GF40282B3-10000-QDP addresses servers and data-center electronics through a 24 VDC DC axial fan platform measuring 40 × 40 × 28 mm. 10500 W input is the defining electrical load in the supplied data. Use the documented cooling output when planning cooling-margin review. Check the full suffix before confirming connector details.
| Rated Voltage(V) | 24 |
|---|---|
| Size(mm) | 40x40x28mm |
| Max.Air Flow(m³/h) | 25 |
| Max.Pressure(Pa) | 181.8 |
| Input Power(W) | 10500 |
| Speed(rpm) | 10500 |
| Noise(db) | 46.8 |
SUNON GF40282B3-10000-QDP is a DC brushless axial fan for industrial equipment. It establishes forced airflow where passive cooling cannot adequately protect heat-producing assemblies.
An airflow ceiling of 25 m3/h helps procurement teams compare models for the intended heat load. Actual cooling depends on how the installation guides air across components. The brushless DC motor architecture supports efficient electronic commutation and stable rotational performance for compact equipment cooling.
When qualifying GF40282B3-10000-QDP, give specific attention to service access. Use replacement-fit checks before design lock to align enclosure cooling, mechanical integration and lifecycle sourcing expectations. Retain access for inspection, cleaning and replacement after installation.
The worksheet lists up to 25 m³/h. Verify the operating point against system resistance.
Yes. The worksheet lists up to 181.8 Pa; compare it with the system curve.
Review its 40 × 40 × 28 mm size, 25 m³/h airflow, 181.8 Pa pressure, system resistance, and available mounting space.
It is listed for servers and data-center electronics. Check dimensions, airflow, pressure, and the installation environment against the actual equipment.
The exact IP or protection option is not stated in the supplied row. Confirm the full suffix in the applicable SUNON datasheet.

Applied in servers and data-center electronics, SUNON GF40282B2-10000-QDP is a 24 VDC DC axial fan in a 40 × 40 × 28 mm frame. 13100 W input is the defining electrical load in the supplied data. During cooling-margin review, compare the model's acoustic value. Check the full suffix before confirming connector details.
Read More
For thermal management in servers and data-center electronics, the GF40282B1-10000-QDP provides a 24 VDC DC axial fan configuration measuring 40 × 40 × 28 mm. 14600 W input is the defining electrical load in the supplied data. Review its application data during cabinet ventilation planning. Verify bearing and signal options in the exact datasheet.
Read More
Within servers and data-center electronics, SUNON GF40282B3-10000-SDP serves as a 40 × 40 × 28 mm DC axial fan operating at 24 VDC. 10500 W input is the defining electrical load in the supplied data. For cooling-margin review, start with the supplied frame geometry. Check the full suffix before confirming connector details.
Read More
The GF40282B3-10000-AEP is SUNON's 24 VDC, 40 × 40 × 28 mm DC axial fan option for servers and data-center electronics. Its 500 rpm rating defines a lower-speed operating point. Review its operating point during cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON configures GF40282B3-10000-ADP as a 40 × 40 × 28 mm DC axial fan for servers and data-center electronics, operating at 24 VDC. Its 500 rpm rating defines a lower-speed operating point. Treat the pressure capability as a primary input to cooling-margin review. Check the full suffix before confirming connector details.
Read More
SUNON GF40282B2-10000-SDP combines a 40 × 40 × 28 mm DC axial fan platform with a 24 VDC rating for servers and data-center electronics. 13100 W input is the defining electrical load in the supplied data. Base cooling-margin review on the stated dimensional envelope. Check the full suffix before confirming connector details.
Read More