9G1212H401 addresses servers, UPS systems, and telecom equipment through a 12 VDC DC axial fan platform measuring 120 × 120 × 25 mm. Series focus: high airflow and pressure. Its 2850 rpm rating defines a lower-speed operating point. Check cabinet ventilation planning system interface. Focus: cabinet ventilation planning system interface.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 120*120*25 |
| Max.Air Flow(m³/h) | 149.6 |
| Max.Pressure(Pa) | 210 |
| Input Power(W) | 3.72 |
| Speed(rpm) | 2850 |
| Noise(db) | 40 |
The San Ace 9G1212H401 serves servers, storage systems and ICT equipment as a DC axial fan. Its airflow supports heat transfer from internal devices toward cabinet or chassis exhaust openings.
A listed maximum airflow of 149.6 m3/h and maximum pressure of 210 Pa give engineers a clear basis for matching the fan to enclosure resistance. Selection should include a system-resistance review, mounting check and harness confirmation. The full model code matters because signal and lead options can differ within a series.
Test component temperatures at peak load. This gives purchasing a controlled replacement reference. Confirm the final fan curve in the assembled equipment. Preserve clear inlet and outlet space during installation.
9G1212H401 is suitable for server chassis and computing nodes. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It provides a practical cooling path for OEM integration. Selection should follow the approved full model code.
The San Ace 9G1212H401 supports thermal management in storage arrays and data appliances. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It provides a practical cooling path for OEM integration.
For network and other ICT hardware, 9G1212H401 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. It provides a practical cooling path for OEM integration.
Use rated voltage, 120 × 120 × 25 mm dimensions, 149.6 m³/h airflow, 2850 rpm, and 3.72 W input for preliminary comparison.
Evaluate the exact bearing, life, temperature, alarm, and protection data. Correct sizing and clean airflow are also required for reliable operation.
No exact IP rating is supplied for this model row. Check the current model datasheet before use in water, dust, or oil exposure.
PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.
Compare its listed power with the required airflow, pressure, and operating hours. System-level savings depend on correct duty-point selection.

Aimed at Boiler Systems, the ebm-papst G1G146-BA07-52 is a 24 V EC backward-curved centrifugal fan, for which the table lists a listed pressure capability of 500 Pa. This assists electrical and mechanical review.
Read More
Integrated into Boiler Systems, the ebm-papst G1G133-DE19-15 is a 24 V EC backward-curved centrifugal fan, specified with a documented 45 W input rating. The rating aids system-fit checks.
Read More
Suited to Boiler Systems, ebm-papst G1G097-AA05-01 is a 24 V EC backward-curved centrifugal fan, marked by a documented 16 W input rating. It provides a practical sizing reference.
Read More
In inverter cooling, G2D180-BD18-13 serves as a 400 V AC centrifugal blower. Its standout data point is 840 Pa pressure with IP00 protection. It supports exact-model comparison for OEM sourcing and replacement work.
Read More
G2D180-BD18-11 is specified as a 400 V AC centrifugal blower for cnc machines. Its selection profile is led by 700 Pa pressure with 2,650 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work.
Read More
Designed around motor cooling, G2D160-AF02-09 uses a 230 V AC centrifugal blower platform. The model's defining specification is IP44 protection with 2,300 rpm operation. It supports exact-model comparison for OEM sourcing.
Read More