Get Quote
Home > Products > By type > Axial Fans > 9G1212H101 | Sanyo Denki 12VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling

9G1212H101 Sanyo Axial Fan

Brand :
Sanyo
Model:
9G1212H101 | Sanyo Denki 12VDC 4.56W DC Axial Fan for UPS, server and telecom equipment cooling
Type:
Axial Fans
Industry:
Data Center Cooling
Description:

Sanyo Denki configures 9G1212H101 for servers, UPS systems, and telecom equipment as a 12 VDC DC axial fan with 120 × 120 × 38 mm dimensions. Its 2600 rpm rating defines a lower-speed operating point. Base service-life planning on the stated catalog specification. Confirm control inputs against the complete ordering code.

Product Features

Rated Voltage(V)12
Size(mm)120*120*38
Max.Air Flow(m³/h)168.3
Max.Pressure(Pa)70.5
Input Power(W)4.56
Speed(rpm)2600
Noise(db)39

Product Features

Stable San Ace Fan

9G1212H101 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.

With up to 168.3 m3/h airflow and 70.5 Pa static pressure, the model can move cooling air through vents, filters and compact internal passages. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.

Check exhaust separation from the intake zone. This improves consistency between prototype and production. Confirm the final fan curve in the assembled equipment.

Application Industry

Frequently Asked Questions

Is 9G1212H101 suitable for high-reliability cooling?

Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.

Which application details matter most for 9G1212H101?

Review ambient temperature, airflow restriction, contamination exposure, noise limit, mounting orientation, and maintenance access.

What airflow is listed for 9G1212H101?

The worksheet lists 168.3 m³/h. Compare the operating point with system resistance and the official performance curve.

Can 9G1212H101 reduce total operating cost?

Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

How noisy is 9G1212H101?

The worksheet lists 39 dB. Enclosure acoustics, system resistance, and distance can change the installed result.

What should be checked if 9G1212H101 stops?

Verify supply, connector, obstructions, impeller movement, and alarm or protection status using the model-specific troubleshooting data.

Message Form