Applied in servers and data-center electronics, SUNON GF40282B2-10000-QDP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 13100 W input is the defining electrical load in the supplied data. During cooling-margin review, compare the model's acoustic value. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40x40x28mm |
| Max.Air Flow(m³/h) | 31.1 |
| Max.Pressure(Pa) | 281.5 |
| Input Power(W) | 13100 |
| Speed(rpm) | 13100 |
| Noise(db) | 51.7 |
SUNON GF40282B2-10000-QDP brings active air movement to industrial equipment. This DC brushless axial fan helps equipment designers control thermal conditions around densely arranged parts.
The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling. Rigid mounting and clear breathing space help control vibration, flow loss and the acoustic result of the complete assembly.
GF40282B2-10000-QDP is best integrated with attention to grille resistance. Engineering teams can use replacement-fit checks before design lock to verify thermal suitability and give buyers an auditable selection basis. Account for the pressure loss introduced by guards and protective screens.
The supplied row does not state the connector or lead configuration. Follow the model-specific wiring drawing.
Inspect for dust, blocked airflow, abnormal noise, loose mounting, and wiring damage. Isolate power before cleaning or service.
Compare its listed 13100 W input with the required airflow and run time. Total savings depend on the complete system duty point.
The worksheet lists 51.7 dB. Installation distance, airflow resistance, and enclosure acoustics can change the measured result.
Verify supply, wiring, obstructions, impeller movement, and protection status. Use the model datasheet before replacement or repair.

GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
Read More
For thermal management in servers and data-center electronics, the GF40282B1-10000-QDP provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 14600 W input is the defining electrical load in the supplied data. Review its application data during cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.
Read More
Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON GF40282B2-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 13100 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated dimensional envelope. Check the full suffix before confirming connector details.
Read More