable OEM equipment cooling.
Availability and lead time can change. Confirm the exact suffix, quantity, and delivery date with the supplier before ordering.
The worksheet lists 24 VDC. Check polarity or AC frequency and the wiring diagram before commissioning.
The listed speed is 4300 rpm. Confirm control conditions and the actual duty point.
Confirm full suffix, voltage, connector, control signal, bearing, IP rating, certifications, stock, and required delivery date.
Use rated voltage, 92 × 92 × 32 mm dimensions, 150 m³/h airflow, 4300 rpm, and 7.2 W input for preliminary comparison.
The workbook marks it RoHS compliant. Confirm model-specific UL, CSA, TÜV, or other required approvals from official documentation.

Aimed at Boiler Systems, the ebm-papst G1G146-BA07-52 is a 24 V EC backward-curved centrifugal fan, for which the table lists a listed pressure capability of 500 Pa. This assists electrical and mechanical review.
Read More
Integrated into Boiler Systems, the ebm-papst G1G133-DE19-15 is a 24 V EC backward-curved centrifugal fan, specified with a documented 45 W input rating. The rating aids system-fit checks.
Read More
Suited to Boiler Systems, ebm-papst G1G097-AA05-01 is a 24 V EC backward-curved centrifugal fan, marked by a documented 16 W input rating. It provides a practical sizing reference.
Read More
In inverter cooling, G2D180-BD18-13 serves as a 400 V AC centrifugal blower. Its standout data point is 840 Pa pressure with IP00 protection. It supports exact-model comparison for OEM sourcing and replacement work.
Read More
G2D180-BD18-11 is specified as a 400 V AC centrifugal blower for cnc machines. Its selection profile is led by 700 Pa pressure with 2,650 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work.
Read More
Designed around motor cooling, G2D160-AF02-09 uses a 230 V AC centrifugal blower platform. The model's defining specification is IP44 protection with 2,300 rpm operation. It supports exact-model comparison for OEM sourcing.
Read More