The 9G1212P4H04 is a Sanyo Denki 12 VDC, 119 × 119 × 25 mm DC axial fan for servers, UPS systems, and telecom equipment. High airflow is highlighted together with a high-static-pressure design. Base duty-point matching on the stated power demand. Check the full suffix before confirming connector details. Focus: procurement data comparison.
| Rated Voltage(V) | 12 |
|---|---|
| Size(mm) | 119*119*25 |
| Max.Air Flow(m³/h) | 147.6 |
| Max.Pressure(Pa) | 64 |
| Input Power(W) | 3.72 |
| Speed(rpm) | 2850 |
| Noise(db) | 40 |
9G1212P4H04 brings San Ace DC axial fan cooling to servers, storage systems and ICT equipment. The compact air-moving design suits OEM assemblies that require continuous ventilation around electronic and power components.
A listed maximum airflow of 147.6 m3/h and maximum pressure of 64 Pa give engineers a clear basis for matching the fan to enclosure resistance. For design approval, verify airflow direction, connector details and available control signals. Prototype testing should include the final vents, guards and component loading.
Measure installed sound in the final cabinet. This gives purchasing a controlled replacement reference. Confirm the final fan curve in the assembled equipment.
9G1212P4H04 is suitable for server chassis and computing nodes. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service. Selection should follow the approved full model code.
The San Ace 9G1212P4H04 supports thermal management in storage arrays and data appliances. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
For network and other ICT hardware, 9G1212P4H04 provides a dedicated forced-air cooling path. Reliable ventilation reduces hot spots around sensitive electronics and supports consistent equipment availability. The application supports stable equipment service.
PWM or sensor functions depend on the exact suffix. Confirm the control lead and interface in the applicable Sanyo Denki datasheet.
Its 12 VDC rating and documented its 2850 rpm rating defines a lower-speed operating point. provide model-specific selection data without relying on unlisted claims.
The worksheet lists 3.72 W. Check supply capacity and operating conditions before commissioning.
Verify the exact bearing, rated life, temperature range, and duty limits. The supplied family description alone does not confirm continuous operation for every suffix.
The exact bearing is not stated in the supplied row. Confirm it from the complete model suffix and current Sanyo Denki datasheet.

Aimed at Boiler Systems, the ebm-papst G1G146-BA07-52 is a 24 V EC backward-curved centrifugal fan, for which the table lists a listed pressure capability of 500 Pa. This assists electrical and mechanical review.
Read More
Integrated into Boiler Systems, the ebm-papst G1G133-DE19-15 is a 24 V EC backward-curved centrifugal fan, specified with a documented 45 W input rating. The rating aids system-fit checks.
Read More
Suited to Boiler Systems, ebm-papst G1G097-AA05-01 is a 24 V EC backward-curved centrifugal fan, marked by a documented 16 W input rating. It provides a practical sizing reference.
Read More
In inverter cooling, G2D180-BD18-13 serves as a 400 V AC centrifugal blower. Its standout data point is 840 Pa pressure with IP00 protection. It supports exact-model comparison for OEM sourcing and replacement work.
Read More
G2D180-BD18-11 is specified as a 400 V AC centrifugal blower for cnc machines. Its selection profile is led by 700 Pa pressure with 2,650 rpm operation. It supports exact-model comparison for OEM sourcing and replacement work.
Read More
Designed around motor cooling, G2D160-AF02-09 uses a 230 V AC centrifugal blower platform. The model's defining specification is IP44 protection with 2,300 rpm operation. It supports exact-model comparison for OEM sourcing.
Read More